2000 kVA (1600 kW) Diesel Generator

This page lists 25 diesel generator models with standby ratings of 1875–2250 kVA (1500–1800 kW). Ratings listed: 1875, 1900, 2000, 2200, and 2250 kVA.

Get price and lead timeView models

Terex Diesel high-output canopied diesel generator

Request a quote

Tell us your power requirement, duty (standby or prime) and delivery location, and we will prepare a quote for your project.

Contact us directly

Call +90 216 634 34 06WhatsApp +90 533 582 26 50

Your request has been received. We will contact you as soon as possible.

Could not send. Please try again or call us. You can also reach us directly: WhatsApp +90 533 582 26 50 · info@terexdiesel.com

Too many submissions in a short time. Please try again in a few minutes.

Phone or email (one is enough)

Terms for sales outside Türkiye

  • Warranty outside Türkiye

    12 months or 1,000 operating hours for all engine brands.

  • Certificates

    ISO 9001 · CE · TSE-HYB

  • Export documents

    A commercial invoice and packing list are prepared; a certificate of origin and any other documents the buyer requires are issued on request.

Export Process and Payment

Key figures

Models
25
Standby power range
1,875–2,250 kVA
Engine brands
Perkins, Baudouin, Cummins
Fuel consumption (75% load)
265.4–337 L/h

Figures are calculated from the technical data of the models on this page; per-model values are on each product page.

Models rated 1875–2250 kVA standby

The table shows each model’s standby and prime ratings, engine and alternator; click a model name for full specifications. Use the compare button in the table to view models side by side.

Models rated 1875–2250 kVA standby
ModelStandby (kVA)Prime (kVA)EngineAlternatorFrequencyCompareView
TRX P LS 18751,8751,710Perkins 4012-46TAG3ALeroy-Somer LSA 52.3 S550 HzView: TRX P LS 1875Request a Quote: TRX P LS 1875
TRX P MC 18751,8751,710Perkins 4012-46TAG3AMecc Alte ECO46-2S/450 HzView: TRX P MC 1875Request a Quote: TRX P MC 1875
TRX P ST 18751,8751,710Perkins 4012-46TAG3AStamford S7L1D-E50 HzView: TRX P ST 1875Request a Quote: TRX P ST 1875
TRX P TA 18751,8751,710Perkins 4012-46TAG3ATerex TA450-1500N50 HzView: TRX P TA 1875Request a Quote: TRX P TA 1875
TRX BD MC 19001,9001,750Baudouin 16M33G1900/5Mecc Alte ECO46-2S/450 HzView: TRX BD MC 1900Request a Quote: TRX BD MC 1900
TRX BD ST 19001,9001,750Baudouin 16M33G1900/5Stamford S7L1D-E50 HzView: TRX BD ST 1900Request a Quote: TRX BD ST 1900
TRX BD TA 19001,9001,750Baudouin 16M33G1900/5Terex TA450-1500N50 HzView: TRX BD TA 1900Request a Quote: TRX BD TA 1900
TRX BD MC 20002,0001,830Baudouin 16M33G2000/5Mecc Alte ECO46-2S/450 HzView: TRX BD MC 2000Request a Quote: TRX BD MC 2000
TRX BD ST 20002,0001,830Baudouin 16M33G2000/5Stamford S7L1D-F50 HzView: TRX BD ST 2000Request a Quote: TRX BD ST 2000
TRX BD TA 20002,0001,830Baudouin 16M33G2000/5Terex TA450-1500N50 HzView: TRX BD TA 2000Request a Quote: TRX BD TA 2000
TRX P LS 20002,0001,850Perkins 4016-61TRG1Leroy-Somer LSA 52.3 S550 HzView: TRX P LS 2000Request a Quote: TRX P LS 2000
TRX P MC 20002,0001,850Perkins 4016-61TRG1Mecc Alte ECO46-2S/450 HzView: TRX P MC 2000Request a Quote: TRX P MC 2000
TRX P ST 20002,0001,850Perkins 4016-61TRG1Stamford S7L1D-F50 HzView: TRX P ST 2000Request a Quote: TRX P ST 2000
TRX P TA 20002,0001,850Perkins 4016-61TRG1Terex TA450-1500N50 HzView: TRX P TA 2000Request a Quote: TRX P TA 2000
TRX CU LS 22002,2002,000Cummins QSK60G4Leroy-Somer LSA 52.3 S750 HzView: TRX CU LS 2200Request a Quote: TRX CU LS 2200
TRX CU MC 22002,2002,000Cummins QSK60G4Mecc Alte ECO46-1L/450 HzView: TRX CU MC 2200Request a Quote: TRX CU MC 2200
TRX CU ST 22002,2002,000Cummins QSK60G4Stamford S7L1D-G50 HzView: TRX CU ST 2200Request a Quote: TRX CU ST 2200
TRX CU TA 22002,2002,000Cummins QSK60G4Terex TA450-1600N50 HzView: TRX CU TA 2200Request a Quote: TRX CU TA 2200
TRX BD MC 22502,2502,050Baudouin 16M33G2250/5Mecc Alte ECO46-1L/450 HzView: TRX BD MC 2250Request a Quote: TRX BD MC 2250
TRX BD ST 22502,2502,050Baudouin 16M33G2250/5Stamford S7L1D-G50 HzView: TRX BD ST 2250Request a Quote: TRX BD ST 2250
TRX BD TA 22502,2502,050Baudouin 16M33G2250/5Terex TA450-1600N50 HzView: TRX BD TA 2250Request a Quote: TRX BD TA 2250
TRX P LS 22502,2502,000Perkins 4016-61TRG2Leroy-Somer LSA 52.3 S750 HzView: TRX P LS 2250Request a Quote: TRX P LS 2250
TRX P MC 22502,2502,000Perkins 4016-61TRG2Mecc Alte ECO46-1L/450 HzView: TRX P MC 2250Request a Quote: TRX P MC 2250
TRX P ST 22502,2502,000Perkins 4016-61TRG2Stamford S7L1D-G50 HzView: TRX P ST 2250Request a Quote: TRX P ST 2250
TRX P TA 22502,2502,000Perkins 4016-61TRG2Terex TA450-1600N50 HzView: TRX P TA 2250Request a Quote: TRX P TA 2250

Not sure how much power you need? Let’s calculate it together

Fuel consumption, tank, dimensions and weight

Values are taken from our product data. Dimension, weight and tank columns are for the Open type version; fields without data are shown as "–".

ModelAt 50% load (L/h)At 75% load (L/h)At 100% load (L/h)Fuel tank (L)Dimensions (L × W × H) (mm)Weight (kg)
TRX P LS 18751872753703,0004950 × 2200 × 272011,858
TRX P MC 18751872753703,0004950 × 2200 × 272011,858
TRX P ST 18751872753703,0004950 × 2200 × 272011,935
TRX P TA 18751872753703,0004950 × 2200 × 272011,935
TRX BD MC 1900179.7265.4364.33,0005225 × 2206 × 278212,000
TRX BD ST 1900179.7265.4364.33,0005225 × 2206 × 278212,000
TRX BD TA 1900179.7265.4364.33,0005225 × 2206 × 278212,000
TRX BD MC 2000194.7290.74013,0005225 × 2206 × 278213,949
TRX BD ST 2000194.7290.74013,0005225 × 2206 × 278213,700
TRX BD TA 2000194.7290.74013,0005225 × 2206 × 278213,700
TRX P LS 20002123374472,3505150 × 2500 × 320012,000
TRX P MC 20002123374472,3505150 × 2500 × 320012,000
TRX P ST 20002123374472,3505150 × 2500 × 320012,000
TRX P TA 20002123374472,3505150 × 2500 × 320012,000
TRX CU LS 22002002913942,3505150 × 2500 × 320012,000
TRX CU MC 22002002913942,3505150 × 2500 × 320012,000
TRX CU ST 22002002913942,3505150 × 2500 × 320012,000
TRX CU TA 22002002913942,3505150 × 2500 × 320012,000
TRX BD MC 2250208.8311.3428.63,0005950 × 2245 × 288514,576
TRX BD ST 2250208.8311.3428.63,0005950 × 2245 × 288514,576
TRX BD TA 2250208.8311.3428.63,0005950 × 2245 × 288514,576
TRX P LS 22502093174422,3505150 × 2500 × 320012,850
TRX P MC 22502093174422,3505150 × 2500 × 320012,850
TRX P ST 22502093174422,3505150 × 2500 × 320012,850
TRX P TA 22502093174422,3505150 × 2500 × 320012,850

What can a 2000 kVA generator supply?

At a power factor of 0.8, 2000 kVA corresponds to about 1,600 kW of active power. On a 400 V three-phase supply, the full-load current is about 2,887 A.

Generators in this power range are typically used for:

  • Large industrial plants
  • Hospital campuses and data centres
  • Mining and energy sites
  • Multi-generator systems running in parallel

These examples are general information; the same rating does not cover the same load at every site. Sizing must be based on the total power of the connected equipment, motor starting currents and how much runs at the same time.

To calculate the required rating from a list of equipment: Power Calculator

What determines the price of a 2000 kVA generator

Two generators of the same rating can differ in price depending on the equipment chosen. The main factors are:

  • Engine brand and model
  • Alternator brand and model
  • Enclosure: container or open type
  • Control panel and automatic transfer switch (ATS)
  • Fuel tank capacity
  • Delivery location and transport

A written price quote is prepared once you send us your power requirement and preferred equipment.

Get price and lead timeCall +90 216 634 34 06

One set or several sets in parallel?

In this power class the load can be supplied by one set or by several sets running in parallel through a synchronization panel. In a parallel system one set can be stopped for maintenance while the others carry the load, and at low load one set can be shut down. The choice depends on the load profile, the redundancy required and site conditions, and is made at the quotation stage.

Standby power is for backup during mains failures. Where there is no grid, or the set will run for long periods, size the set on its prime rating.

Canopy sets go up to 1,100 kVA; sets above 1,100 kVA are supplied in a container: Containerised Generators

Frequently asked questions

How many kW is a 2000 kVA generator?

At a power factor of 0.8, 2000 kVA equals 1600 kW of active power (kW = kVA × 0.8). The models on this page have standby ratings of 1500–1800 kW.

How much fuel does a 2000 kVA generator use per hour?

According to manufacturer data, the models on this page use 265.4–337 litres per hour at 75% load. Consumption varies with load, engine and operating conditions; each model’s values are on its product page.

What does the price of a 2000 kVA generator depend on?

The price depends on the engine and alternator brand, the enclosure (container or open type), the control panel and ATS, the fuel tank capacity and the delivery location. A written price quote is prepared once you send us your power requirement and preferred equipment.

Request a quote for a 2000 kVA generator

Tell us your power requirement, duty (standby or prime) and delivery location, and we will prepare a quote for your project.

Get price and lead time

Chat on WhatsApp

Download