400 kVA (320 kW) dizel generator

Ushbu sahifada standby quvvati 305–415 kVA (244–332 kW) bo‘lgan 63 ta dizel generator modeli keltirilgan. Ro‘yxatdagi quvvatlar: 305, 330, 344, 350, 360, 385, 400, 412 va 415 kVA.

Narx va yetkazib berish muddatini bilishModellarni ko‘rish

Terex Diesel shovqin izolyatsiyali kabinali dizel generator

Taklif va ma’lumot so‘rovi

Quvvat ehtiyojingiz, foydalanish rejimi (standby yoki prime) va yetkazib berish joyini yuboring; taklifni loyihangizga mos tayyorlaymiz.

Biz bilan bevosita bog‘laning

Qo‘ng‘iroq +90 216 634 34 06WhatsApp +90 533 582 26 50

So‘rovingiz qabul qilindi. Tez orada Siz bilan bog‘lanamiz.

Yuborib bo‘lmadi. Iltimos, qayta urinib ko‘ring yoki bizga qo‘ng‘iroq qiling. Biz bilan bevosita ham bog‘lanishingiz mumkin: WhatsApp +90 533 582 26 50 · info@terexdiesel.com

Qisqa vaqt ichida juda ko‘p so‘rov yuborildi. Iltimos, bir necha daqiqadan so‘ng qayta urinib ko‘ring.

Telefon yoki elektron pochta (bittasi yetarli)

Turkiyadan tashqaridagi savdolar uchun shartlar

  • Turkiyadan tashqarida kafolat

    Barcha dvigatel markalarida 12 oy yoki 1 000 ish soati.

  • Sertifikatlar

    ISO 9001 · CE · TSE-HYB

  • Eksport hujjatlari

    Tijorat hisob-fakturasi va qadoqlash varaqasi tayyorlanadi; kelib chiqish sertifikati va xaridor talab qilgan boshqa hujjatlar so‘rov bo‘yicha rasmiylashtiriladi.

Eksport jarayoni va to‘lov

Asosiy ko‘rsatkichlar

Modellar soni
63
Standby quvvat diapazoni
305–415 kVA
Dvigatel markalari
Perkins, Baudouin, Cummins, FPT Iveco, Kofo, Quartz, Scania, SDEC, Volvo Penta, Yuchai
Yoqilg‘i sarfi (75% yuklama)
40–60,7 L/soat
Kabinali og‘irlik
2 220–4 925 kg
Odatiy kabinali o‘lchamlar (U × E × B)
3750 × 1500 × 2500 mm

Qiymatlar ushbu sahifadagi modellarning texnik ma’lumotlaridan hisoblangan; har bir modelning qiymatlari mahsulot sahifasida.

Standby quvvati 305–415 kVA bo‘lgan modellar

Jadvalda har bir modelning standby va prime quvvati, dvigateli va alternatori ko‘rsatilgan; texnik ma’lumotlar uchun model nomini bosing. Modellarni yonma-yon ko‘rish uchun jadvaldagi solishtirish tugmasidan foydalaning.

Standby quvvati 305–415 kVA bo‘lgan modellar
ModelStandby (kVA)Prime (kVA)DvigatelAlternatorChastotaSolishtirishBatafsil
TRX QZ TA 0305305274,5Quartz Q6D10D258ATerex TA280-240N50 HzBatafsil: TRX QZ TA 0305Taklif so‘rash: TRX QZ TA 0305
TRX CU LS 0330330300Cummins QSL9-G15Leroy-Somer TAL046 F50 HzBatafsil: TRX CU LS 0330Taklif so‘rash: TRX CU LS 0330
TRX CU MC 0330330300Cummins QSL9-G15Mecc Alte ECO38-1L/450 HzBatafsil: TRX CU MC 0330Taklif so‘rash: TRX CU MC 0330
TRX CU ST 0330330300Cummins QSL9-G15Stamford HCI444D50 HzBatafsil: TRX CU ST 0330Taklif so‘rash: TRX CU ST 0330
TRX CU TA 0330330300Cummins QSL9-G15Terex TA280-240N50 HzBatafsil: TRX CU TA 0330Taklif so‘rash: TRX CU TA 0330
TRX IV LS 0330330300FPT Iveco C87TE4Leroy-Somer TAL046 F50 HzBatafsil: TRX IV LS 0330Taklif so‘rash: TRX IV LS 0330
TRX IV MC 0330330300FPT Iveco C87TE4Mecc Alte ECO38-1L/450 HzBatafsil: TRX IV MC 0330Taklif so‘rash: TRX IV MC 0330
TRX IV ST 0330330300FPT Iveco C87TE4Stamford S4L1D-D50 HzBatafsil: TRX IV ST 0330Taklif so‘rash: TRX IV ST 0330
TRX IV TA 0330330300FPT Iveco C87TE4Terex TA280-240N50 HzBatafsil: TRX IV TA 0330Taklif so‘rash: TRX IV TA 0330
TRX KF TA 0330330300Kofo WT10B-275DTerex TA280-260N50 HzBatafsil: TRX KF TA 0330Taklif so‘rash: TRX KF TA 0330
TRX P LS 0330330300Perkins 1506A-E88TAG5Leroy-Somer TAL046 F50 HzBatafsil: TRX P LS 0330Taklif so‘rash: TRX P LS 0330
TRX P MC 0330330300Perkins 1506A-E88TAG5Mecc Alte ECO38-1L/450 HzBatafsil: TRX P MC 0330Taklif so‘rash: TRX P MC 0330
TRX P ST 0330330300Perkins 1506A-E88TAG5Stamford S4L1D-D50 HzBatafsil: TRX P ST 0330Taklif so‘rash: TRX P ST 0330
TRX P TA 0330330300Perkins 1506A-E88TAG5Terex TA280-240N50 HzBatafsil: TRX P TA 0330Taklif so‘rash: TRX P TA 0330
TRX QZ TA 0330330297Quartz Q6D10D258ATerex TA280-260N50 HzBatafsil: TRX QZ TA 0330Taklif so‘rash: TRX QZ TA 0330
TRX SD TA 0330330300SDEC SC10E380D2Terex TA280-240N50 HzBatafsil: TRX SD TA 0330Taklif so‘rash: TRX SD TA 0330
TRX VL MC 0330330300Volvo Penta TAD842GEMecc Alte ECO38-1L/450 HzBatafsil: TRX VL MC 0330Taklif so‘rash: TRX VL MC 0330
TRX VL ST 0330330300Volvo Penta TAD842GEStamford S4L1D-D50 HzBatafsil: TRX VL ST 0330Taklif so‘rash: TRX VL ST 0330
TRX VL TA 0330330300Volvo Penta TAD842GETerex TA280-240N50 HzBatafsil: TRX VL TA 0330Taklif so‘rash: TRX VL TA 0330
TRX SD TA 0344344313SDEC SC10E400D2Terex TA315-300N50 HzBatafsil: TRX SD TA 0344Taklif so‘rash: TRX SD TA 0344
TRX BD MC 0350350320Baudouin 6M16G350/5Mecc Alte ECO40-1S/450 HzBatafsil: TRX BD MC 0350Taklif so‘rash: TRX BD MC 0350
TRX BD ST 0350350320Baudouin 6M16G350/5Stamford S4L1D-E50 HzBatafsil: TRX BD ST 0350Taklif so‘rash: TRX BD ST 0350
TRX BD TA 0350350320Baudouin 6M16G350/5Terex TA315-300N50 HzBatafsil: TRX BD TA 0350Taklif so‘rash: TRX BD TA 0350
TRX CU LS 0350350320Cummins QSL9-G15Leroy-Somer TAL046 H50 HzBatafsil: TRX CU LS 0350Taklif so‘rash: TRX CU LS 0350
TRX CU MC 0350350320Cummins QSL9-G15Mecc Alte ECO40-1S/450 HzBatafsil: TRX CU MC 0350Taklif so‘rash: TRX CU MC 0350
TRX CU ST 0350350320Cummins QSL9-G15Stamford S4L1D-E50 HzBatafsil: TRX CU ST 0350Taklif so‘rash: TRX CU ST 0350
TRX CU TA 0350350320Cummins QSL9-G15Terex TA315-300N50 HzBatafsil: TRX CU TA 0350Taklif so‘rash: TRX CU TA 0350
TRX VL MC 0350350326Volvo Penta TAD843GEMecc Alte ECO40-1S/450 HzBatafsil: TRX VL MC 0350Taklif so‘rash: TRX VL MC 0350
TRX VL ST 0350350326Volvo Penta TAD843GEStamford S4L1D-E50 HzBatafsil: TRX VL ST 0350Taklif so‘rash: TRX VL ST 0350
TRX VL TA 0350350326Volvo Penta TAD843GETerex TA315-300N50 HzBatafsil: TRX VL TA 0350Taklif so‘rash: TRX VL TA 0350
TRX YC TA 0350350312,5Yuchai YC6MK420L-D20Terex TA315-300N50 HzBatafsil: TRX YC TA 0350Taklif so‘rash: TRX YC TA 0350
TRX SC MC 0360360329Scania DC09072A 02-14Mecc Alte ECO40-1S/450 HzBatafsil: TRX SC MC 0360Taklif so‘rash: TRX SC MC 0360
TRX SC ST 0360360329Scania DC09072A 02-14Stamford S4L1D-E50 HzBatafsil: TRX SC ST 0360Taklif so‘rash: TRX SC ST 0360
TRX SC TA 0360360329Scania DC09072A 02-14Terex TA315-300N50 HzBatafsil: TRX SC TA 0360Taklif so‘rash: TRX SC TA 0360
TRX IV LS 0385385350FPT Iveco C13TE2ALeroy-Somer TAL046 H50 HzBatafsil: TRX IV LS 0385Taklif so‘rash: TRX IV LS 0385
TRX IV MC 0385385350FPT Iveco C13TE2AMecc Alte ECO40-1S/450 HzBatafsil: TRX IV MC 0385Taklif so‘rash: TRX IV MC 0385
TRX IV ST 0385385350FPT Iveco C13TE2AStamford S4L1D-E50 HzBatafsil: TRX IV ST 0385Taklif so‘rash: TRX IV ST 0385
TRX IV TA 0385385350FPT Iveco C13TE2ATerex TA315-300N50 HzBatafsil: TRX IV TA 0385Taklif so‘rash: TRX IV TA 0385
TRX KF TA 0385385350Kofo WT13B-308DTerex TA315-300N50 HzBatafsil: TRX KF TA 0385Taklif so‘rash: TRX KF TA 0385
TRX VL MC 0385385350Volvo Penta TAD1342GEMecc Alte ECO40-1S/450 HzBatafsil: TRX VL MC 0385Taklif so‘rash: TRX VL MC 0385
TRX VL ST 0385385350Volvo Penta TAD1342GEStamford S4L1D-E50 HzBatafsil: TRX VL ST 0385Taklif so‘rash: TRX VL ST 0385
TRX VL TA 0385385350Volvo Penta TAD1342GETerex TA315-300N50 HzBatafsil: TRX VL TA 0385Taklif so‘rash: TRX VL TA 0385
TRX BD MC 0400400360Baudouin 6M21G400/5Mecc Alte ECO40-1S/450 HzBatafsil: TRX BD MC 0400Taklif so‘rash: TRX BD MC 0400
TRX BD ST 0400400360Baudouin 6M21G400/5Stamford S4L1D-E50 HzBatafsil: TRX BD ST 0400Taklif so‘rash: TRX BD ST 0400
TRX BD TA 0400400360Baudouin 6M21G400/5Terex TA315-300N50 HzBatafsil: TRX BD TA 0400Taklif so‘rash: TRX BD TA 0400
TRX CU LS 0400400380Cummins QSN14-G2Leroy-Somer TAL046 H50 HzBatafsil: TRX CU LS 0400Taklif so‘rash: TRX CU LS 0400
TRX CU MC 0400400380Cummins QSN14-G2Mecc Alte ECO40-1S/450 HzBatafsil: TRX CU MC 0400Taklif so‘rash: TRX CU MC 0400
TRX CU ST 0400400380Cummins QSN14-G2Stamford HCI444F50 HzBatafsil: TRX CU ST 0400Taklif so‘rash: TRX CU ST 0400
TRX CU TA 0400400380Cummins QSN14-G2Terex TA315-300N50 HzBatafsil: TRX CU TA 0400Taklif so‘rash: TRX CU TA 0400
TRX P LS 0400400350Perkins 2206A-E13TAG2Leroy-Somer TAL046 H50 HzBatafsil: TRX P LS 0400Taklif so‘rash: TRX P LS 0400
TRX P MC 0400400350Perkins 2206A-E13TAG2Mecc Alte ECO40-1S/450 HzBatafsil: TRX P MC 0400Taklif so‘rash: TRX P MC 0400
TRX P ST 0400400350Perkins 2206A-E13TAG2Stamford S4L1D-E50 HzBatafsil: TRX P ST 0400Taklif so‘rash: TRX P ST 0400
TRX P TA 0400400350Perkins 2206A-E13TAG2Terex TA315-300N50 HzBatafsil: TRX P TA 0400Taklif so‘rash: TRX P TA 0400
TRX QZ TA 0400400360Quartz Q6D12D320ATerex TA315-300N50 HzBatafsil: TRX QZ TA 0400Taklif so‘rash: TRX QZ TA 0400
TRX SC MC 0400400365Scania DC13072A 02-11Mecc Alte ECO40-1S/450 HzBatafsil: TRX SC MC 0400Taklif so‘rash: TRX SC MC 0400
TRX SC ST 0400400365Scania DC13072A 02-11Stamford S4L1D-E50 HzBatafsil: TRX SC ST 0400Taklif so‘rash: TRX SC ST 0400
TRX SC TA 0400400365Scania DC13072A 02-11Terex TA315-300N50 HzBatafsil: TRX SC TA 0400Taklif so‘rash: TRX SC TA 0400
TRX SD TA 0400400365SDEC SC15G500D2Terex TA315-300N50 HzBatafsil: TRX SD TA 0400Taklif so‘rash: TRX SD TA 0400
TRX VL ST 0400400365Volvo Penta TAD1352GEStamford S4L1D-F50 HzBatafsil: TRX VL ST 0400Taklif so‘rash: TRX VL ST 0400
TRX YC TA 0412412375Yuchai YC6MJ500L-D20Terex TA315-320N50 HzBatafsil: TRX YC TA 0412Taklif so‘rash: TRX YC TA 0412
TRX VL MC 0415415375Volvo Penta TAD1343GEMecc Alte ECO40-1S/450 HzBatafsil: TRX VL MC 0415Taklif so‘rash: TRX VL MC 0415
TRX VL ST 0415415375Volvo Penta TAD1343GEStamford S4L1D-E50 HzBatafsil: TRX VL ST 0415Taklif so‘rash: TRX VL ST 0415
TRX VL TA 0415415375Volvo Penta TAD1343GETerex TA315-320N50 HzBatafsil: TRX VL TA 0415Taklif so‘rash: TRX VL TA 0415

Kerakli quvvatni bilmaysizmi? Birgalikda hisoblaymiz

Yoqilg‘i sarfi, bak, o‘lchamlar va og‘irlik

Qiymatlar mahsulot ma’lumotlarimizdan olingan. O‘lcham, og‘irlik va bak ustunlari Kabinali (shovqin izolyatsiyali) korpus uchun; ma’lumot yo‘q maydonlar "–" bilan ko‘rsatiladi.

Model50% yuklamada (L/soat)75% yuklamada (L/soat)100% yuklamada (L/soat)Yoqilg‘i baki (L)O‘lchamlar (U × E × B) (mm)Og‘irlik (kg)
TRX QZ TA 0305274053,8350–3 150
TRX CU LS 0330314663350–3 500
TRX CU MC 0330314663350–3 500
TRX CU ST 0330314663350–2 880
TRX CU TA 0330314663350–3 500
TRX IV LS 033037,352,666,68463750 × 1400 × 26463 471
TRX IV MC 033037,352,666,68463750 × 1400 × 26463 054
TRX IV ST 033037,352,666,68463750 × 1400 × 26463 471
TRX IV TA 033037,352,666,68463750 × 1400 × 26463 471
TRX KF TA 03302740563503400 × 1200 × 21002 220
TRX P LS 03303348,264,94153600 × 1200 × 22882 966
TRX P MC 03303348,264,94153600 × 1200 × 22882 985
TRX P ST 03303348,264,94153600 × 1200 × 22883 152
TRX P TA 03303348,264,94153600 × 1200 × 22883 152
TRX QZ TA 0330274053,8350–3 500
TRX SD TA 033032,149,460,88463750 × 1400 × 26463 364
TRX VL MC 0330–––4153600 × 1200 × 22883 300
TRX VL ST 0330–––4153600 × 1200 × 22883 300
TRX VL TA 0330–––4153600 × 1200 × 22883 300
TRX SD TA 034433,150,467,5350–3 800
TRX BD MC 035035,452,370,55473987 × 1320 × 20253 068
TRX BD ST 035035,452,370,55473987 × 1320 × 20253 209
TRX BD TA 035035,452,370,55473987 × 1320 × 20253 209
TRX CU LS 0350355270350–3 700
TRX CU MC 0350355270350–3 700
TRX CU ST 0350355270350–3 045
TRX CU TA 0350355270350–3 700
TRX VL MC 0350–––4153600 × 1200 × 22883 500
TRX VL ST 0350–––4153600 × 1200 × 22883 500
TRX VL TA 0350–––4153600 × 1200 × 22883 500
TRX YC TA 035035,651,869,15903950 × 1250 × 24503 300
TRX SC MC 036032,848,767,7350–3 500
TRX SC ST 036032,848,767,7350–3 500
TRX SC TA 036032,848,767,7350–3 500
TRX IV LS 038538,857,3708463750 × 1400 × 26463 474
TRX IV MC 038538,857,3708463750 × 1400 × 26463 334
TRX IV ST 038538,857,3708463750 × 1400 × 26463 474
TRX IV TA 038538,857,3708463750 × 1400 × 26463 474
TRX KF TA 03852945638103750 × 1500 × 25002 650
TRX VL MC 038535,952,269,39794089 × 1420 × 25663 764
TRX VL ST 038535,952,269,39794089 × 1420 × 25663 739
TRX VL TA 038535,952,269,39794089 × 1420 × 25663 739
TRX BD MC 04004160,782,18463750 × 1400 × 26463 260
TRX BD ST 04004160,782,18463750 × 1400 × 26463 240
TRX BD TA 04004160,782,18463750 × 1400 × 26463 240
TRX CU LS 0400–––1 370–4 925
TRX CU MC 0400–––1 370–4 925
TRX CU ST 0400–––1 370–4 925
TRX CU TA 0400–––1 370–4 925
TRX P LS 04003754718194050 × 1600 × 26153 846
TRX P MC 04003754718194050 × 1600 × 26153 846
TRX P ST 04003754718194050 × 1600 × 26153 986
TRX P TA 04003754718194050 × 1600 × 26153 986
TRX QZ TA 0400294255,8350–4 000
TRX SC MC 04003653,270,61 370–4 925
TRX SC ST 04003653,270,61 370–4 925
TRX SC TA 04003653,270,61 370–4 925
TRX SD TA 040041,159,881,28463750 × 1400 × 26463 593
TRX VL ST 0400–––8104640 × 1600 × 27504 500
TRX YC TA 041241,16080,78104640 × 1600 × 27504 200
TRX VL MC 041538,35674,39794089 × 1420 × 25663 764
TRX VL ST 041538,35674,39794089 × 1420 × 25663 739
TRX VL TA 041538,35674,39794089 × 1420 × 25663 739

400 kVA generator qanday yuklamalarni ta’minlaydi?

0,8 quvvat koeffitsiyentida 400 kVA taxminan 320 kW aktiv quvvatga to‘g‘ri keladi. 400 V uch fazali tarmoqda to‘liq yuklama toki taxminan 577 A.

Ushbu quvvat oralig‘idagi generatorlar odatda quyidagilar uchun ishlatiladi:

  • Fabrika va ishlab chiqarish korxonalari
  • Shifoxonalar, savdo markazlari va yirik tijorat binolari
  • Server xonalari va telekom markazlari
  • Yirik qurilish maydonlari va infratuzilma loyihalari

Misollar umumiy ma’lumot uchun; bir xil quvvat har bir obyektda bir xil yuklamani ta’minlamaydi. Tanlov ulanadigan uskunalarning umumiy quvvati, dvigatellarning ishga tushirish toklari va bir vaqtda ishlash ulushiga qarab qilinishi kerak.

Kerakli quvvatni uskunalar ro‘yxati bo‘yicha hisoblash uchun: Quvvatni hisoblash

400 kVA generator narxini belgilovchi omillar

Bir xil quvvatdagi ikki generatorning narxi tanlangan jihozlarga qarab farq qilishi mumkin. Asosiy omillar:

  • Dvigatel markasi va modeli
  • Alternator markasi va modeli
  • Korpus turi: shovqin izolyatsiyali kabina yoki ochiq turdagi
  • Boshqaruv paneli va avtomatik o‘tkazish paneli (ATS)
  • Yoqilg‘i baki hajmi
  • Yetkazib berish joyi va tashish

Yozma narx taklifi quvvat ehtiyojingiz va tanlagan jihozlaringizni yuborganingizdan so‘ng tayyorlanadi.

Narx va yetkazib berish muddatini bilishQo‘ng‘iroq +90 216 634 34 06

Ko‘p beriladigan savollar

400 kVA generator necha kW?

0,8 quvvat koeffitsiyentida 400 kVA 320 kW aktiv quvvatga teng (kW = kVA × 0,8). Ushbu sahifadagi modellarning standby quvvati 244–332 kW oralig‘ida.

400 kVA generator soatiga qancha yoqilg‘i sarflaydi?

Ishlab chiqaruvchi ma’lumotlariga ko‘ra, ushbu sahifadagi modellar 75% yuklamada soatiga 40–60,7 litr yoqilg‘i sarflaydi. Sarf yuklama, dvigatel va ish sharoitlariga qarab o‘zgaradi; har bir modelning qiymatlari mahsulot sahifasida.

400 kVA generator narxi nimaga bog‘liq?

Narx dvigatel va alternator markasi, korpus turi (kabinali yoki ochiq), boshqaruv paneli va ATS, yoqilg‘i baki hajmi hamda yetkazib berish joyiga bog‘liq. Yozma narx taklifi quvvat ehtiyojingiz va tanlagan jihozlaringizni yuborganingizdan so‘ng tayyorlanadi.

400 kVA generator uchun taklif oling

Quvvat ehtiyojingiz, foydalanish rejimi (standby yoki prime) va yetkazib berish joyini yuboring; taklifni loyihangizga mos tayyorlaymiz.

Narx va yetkazib berish muddatini bilish

WhatsApp orqali yozing

Yuklab olish