50 kVA (40 kW) dizel generator

Ushbu sahifada standby quvvati 40–58 kVA (32–46,4 kW) bo‘lgan 43 ta dizel generator modeli keltirilgan. Ro‘yxatdagi quvvatlar: 40, 44, 46, 48, 50, 52, 55 va 58 kVA.

Narx va yetkazib berish muddatini bilishModellarni ko‘rish

Terex Diesel shovqin izolyatsiyali kabinali dizel generator

Taklif va ma’lumot so‘rovi

Quvvat ehtiyojingiz, foydalanish rejimi (standby yoki prime) va yetkazib berish joyini yuboring; taklifni loyihangizga mos tayyorlaymiz.

Biz bilan bevosita bog‘laning

Qo‘ng‘iroq +90 216 634 34 06WhatsApp +90 533 582 26 50

So‘rovingiz qabul qilindi. Tez orada Siz bilan bog‘lanamiz.

Yuborib bo‘lmadi. Iltimos, qayta urinib ko‘ring yoki bizga qo‘ng‘iroq qiling. Biz bilan bevosita ham bog‘lanishingiz mumkin: WhatsApp +90 533 582 26 50 · info@terexdiesel.com

Qisqa vaqt ichida juda ko‘p so‘rov yuborildi. Iltimos, bir necha daqiqadan so‘ng qayta urinib ko‘ring.

Telefon yoki elektron pochta (bittasi yetarli)

Turkiyadan tashqaridagi savdolar uchun shartlar

  • Jo‘natish

    Omborda mavjud modellar: 2–3 ish kuni; Perkins, Cummins, Volvo, Kubota, Scania va FPT Iveco: buyurtmadan keyin 3–4 hafta.

  • Turkiyadan tashqarida kafolat

    Barcha dvigatel markalarida 12 oy yoki 1 000 ish soati.

  • Sertifikatlar

    ISO 9001 · CE · TSE-HYB

  • Eksport hujjatlari

    Tijorat hisob-fakturasi va qadoqlash varaqasi tayyorlanadi; kelib chiqish sertifikati va xaridor talab qilgan boshqa hujjatlar so‘rov bo‘yicha rasmiylashtiriladi.

Eksport jarayoni va to‘lov

Asosiy ko‘rsatkichlar

Modellar soni
43
Standby quvvat diapazoni
40–58 kVA
Dvigatel markalari
Perkins, Baudouin, Cummins, FPT Iveco, Kofo, Kubota, Quartz, Yangdong
Yoqilg‘i sarfi (75% yuklama)
5,8–9,4 L/soat
Kabinali og‘irlik
836–1 330 kg
Odatiy kabinali o‘lchamlar (U × E × B)
2200 × 1000 × 1550 mm

Qiymatlar ushbu sahifadagi modellarning texnik ma’lumotlaridan hisoblangan; har bir modelning qiymatlari mahsulot sahifasida.

Standby quvvati 40–58 kVA bo‘lgan modellar

Jadvalda har bir modelning standby va prime quvvati, dvigateli va alternatori ko‘rsatilgan; texnik ma’lumotlar uchun model nomini bosing. Modellarni yonma-yon ko‘rish uchun jadvaldagi solishtirish tugmasidan foydalaning.

Standby quvvati 40–58 kVA bo‘lgan modellar
ModelStandby (kVA)Prime (kVA)DvigatelAlternatorChastotaSolishtirishBatafsil
TRX CU LS 00404035Cummins X2.7TAA-G8Leroy-Somer TAL042 F50 HzBatafsil: TRX CU LS 0040Taklif so‘rash: TRX CU LS 0040
TRX CU MC 00404035Cummins X2.7TAA-G8Mecc Alte ECP32-2S/450 HzBatafsil: TRX CU MC 0040Taklif so‘rash: TRX CU MC 0040
TRX CU ST 00404035Cummins X2.7TAA-G8Stamford S1L2J150 HzBatafsil: TRX CU ST 0040Taklif so‘rash: TRX CU ST 0040
TRX CU TA 00404035Cummins X2.7TAA-G8Terex TA180-34N250 HzBatafsil: TRX CU TA 0040Taklif so‘rash: TRX CU TA 0040
TRX YD TA 00404035Yangdong Y4102DTerex TA180-34N250 HzBatafsil: TRX YD TA 0040Taklif so‘rash: TRX YD TA 0040
TRX BD MC 00444440Baudouin 4M06G8D0/SMecc Alte ECP32-2S/450 HzBatafsil: TRX BD MC 0044Taklif so‘rash: TRX BD MC 0044
TRX BD ST 00444440Baudouin 4M06G8D0/SStamford S1L2-N50 HzBatafsil: TRX BD ST 0044Taklif so‘rash: TRX BD ST 0044
TRX BD TA 00444440Baudouin 4M06G8D0/STerex TA180-34N250 HzBatafsil: TRX BD TA 0044Taklif so‘rash: TRX BD TA 0044
TRX CU LS 00444440Cummins X2.7TAA-G8Leroy-Somer TAL042 F50 HzBatafsil: TRX CU LS 0044Taklif so‘rash: TRX CU LS 0044
TRX CU MC 00444440Cummins X2.7TAA-G8Mecc Alte ECP32-2S/450 HzBatafsil: TRX CU MC 0044Taklif so‘rash: TRX CU MC 0044
TRX CU ST 00444440Cummins X2.7TAA-G8Stamford S1L2K150 HzBatafsil: TRX CU ST 0044Taklif so‘rash: TRX CU ST 0044
TRX CU TA 00444440Cummins X2.7TAA-G8Terex TA180-34N250 HzBatafsil: TRX CU TA 0044Taklif so‘rash: TRX CU TA 0044
TRX IV LS 00444440FPT Iveco R24Leroy-Somer TAL042 F50 HzBatafsil: TRX IV LS 0044Taklif so‘rash: TRX IV LS 0044
TRX IV MC 00444440FPT Iveco R24Mecc Alte ECP32-2S/450 HzBatafsil: TRX IV MC 0044Taklif so‘rash: TRX IV MC 0044
TRX IV ST 00444440FPT Iveco R24Stamford S1L2-N50 HzBatafsil: TRX IV ST 0044Taklif so‘rash: TRX IV ST 0044
TRX IV TA 00444440FPT Iveco R24Terex TA180-34N250 HzBatafsil: TRX IV TA 0044Taklif so‘rash: TRX IV TA 0044
TRX KF TA 00444440Kofo MN4100ZDS-42Terex TA180-34N250 HzBatafsil: TRX KF TA 0044Taklif so‘rash: TRX KF TA 0044
TRX YD TA 00444440Yangdong Y4105DTerex TA180-34N250 HzBatafsil: TRX YD TA 0044Taklif so‘rash: TRX YD TA 0044
TRX QZ TA 00464641,4Quartz Q4100DTerex TA180-34N250 HzBatafsil: TRX QZ TA 0046Taklif so‘rash: TRX QZ TA 0046
TRX KB TA 00484845Kubota V3800DI-T-E2BGTerex TA180-34N250 HzBatafsil: TRX KB TA 0048Taklif so‘rash: TRX KB TA 0048
TRX BD MC 00505045Baudouin 4M06G50/5Mecc Alte ECP32-2S/450 HzBatafsil: TRX BD MC 0050Taklif so‘rash: TRX BD MC 0050
TRX BD ST 00505045Baudouin 4M06G50/5Stamford S1L2-N50 HzBatafsil: TRX BD ST 0050Taklif so‘rash: TRX BD ST 0050
TRX BD TA 00505045Baudouin 4M06G50/5Terex TA180-34N250 HzBatafsil: TRX BD TA 0050Taklif so‘rash: TRX BD TA 0050
TRX P LS 00505045Perkins 1103A-33TG1Leroy-Somer TAL042 F50 HzBatafsil: TRX P LS 0050Taklif so‘rash: TRX P LS 0050
TRX P MC 00505045Perkins 1103A-33TG1Mecc Alte ECP32-2S/450 HzBatafsil: TRX P MC 0050Taklif so‘rash: TRX P MC 0050
TRX P ST 00505045Perkins 1103A-33TG1Stamford S1L2-N50 HzBatafsil: TRX P ST 0050Taklif so‘rash: TRX P ST 0050
TRX P TA 00505045Perkins 1103A-33TG1Terex TA180-34N250 HzBatafsil: TRX P TA 0050Taklif so‘rash: TRX P TA 0050
TRX YD TA 00505045Yangdong Y4110DTerex TA180-34N250 HzBatafsil: TRX YD TA 0050Taklif so‘rash: TRX YD TA 0050
TRX QZ TA 00525246,8Quartz Q4100ZDTerex TA180-34N250 HzBatafsil: TRX QZ TA 0052Taklif so‘rash: TRX QZ TA 0052
TRX BD MC 00555550Baudouin 4M06G10D0/SMecc Alte ECP32-2M50 HzBatafsil: TRX BD MC 0055Taklif so‘rash: TRX BD MC 0055
TRX BD ST 00555550Baudouin 4M06G10D0/SStamford S1L2-Y50 HzBatafsil: TRX BD ST 0055Taklif so‘rash: TRX BD ST 0055
TRX BD TA 00555550Baudouin 4M06G10D0/STerex TA180-40N250 HzBatafsil: TRX BD TA 0055Taklif so‘rash: TRX BD TA 0055
TRX CU LS 00555550Cummins 4BTAA3.3G11Leroy-Somer TAL042 H50 HzBatafsil: TRX CU LS 0055Taklif so‘rash: TRX CU LS 0055
TRX CU MC 00555550Cummins 4BTAA3.3G11Mecc Alte ECP32-2M50 HzBatafsil: TRX CU MC 0055Taklif so‘rash: TRX CU MC 0055
TRX CU ST 00555550Cummins 4BTAA3.3G11Stamford S2L1D-D450 HzBatafsil: TRX CU ST 0055Taklif so‘rash: TRX CU ST 0055
TRX CU TA 00555550Cummins 4BTAA3.3G11Terex TA180-40N250 HzBatafsil: TRX CU TA 0055Taklif so‘rash: TRX CU TA 0055
TRX IV LS 00555550FPT Iveco NEF45AM2Leroy-Somer TAL042 H50 HzBatafsil: TRX IV LS 0055Taklif so‘rash: TRX IV LS 0055
TRX IV MC 00555550FPT Iveco NEF45AM2Mecc Alte ECP32-2M50 HzBatafsil: TRX IV MC 0055Taklif so‘rash: TRX IV MC 0055
TRX IV ST 00555550FPT Iveco NEF45AM2Stamford S1L2-N50 HzBatafsil: TRX IV ST 0055Taklif so‘rash: TRX IV ST 0055
TRX IV TA 00555550FPT Iveco NEF45AM2Terex TA180-40N250 HzBatafsil: TRX IV TA 0055Taklif so‘rash: TRX IV TA 0055
TRX KF TA 00555550Kofo MN4100ZDS-46Terex TA180-36N250 HzBatafsil: TRX KF TA 0055Taklif so‘rash: TRX KF TA 0055
TRX YD TA 00555550Yangdong Y4102ZLDTerex TA180-36N250 HzBatafsil: TRX YD TA 0055Taklif so‘rash: TRX YD TA 0055
TRX QZ TA 00585852,2Quartz Q4105DTerex TA180-36N250 HzBatafsil: TRX QZ TA 0058Taklif so‘rash: TRX QZ TA 0058

Kerakli quvvatni bilmaysizmi? Birgalikda hisoblaymiz

Yoqilg‘i sarfi, bak, o‘lchamlar va og‘irlik

Qiymatlar mahsulot ma’lumotlarimizdan olingan. O‘lcham, og‘irlik va bak ustunlari Kabinali (shovqin izolyatsiyali) korpus uchun; ma’lumot yo‘q maydonlar "–" bilan ko‘rsatiladi.

Model50% yuklamada (L/soat)75% yuklamada (L/soat)100% yuklamada (L/soat)Yoqilg‘i baki (L)O‘lchamlar (U × E × B) (mm)Og‘irlik (kg)
TRX CU LS 0040–––1252200 × 1000 × 15501 095
TRX CU MC 0040–––1252200 × 1000 × 15501 095
TRX CU ST 0040–––1252200 × 1000 × 15501 095
TRX CU TA 0040–––1252200 × 1000 × 15501 095
TRX YD TA 00404,867,61012300 × 1000 × 1545841
TRX BD MC 00444,779,51012300 × 1000 × 1545861
TRX BD ST 00444,779,51012300 × 1000 × 1545870
TRX BD TA 00444,779,51012300 × 1000 × 1545870
TRX CU LS 0044–––1252200 × 1000 × 15501 095
TRX CU MC 0044–––1252200 × 1000 × 15501 095
TRX CU ST 0044–––1252200 × 1000 × 15501 095
TRX CU TA 0044–––1252200 × 1000 × 15501 095
TRX IV LS 00446,2–10,21252200 × 1000 × 1550995
TRX IV MC 00446,2–10,21252200 × 1000 × 1550995
TRX IV ST 00446,2–10,21252200 × 1000 × 1550995
TRX IV TA 00446,2–10,21252200 × 1000 × 1550995
TRX KF TA 00446,29,111,51252350 × 1000 × 1550975
TRX YD TA 00445,66,88,81012300 × 1000 × 1545851
TRX QZ TA 00463,95,87,81252200 × 1000 × 15501 195
TRX KB TA 00485,57,210,31352225 × 950 × 16601 060
TRX BD MC 00505,4810,71012300 × 1000 × 1545836
TRX BD ST 00505,4810,71012300 × 1000 × 1545900
TRX BD TA 00505,4810,71012300 × 1000 × 1545900
TRX P LS 00505,78,210,71012300 × 1000 × 1545985
TRX P MC 00505,78,210,71012300 × 1000 × 1545969
TRX P ST 00505,78,210,71012300 × 1000 × 1545998
TRX P TA 00505,78,210,71012300 × 1000 × 1545998
TRX YD TA 00506,99,2121001800 × 1000 × 12501 330
TRX QZ TA 00526,47,49,91252200 × 1000 × 15501 250
TRX BD MC 005568,911,91012300 × 1000 × 1545844
TRX BD ST 005568,911,91012300 × 1000 × 1545898
TRX BD TA 005568,911,91012300 × 1000 × 1545898
TRX CU LS 0055–9,412,31252200 × 1000 × 15501 095
TRX CU MC 0055–9,412,31252200 × 1000 × 15501 095
TRX CU ST 0055–9,412,31252200 × 1000 × 15501 095
TRX CU TA 0055–9,412,31252200 × 1000 × 15501 095
TRX IV LS 0055–––1252200 × 1000 × 15501 095
TRX IV MC 0055–––1252200 × 1000 × 15501 095
TRX IV ST 0055–––1252200 × 1000 × 15501 095
TRX IV TA 0055–––1252200 × 1000 × 15501 095
TRX KF TA 005569121252350 × 1000 × 15501 035
TRX YD TA 00556,78,510,81012300 × 1000 × 1545934
TRX QZ TA 00585,5810,92202440 × 1000 × 18601 310

50 kVA generator qanday yuklamalarni ta’minlaydi?

0,8 quvvat koeffitsiyentida 50 kVA taxminan 40 kW aktiv quvvatga to‘g‘ri keladi. 400 V uch fazali tarmoqda to‘liq yuklama toki taxminan 72 A.

Ushbu quvvat oralig‘idagi generatorlar odatda quyidagilar uchun ishlatiladi:

  • Do‘konlar, restoran va kafelar
  • Ko‘p qavatli uylarning umumiy tizimlari (lift, nasos, yoritish)
  • Ustaxonalar va kichik ishlab chiqarish
  • Sug‘orish nasoslari

Misollar umumiy ma’lumot uchun; bir xil quvvat har bir obyektda bir xil yuklamani ta’minlamaydi. Tanlov ulanadigan uskunalarning umumiy quvvati, dvigatellarning ishga tushirish toklari va bir vaqtda ishlash ulushiga qarab qilinishi kerak.

Kerakli quvvatni uskunalar ro‘yxati bo‘yicha hisoblash uchun: Quvvatni hisoblash

50 kVA generator narxini belgilovchi omillar

Bir xil quvvatdagi ikki generatorning narxi tanlangan jihozlarga qarab farq qilishi mumkin. Asosiy omillar:

  • Dvigatel markasi va modeli
  • Alternator markasi va modeli
  • Korpus turi: shovqin izolyatsiyali kabina yoki ochiq turdagi
  • Boshqaruv paneli va avtomatik o‘tkazish paneli (ATS)
  • Yoqilg‘i baki hajmi
  • Yetkazib berish joyi va tashish

Yozma narx taklifi quvvat ehtiyojingiz va tanlagan jihozlaringizni yuborganingizdan so‘ng tayyorlanadi.

Narx va yetkazib berish muddatini bilishQo‘ng‘iroq +90 216 634 34 06

Ko‘p beriladigan savollar

50 kVA generator necha kW?

0,8 quvvat koeffitsiyentida 50 kVA 40 kW aktiv quvvatga teng (kW = kVA × 0,8). Ushbu sahifadagi modellarning standby quvvati 32–46,4 kW oralig‘ida.

50 kVA generator soatiga qancha yoqilg‘i sarflaydi?

Ishlab chiqaruvchi ma’lumotlariga ko‘ra, ushbu sahifadagi modellar 75% yuklamada soatiga 5,8–9,4 litr yoqilg‘i sarflaydi. Sarf yuklama, dvigatel va ish sharoitlariga qarab o‘zgaradi; har bir modelning qiymatlari mahsulot sahifasida.

50 kVA generator narxi nimaga bog‘liq?

Narx dvigatel va alternator markasi, korpus turi (kabinali yoki ochiq), boshqaruv paneli va ATS, yoqilg‘i baki hajmi hamda yetkazib berish joyiga bog‘liq. Yozma narx taklifi quvvat ehtiyojingiz va tanlagan jihozlaringizni yuborganingizdan so‘ng tayyorlanadi.

50 kVA generator uchun taklif oling

Quvvat ehtiyojingiz, foydalanish rejimi (standby yoki prime) va yetkazib berish joyini yuboring; taklifni loyihangizga mos tayyorlaymiz.

Narx va yetkazib berish muddatini bilish

WhatsApp orqali yozing

Yuklab olish