Generators for Bahrain: 230/400 V, Heat and Salt Air

Diesel generators for Bahrain: 50 Hz, 230/400 V; heat, humidity and salt air on an island. Standby and prime sets for industry and buildings.

Terex Diesel containerised diesel generator

Request a quote

Contact us directly

Call +90 216 634 34 06WhatsApp +90 533 582 26 50

We reply in English.

Your request has been received. We will contact you as soon as possible.

Could not send. Please try again or call us. You can also reach us directly: WhatsApp +90 533 582 26 50 · info@terexdiesel.com

Too many submissions in a short time. Please try again in a few minutes.

Phone or email (one is enough)

Terms for sales outside Türkiye

  • Dispatch

    Models in stock: 2–3 business days; Perkins, Cummins, Volvo, Kubota, Scania and FPT Iveco: 3–4 weeks after order.

  • Warranty outside Türkiye

    12 months or 1,000 operating hours for all engine brands.

  • Certificates

    ISO 9001 · CE · TSE-HYB

  • Export documents

    A commercial invoice and packing list are prepared; a certificate of origin and any other documents the buyer requires are issued on request.

Export Process and Payment

Secure purchase process

From company verification to the loading video: every step in writing.

  1. Company verification
  2. Proforma invoice
  3. Order confirmation
  4. Live factory video call
  5. Your set’s serial number
  6. Pre-shipment inspection
  7. Signed test report
  8. Payment and loading approval
  9. Loading video and documents

See the full process

Bahrain is an island: almost every site is close to the sea. Summer temperatures regularly pass 40 °C, and the humidity stays high for much of the year. A generator here has to cope with three things at once: heat, moist air and salt. The public supply is 50 Hz, 230/400 V, the same frequency as the ratings in our catalogue.

Grid: 230/400 V, 50 Hz

The ratings in our catalogue are given for 50 Hz / 1,500 rpm, so they apply in Bahrain without conversion. The alternator is connected for a 400/230 V output, and the voltage is confirmed with the alternator data in the offer.

Some imported equipment packages are designed for 60 Hz, and some specifications ask for a set that can be switched between 50 and 60 Hz with a voltage selector. We offer these as options. At 60 Hz the set runs at 1,800 rpm, and its output is taken from the engine and alternator data sheets; see 50 Hz and 60 Hz generators.

Heat and humidity together

Hot air is thin; the engine takes in less oxygen and the radiator rejects less heat. We ask for the highest temperature at the installation point, not the city average, choose the radiator for it and move up one rating if needed. The logic is explained in power loss with temperature and altitude.

Many sets in Bahrain stand on roofs or in plant rooms. There the hot discharge air must not be drawn back into the intake, so the air inlet and outlet paths are separated.

Salt air on every site

On an island, salt is not only a coastal problem. We recommend corrosion-resistant surface protection for the canopy and base frame, and anti-condensation heaters for the alternator and the control panel. A standby set that sits idle in humid air should be run under load at regular intervals so that moisture does not settle in the windings.

Industrial and commercial use

  • Commercial buildings, hotels and hospitals: the generator backs up the grid; the ATS panel starts the set and transfers the load during an outage. Selection is made on standby power.
  • Industrial plants and workshops: where the set carries production loads for long hours, selection is made on prime power. Larger plants run two or more sets in parallel with a synchronization panel.
  • Construction sites and temporary power: prime power, sound-insulated canopy, and on request trailer-mounted generators and light towers.

Engine brand

The requests we receive from Bahrain usually name the engine brand, and often the alternator and controller as well. If your specification names a brand, we offer that brand. If it does not, we put the option that meets the specification at the lowest cost first and list the alternatives next to it. The models and ranges by brand are shown below.

Delivery and documents

Sets leave our factory in Tuzla, Istanbul, and travel to Bahrain by road or by sea; by sea, the usual port is Khalifa Bin Salman Port. The route depends on quantity and set size. Canopy sets are loaded on trucks or in containers, stretch-wrapped with edge protection; loose parts travel in crates or on pallets. The Incoterm is agreed in the offer, and transport is quoted as a separate line.

Each shipment goes with the commercial invoice, packing list, certificate of origin and factory test report. Any further conformity documents the importer needs are agreed at the quotation stage. For the other countries in the region, see Gulf countries.

For a quote

Power or a load list, standby or prime, 50 Hz or 60 Hz, the voltage, canopy or open type, panel (AMF, ATS, synchronization), fuel tank, the highest temperature at the installation point and whether the set stands on a roof, in a plant room or outdoors. Request a quote.

Suitable catalogue models

Market: Bahrain. Mains: 50 Hz, 230/400 V. The ratings below are the catalogue standby values at 50 Hz / 1,500 rpm; the voltage is confirmed with the alternator data in the offer.

Standby (kVA)ModelEngineDatasheet
110TRX CU ST 0110Cummins 6BTAA5.9G13PDF
110TRX P ST 0110Perkins 1104C-44TAG2PDF
200TRX CU ST 0200Cummins QSB6.7-G14PDF
250TRX P ST 0250Perkins 1206A-E70TTAG2PDF
400TRX BD ST 0400Baudouin 6M21G400/5PDF
440TRX VL ST 0440Volvo Penta TAD1344GEPDF
500TRX P ST 0500Perkins 2506A-E15TAG1PDF
550TRX CU ST 0550Cummins KTAA19-G10PDF

Each model page has the full technical data; where available, the datasheet (PDF) opens from the link in the table.

Engine brand options

The same rating can be offered with different engine brands. Catalogue ranges at 50 Hz (standby):

Test documents

Before shipment, every set is full-load tested on a load bank at our facility in Tuzla, with the load applied in steps. The test report records the product, engine and alternator serial numbers, the voltage, frequency and current measured at each load step, the function tests and the electrical safety tests. In the sample report the serial-number fields are blank; the actual report is issued with the numbers and signatures on delivery.

Generator sets being loaded onto a curtain-side trailerGenerator set being loaded with a forklift

Lead time, documents and warranty

Lead time
Sets with Quartz, SDEC and Baudouin engines: 1–3 weeks after order confirmation, depending on stock. Sets with Perkins, Cummins, Volvo Penta, Kubota, Scania and FPT Iveco engines: 3–4 weeks after order confirmation. Sets with Kofo or Yuchai engines: 1–2 weeks after order confirmation. Transport time is added and depends on the route.
Export documents
Each shipment goes with the datasheet, factory full-load test report, commercial invoice, packing list and certificate of origin. Other documents required in your country are prepared on request.
Warranty
12 months or 1,000 operating hours, for all engine brands.
Factory visit
You are welcome to visit our factory in Tuzla, Istanbul, to see production and the full-load test bench before you order. Contact us to arrange a date.

Gulf Countries

Request a quote for Bahrain

Tell us the power, duty, voltage, enclosure and panel you need, plus the site temperature and altitude, and we will work out the right configuration with you.

Request a Quote+90 216 634 34 06WhatsApp

Frequently asked questions

What voltage and frequency should a generator in Bahrain have?

The public supply in Bahrain is 50 Hz, 230/400 V: 400 V three-phase and 230 V single-phase. The 50 Hz / 1,500 rpm ratings in our catalogue apply directly, and the alternator is connected for 400/230 V. We confirm the voltage with the alternator data in the offer.

Can a set for Bahrain be supplied for 60 Hz or switchable 50/60 Hz?

Yes. Some equipment packages specify 60 Hz, or a set that can be switched between 50 and 60 Hz with a voltage selector. These are offered as options; the output at 60 Hz is taken from the engine and alternator data sheets, not from a fixed multiplier.

Standby or prime: which rating should be specified in Bahrain?

Where the generator backs up a building on the public grid, it is selected on its standby rating. On construction sites, temporary power and plants that run the set for long hours every day, it is selected on prime power. We state both ratings in the offer.

How are generators shipped from Türkiye to Bahrain?

By road or by sea; by sea, the usual port is Khalifa Bin Salman Port. The route depends on quantity and set size. Sets are loaded in containers or on trucks; the Incoterm (for example EXW Istanbul) is agreed in the offer and transport is quoted as a separate line. The set travels with the commercial invoice, packing list, certificate of origin and factory test report.

Send us your specification

Upload your tender or project specification. We review it the same day and send an offer package within 24 hours once the required information is complete.

Upload specification
Chat on WhatsApp