50 kVA (40 kW) Diesel Generator

This page lists 43 diesel generator models with standby ratings of 40–58 kVA (32–46.4 kW). Ratings listed: 40, 44, 46, 48, 50, 52, 55, and 58 kVA.

Get price and lead timeView models

Terex Diesel canopied diesel generator

Request a quote

Tell us your power requirement, duty (standby or prime) and delivery location, and we will prepare a quote for your project.

Contact us directly

Call +90 216 634 34 06WhatsApp +90 533 582 26 50

Your request has been received. We will contact you as soon as possible.

Could not send. Please try again or call us. You can also reach us directly: WhatsApp +90 533 582 26 50 · info@terexdiesel.com

Too many submissions in a short time. Please try again in a few minutes.

Phone or email (one is enough)

Terms for sales outside Türkiye

  • Dispatch

    Models in stock: 2–3 business days; Perkins, Cummins, Volvo, Kubota, Scania and FPT Iveco: 3–4 weeks after order.

  • Warranty outside Türkiye

    12 months or 1,000 operating hours for all engine brands.

  • Certificates

    ISO 9001 · CE · TSE-HYB

  • Export documents

    A commercial invoice and packing list are prepared; a certificate of origin and any other documents the buyer requires are issued on request.

Export Process and Payment

Key figures

Models
43
Standby power range
40–58 kVA
Engine brands
Perkins, Baudouin, Cummins, FPT Iveco, Kofo, Kubota, Quartz, Yangdong
Fuel consumption (75% load)
5.8–9.4 L/h
Weight with canopy
836–1,330 kg
Typical canopy dimensions (L × W × H)
2200 × 1000 × 1550 mm

Figures are calculated from the technical data of the models on this page; per-model values are on each product page.

Models rated 40–58 kVA standby

The table shows each model’s standby and prime ratings, engine and alternator; click a model name for full specifications. Use the compare button in the table to view models side by side.

Models rated 40–58 kVA standby
ModelStandby (kVA)Prime (kVA)EngineAlternatorFrequencyCompareView
TRX CU LS 00404035Cummins X2.7TAA-G8Leroy-Somer TAL042 F50 HzView: TRX CU LS 0040Request a Quote: TRX CU LS 0040
TRX CU MC 00404035Cummins X2.7TAA-G8Mecc Alte ECP32-2S/450 HzView: TRX CU MC 0040Request a Quote: TRX CU MC 0040
TRX CU ST 00404035Cummins X2.7TAA-G8Stamford S1L2J150 HzView: TRX CU ST 0040Request a Quote: TRX CU ST 0040
TRX CU TA 00404035Cummins X2.7TAA-G8Terex TA180-34N250 HzView: TRX CU TA 0040Request a Quote: TRX CU TA 0040
TRX YD TA 00404035Yangdong Y4102DTerex TA180-34N250 HzView: TRX YD TA 0040Request a Quote: TRX YD TA 0040
TRX BD MC 00444440Baudouin 4M06G8D0/SMecc Alte ECP32-2S/450 HzView: TRX BD MC 0044Request a Quote: TRX BD MC 0044
TRX BD ST 00444440Baudouin 4M06G8D0/SStamford S1L2-N50 HzView: TRX BD ST 0044Request a Quote: TRX BD ST 0044
TRX BD TA 00444440Baudouin 4M06G8D0/STerex TA180-34N250 HzView: TRX BD TA 0044Request a Quote: TRX BD TA 0044
TRX CU LS 00444440Cummins X2.7TAA-G8Leroy-Somer TAL042 F50 HzView: TRX CU LS 0044Request a Quote: TRX CU LS 0044
TRX CU MC 00444440Cummins X2.7TAA-G8Mecc Alte ECP32-2S/450 HzView: TRX CU MC 0044Request a Quote: TRX CU MC 0044
TRX CU ST 00444440Cummins X2.7TAA-G8Stamford S1L2K150 HzView: TRX CU ST 0044Request a Quote: TRX CU ST 0044
TRX CU TA 00444440Cummins X2.7TAA-G8Terex TA180-34N250 HzView: TRX CU TA 0044Request a Quote: TRX CU TA 0044
TRX IV LS 00444440FPT Iveco R24Leroy-Somer TAL042 F50 HzView: TRX IV LS 0044Request a Quote: TRX IV LS 0044
TRX IV MC 00444440FPT Iveco R24Mecc Alte ECP32-2S/450 HzView: TRX IV MC 0044Request a Quote: TRX IV MC 0044
TRX IV ST 00444440FPT Iveco R24Stamford S1L2-N50 HzView: TRX IV ST 0044Request a Quote: TRX IV ST 0044
TRX IV TA 00444440FPT Iveco R24Terex TA180-34N250 HzView: TRX IV TA 0044Request a Quote: TRX IV TA 0044
TRX KF TA 00444440Kofo MN4100ZDS-42Terex TA180-34N250 HzView: TRX KF TA 0044Request a Quote: TRX KF TA 0044
TRX YD TA 00444440Yangdong Y4105DTerex TA180-34N250 HzView: TRX YD TA 0044Request a Quote: TRX YD TA 0044
TRX QZ TA 00464641.4Quartz Q4100DTerex TA180-34N250 HzView: TRX QZ TA 0046Request a Quote: TRX QZ TA 0046
TRX KB TA 00484845Kubota V3800DI-T-E2BGTerex TA180-34N250 HzView: TRX KB TA 0048Request a Quote: TRX KB TA 0048
TRX BD MC 00505045Baudouin 4M06G50/5Mecc Alte ECP32-2S/450 HzView: TRX BD MC 0050Request a Quote: TRX BD MC 0050
TRX BD ST 00505045Baudouin 4M06G50/5Stamford S1L2-N50 HzView: TRX BD ST 0050Request a Quote: TRX BD ST 0050
TRX BD TA 00505045Baudouin 4M06G50/5Terex TA180-34N250 HzView: TRX BD TA 0050Request a Quote: TRX BD TA 0050
TRX P LS 00505045Perkins 1103A-33TG1Leroy-Somer TAL042 F50 HzView: TRX P LS 0050Request a Quote: TRX P LS 0050
TRX P MC 00505045Perkins 1103A-33TG1Mecc Alte ECP32-2S/450 HzView: TRX P MC 0050Request a Quote: TRX P MC 0050
TRX P ST 00505045Perkins 1103A-33TG1Stamford S1L2-N50 HzView: TRX P ST 0050Request a Quote: TRX P ST 0050
TRX P TA 00505045Perkins 1103A-33TG1Terex TA180-34N250 HzView: TRX P TA 0050Request a Quote: TRX P TA 0050
TRX YD TA 00505045Yangdong Y4110DTerex TA180-34N250 HzView: TRX YD TA 0050Request a Quote: TRX YD TA 0050
TRX QZ TA 00525246.8Quartz Q4100ZDTerex TA180-34N250 HzView: TRX QZ TA 0052Request a Quote: TRX QZ TA 0052
TRX BD MC 00555550Baudouin 4M06G10D0/SMecc Alte ECP32-2M50 HzView: TRX BD MC 0055Request a Quote: TRX BD MC 0055
TRX BD ST 00555550Baudouin 4M06G10D0/SStamford S1L2-Y50 HzView: TRX BD ST 0055Request a Quote: TRX BD ST 0055
TRX BD TA 00555550Baudouin 4M06G10D0/STerex TA180-40N250 HzView: TRX BD TA 0055Request a Quote: TRX BD TA 0055
TRX CU LS 00555550Cummins 4BTAA3.3G11Leroy-Somer TAL042 H50 HzView: TRX CU LS 0055Request a Quote: TRX CU LS 0055
TRX CU MC 00555550Cummins 4BTAA3.3G11Mecc Alte ECP32-2M50 HzView: TRX CU MC 0055Request a Quote: TRX CU MC 0055
TRX CU ST 00555550Cummins 4BTAA3.3G11Stamford S2L1D-D450 HzView: TRX CU ST 0055Request a Quote: TRX CU ST 0055
TRX CU TA 00555550Cummins 4BTAA3.3G11Terex TA180-40N250 HzView: TRX CU TA 0055Request a Quote: TRX CU TA 0055
TRX IV LS 00555550FPT Iveco NEF45AM2Leroy-Somer TAL042 H50 HzView: TRX IV LS 0055Request a Quote: TRX IV LS 0055
TRX IV MC 00555550FPT Iveco NEF45AM2Mecc Alte ECP32-2M50 HzView: TRX IV MC 0055Request a Quote: TRX IV MC 0055
TRX IV ST 00555550FPT Iveco NEF45AM2Stamford S1L2-N50 HzView: TRX IV ST 0055Request a Quote: TRX IV ST 0055
TRX IV TA 00555550FPT Iveco NEF45AM2Terex TA180-40N250 HzView: TRX IV TA 0055Request a Quote: TRX IV TA 0055
TRX KF TA 00555550Kofo MN4100ZDS-46Terex TA180-36N250 HzView: TRX KF TA 0055Request a Quote: TRX KF TA 0055
TRX YD TA 00555550Yangdong Y4102ZLDTerex TA180-36N250 HzView: TRX YD TA 0055Request a Quote: TRX YD TA 0055
TRX QZ TA 00585852.2Quartz Q4105DTerex TA180-36N250 HzView: TRX QZ TA 0058Request a Quote: TRX QZ TA 0058

Not sure how much power you need? Let’s calculate it together

Fuel consumption, tank, dimensions and weight

Values are taken from our product data. Dimension, weight and tank columns are for the Canopied (soundproof) version; fields without data are shown as "–".

ModelAt 50% load (L/h)At 75% load (L/h)At 100% load (L/h)Fuel tank (L)Dimensions (L × W × H) (mm)Weight (kg)
TRX CU LS 0040–––1252200 × 1000 × 15501,095
TRX CU MC 0040–––1252200 × 1000 × 15501,095
TRX CU ST 0040–––1252200 × 1000 × 15501,095
TRX CU TA 0040–––1252200 × 1000 × 15501,095
TRX YD TA 00404.867.61012300 × 1000 × 1545841
TRX BD MC 00444.779.51012300 × 1000 × 1545861
TRX BD ST 00444.779.51012300 × 1000 × 1545870
TRX BD TA 00444.779.51012300 × 1000 × 1545870
TRX CU LS 0044–––1252200 × 1000 × 15501,095
TRX CU MC 0044–––1252200 × 1000 × 15501,095
TRX CU ST 0044–––1252200 × 1000 × 15501,095
TRX CU TA 0044–––1252200 × 1000 × 15501,095
TRX IV LS 00446.2–10.21252200 × 1000 × 1550995
TRX IV MC 00446.2–10.21252200 × 1000 × 1550995
TRX IV ST 00446.2–10.21252200 × 1000 × 1550995
TRX IV TA 00446.2–10.21252200 × 1000 × 1550995
TRX KF TA 00446.29.111.51252350 × 1000 × 1550975
TRX YD TA 00445.66.88.81012300 × 1000 × 1545851
TRX QZ TA 00463.95.87.81252200 × 1000 × 15501,195
TRX KB TA 00485.57.210.31352225 × 950 × 16601,060
TRX BD MC 00505.4810.71012300 × 1000 × 1545836
TRX BD ST 00505.4810.71012300 × 1000 × 1545900
TRX BD TA 00505.4810.71012300 × 1000 × 1545900
TRX P LS 00505.78.210.71012300 × 1000 × 1545985
TRX P MC 00505.78.210.71012300 × 1000 × 1545969
TRX P ST 00505.78.210.71012300 × 1000 × 1545998
TRX P TA 00505.78.210.71012300 × 1000 × 1545998
TRX YD TA 00506.99.2121001800 × 1000 × 12501,330
TRX QZ TA 00526.47.49.91252200 × 1000 × 15501,250
TRX BD MC 005568.911.91012300 × 1000 × 1545844
TRX BD ST 005568.911.91012300 × 1000 × 1545898
TRX BD TA 005568.911.91012300 × 1000 × 1545898
TRX CU LS 0055–9.412.31252200 × 1000 × 15501,095
TRX CU MC 0055–9.412.31252200 × 1000 × 15501,095
TRX CU ST 0055–9.412.31252200 × 1000 × 15501,095
TRX CU TA 0055–9.412.31252200 × 1000 × 15501,095
TRX IV LS 0055–––1252200 × 1000 × 15501,095
TRX IV MC 0055–––1252200 × 1000 × 15501,095
TRX IV ST 0055–––1252200 × 1000 × 15501,095
TRX IV TA 0055–––1252200 × 1000 × 15501,095
TRX KF TA 005569121252350 × 1000 × 15501,035
TRX YD TA 00556.78.510.81012300 × 1000 × 1545934
TRX QZ TA 00585.5810.92202440 × 1000 × 18601,310

What can a 50 kVA generator supply?

At a power factor of 0.8, 50 kVA corresponds to about 40 kW of active power. On a 400 V three-phase supply, the full-load current is about 72 A.

Generators in this power range are typically used for:

  • Shops, restaurants and cafés
  • Shared services of apartment buildings (lift, booster pump, lighting)
  • Workshops and small production units
  • Irrigation pumps

These examples are general information; the same rating does not cover the same load at every site. Sizing must be based on the total power of the connected equipment, motor starting currents and how much runs at the same time.

To calculate the required rating from a list of equipment: Power Calculator

What determines the price of a 50 kVA generator

Two generators of the same rating can differ in price depending on the equipment chosen. The main factors are:

  • Engine brand and model
  • Alternator brand and model
  • Enclosure: soundproof canopy or open type
  • Control panel and automatic transfer switch (ATS)
  • Fuel tank capacity
  • Delivery location and transport

A written price quote is prepared once you send us your power requirement and preferred equipment.

Get price and lead timeCall +90 216 634 34 06

Frequently asked questions

How many kW is a 50 kVA generator?

At a power factor of 0.8, 50 kVA equals 40 kW of active power (kW = kVA × 0.8). The models on this page have standby ratings of 32–46.4 kW.

How much fuel does a 50 kVA generator use per hour?

According to manufacturer data, the models on this page use 5.8–9.4 litres per hour at 75% load. Consumption varies with load, engine and operating conditions; each model’s values are on its product page.

What does the price of a 50 kVA generator depend on?

The price depends on the engine and alternator brand, the enclosure (canopy or open type), the control panel and ATS, the fuel tank capacity and the delivery location. A written price quote is prepared once you send us your power requirement and preferred equipment.

Request a quote for a 50 kVA generator

Tell us your power requirement, duty (standby or prime) and delivery location, and we will prepare a quote for your project.

Get price and lead time

Chat on WhatsApp

Download