400 kVA (320 kW) Diesel Generator
This page lists 63 diesel generator models with standby ratings of 305–415 kVA (244–332 kW). Ratings listed: 305, 330, 344, 350, 360, 385, 400, 412, and 415 kVA.

Request a quote
Tell us your power requirement, duty (standby or prime) and delivery location, and we will prepare a quote for your project.
Contact us directly
Terms for sales outside Türkiye
- Warranty outside Türkiye
12 months or 1,000 operating hours for all engine brands.
- Certificates
ISO 9001 · CE · TSE-HYB
- Export documents
A commercial invoice and packing list are prepared; a certificate of origin and any other documents the buyer requires are issued on request.
Key figures
- Models
- 63
- Standby power range
- 305–415 kVA
- Engine brands
- Perkins, Baudouin, Cummins, FPT Iveco, Kofo, Quartz, Scania, SDEC, Volvo Penta, Yuchai
- Fuel consumption (75% load)
- 40–60.7 L/h
- Weight with canopy
- 2,220–4,925 kg
- Typical canopy dimensions (L × W × H)
- 3750 × 1500 × 2500 mm
Figures are calculated from the technical data of the models on this page; per-model values are on each product page.
Models rated 305–415 kVA standby
The table shows each model’s standby and prime ratings, engine and alternator; click a model name for full specifications. Use the compare button in the table to view models side by side.
Not sure how much power you need? Let’s calculate it together
Fuel consumption, tank, dimensions and weight
Values are taken from our product data. Dimension, weight and tank columns are for the Canopied (soundproof) version; fields without data are shown as "–".
| Model | At 50% load (L/h) | At 75% load (L/h) | At 100% load (L/h) | Fuel tank (L) | Dimensions (L × W × H) (mm) | Weight (kg) |
|---|---|---|---|---|---|---|
| TRX QZ TA 0305 | 27 | 40 | 53.8 | 350 | – | 3,150 |
| TRX CU LS 0330 | 31 | 46 | 63 | 350 | – | 3,500 |
| TRX CU MC 0330 | 31 | 46 | 63 | 350 | – | 3,500 |
| TRX CU ST 0330 | 31 | 46 | 63 | 350 | – | 2,880 |
| TRX CU TA 0330 | 31 | 46 | 63 | 350 | – | 3,500 |
| TRX IV LS 0330 | 37.3 | 52.6 | 66.6 | 846 | 3750 × 1400 × 2646 | 3,471 |
| TRX IV MC 0330 | 37.3 | 52.6 | 66.6 | 846 | 3750 × 1400 × 2646 | 3,054 |
| TRX IV ST 0330 | 37.3 | 52.6 | 66.6 | 846 | 3750 × 1400 × 2646 | 3,471 |
| TRX IV TA 0330 | 37.3 | 52.6 | 66.6 | 846 | 3750 × 1400 × 2646 | 3,471 |
| TRX KF TA 0330 | 27 | 40 | 56 | 350 | 3400 × 1200 × 2100 | 2,220 |
| TRX P LS 0330 | 33 | 48.2 | 64.9 | 415 | 3600 × 1200 × 2288 | 2,966 |
| TRX P MC 0330 | 33 | 48.2 | 64.9 | 415 | 3600 × 1200 × 2288 | 2,985 |
| TRX P ST 0330 | 33 | 48.2 | 64.9 | 415 | 3600 × 1200 × 2288 | 3,152 |
| TRX P TA 0330 | 33 | 48.2 | 64.9 | 415 | 3600 × 1200 × 2288 | 3,152 |
| TRX QZ TA 0330 | 27 | 40 | 53.8 | 350 | – | 3,500 |
| TRX SD TA 0330 | 32.1 | 49.4 | 60.8 | 846 | 3750 × 1400 × 2646 | 3,364 |
| TRX VL MC 0330 | – | – | – | 415 | 3600 × 1200 × 2288 | 3,300 |
| TRX VL ST 0330 | – | – | – | 415 | 3600 × 1200 × 2288 | 3,300 |
| TRX VL TA 0330 | – | – | – | 415 | 3600 × 1200 × 2288 | 3,300 |
| TRX SD TA 0344 | 33.1 | 50.4 | 67.5 | 350 | – | 3,800 |
| TRX BD MC 0350 | 35.4 | 52.3 | 70.5 | 547 | 3987 × 1320 × 2025 | 3,068 |
| TRX BD ST 0350 | 35.4 | 52.3 | 70.5 | 547 | 3987 × 1320 × 2025 | 3,209 |
| TRX BD TA 0350 | 35.4 | 52.3 | 70.5 | 547 | 3987 × 1320 × 2025 | 3,209 |
| TRX CU LS 0350 | 35 | 52 | 70 | 350 | – | 3,700 |
| TRX CU MC 0350 | 35 | 52 | 70 | 350 | – | 3,700 |
| TRX CU ST 0350 | 35 | 52 | 70 | 350 | – | 3,045 |
| TRX CU TA 0350 | 35 | 52 | 70 | 350 | – | 3,700 |
| TRX VL MC 0350 | – | – | – | 415 | 3600 × 1200 × 2288 | 3,500 |
| TRX VL ST 0350 | – | – | – | 415 | 3600 × 1200 × 2288 | 3,500 |
| TRX VL TA 0350 | – | – | – | 415 | 3600 × 1200 × 2288 | 3,500 |
| TRX YC TA 0350 | 35.6 | 51.8 | 69.1 | 590 | 3950 × 1250 × 2450 | 3,300 |
| TRX SC MC 0360 | 32.8 | 48.7 | 67.7 | 350 | – | 3,500 |
| TRX SC ST 0360 | 32.8 | 48.7 | 67.7 | 350 | – | 3,500 |
| TRX SC TA 0360 | 32.8 | 48.7 | 67.7 | 350 | – | 3,500 |
| TRX IV LS 0385 | 38.8 | 57.3 | 70 | 846 | 3750 × 1400 × 2646 | 3,474 |
| TRX IV MC 0385 | 38.8 | 57.3 | 70 | 846 | 3750 × 1400 × 2646 | 3,334 |
| TRX IV ST 0385 | 38.8 | 57.3 | 70 | 846 | 3750 × 1400 × 2646 | 3,474 |
| TRX IV TA 0385 | 38.8 | 57.3 | 70 | 846 | 3750 × 1400 × 2646 | 3,474 |
| TRX KF TA 0385 | 29 | 45 | 63 | 810 | 3750 × 1500 × 2500 | 2,650 |
| TRX VL MC 0385 | 35.9 | 52.2 | 69.3 | 979 | 4089 × 1420 × 2566 | 3,764 |
| TRX VL ST 0385 | 35.9 | 52.2 | 69.3 | 979 | 4089 × 1420 × 2566 | 3,739 |
| TRX VL TA 0385 | 35.9 | 52.2 | 69.3 | 979 | 4089 × 1420 × 2566 | 3,739 |
| TRX BD MC 0400 | 41 | 60.7 | 82.1 | 846 | 3750 × 1400 × 2646 | 3,260 |
| TRX BD ST 0400 | 41 | 60.7 | 82.1 | 846 | 3750 × 1400 × 2646 | 3,240 |
| TRX BD TA 0400 | 41 | 60.7 | 82.1 | 846 | 3750 × 1400 × 2646 | 3,240 |
| TRX CU LS 0400 | – | – | – | 1,370 | – | 4,925 |
| TRX CU MC 0400 | – | – | – | 1,370 | – | 4,925 |
| TRX CU ST 0400 | – | – | – | 1,370 | – | 4,925 |
| TRX CU TA 0400 | – | – | – | 1,370 | – | 4,925 |
| TRX P LS 0400 | 37 | 54 | 71 | 819 | 4050 × 1600 × 2615 | 3,846 |
| TRX P MC 0400 | 37 | 54 | 71 | 819 | 4050 × 1600 × 2615 | 3,846 |
| TRX P ST 0400 | 37 | 54 | 71 | 819 | 4050 × 1600 × 2615 | 3,986 |
| TRX P TA 0400 | 37 | 54 | 71 | 819 | 4050 × 1600 × 2615 | 3,986 |
| TRX QZ TA 0400 | 29 | 42 | 55.8 | 350 | – | 4,000 |
| TRX SC MC 0400 | 36 | 53.2 | 70.6 | 1,370 | – | 4,925 |
| TRX SC ST 0400 | 36 | 53.2 | 70.6 | 1,370 | – | 4,925 |
| TRX SC TA 0400 | 36 | 53.2 | 70.6 | 1,370 | – | 4,925 |
| TRX SD TA 0400 | 41.1 | 59.8 | 81.2 | 846 | 3750 × 1400 × 2646 | 3,593 |
| TRX VL ST 0400 | – | – | – | 810 | 4640 × 1600 × 2750 | 4,500 |
| TRX YC TA 0412 | 41.1 | 60 | 80.7 | 810 | 4640 × 1600 × 2750 | 4,200 |
| TRX VL MC 0415 | 38.3 | 56 | 74.3 | 979 | 4089 × 1420 × 2566 | 3,764 |
| TRX VL ST 0415 | 38.3 | 56 | 74.3 | 979 | 4089 × 1420 × 2566 | 3,739 |
| TRX VL TA 0415 | 38.3 | 56 | 74.3 | 979 | 4089 × 1420 × 2566 | 3,739 |
What can a 400 kVA generator supply?
At a power factor of 0.8, 400 kVA corresponds to about 320 kW of active power. On a 400 V three-phase supply, the full-load current is about 577 A.
Generators in this power range are typically used for:
- Factories and production plants
- Hospitals, shopping centres and large commercial buildings
- Server rooms and telecom centres
- Large construction sites and infrastructure projects
These examples are general information; the same rating does not cover the same load at every site. Sizing must be based on the total power of the connected equipment, motor starting currents and how much runs at the same time.
To calculate the required rating from a list of equipment: Power Calculator
What determines the price of a 400 kVA generator
Two generators of the same rating can differ in price depending on the equipment chosen. The main factors are:
- Engine brand and model
- Alternator brand and model
- Enclosure: soundproof canopy or open type
- Control panel and automatic transfer switch (ATS)
- Fuel tank capacity
- Delivery location and transport
A written price quote is prepared once you send us your power requirement and preferred equipment.
Frequently asked questions
How many kW is a 400 kVA generator?
At a power factor of 0.8, 400 kVA equals 320 kW of active power (kW = kVA × 0.8). The models on this page have standby ratings of 244–332 kW.
How much fuel does a 400 kVA generator use per hour?
According to manufacturer data, the models on this page use 40–60.7 litres per hour at 75% load. Consumption varies with load, engine and operating conditions; each model’s values are on its product page.
What does the price of a 400 kVA generator depend on?
The price depends on the engine and alternator brand, the enclosure (canopy or open type), the control panel and ATS, the fuel tank capacity and the delivery location. A written price quote is prepared once you send us your power requirement and preferred equipment.
Request a quote for a 400 kVA generator
Tell us your power requirement, duty (standby or prime) and delivery location, and we will prepare a quote for your project.