30 kVA (24 kW) dizel generator

Ushbu sahifada standby quvvati 25–38 kVA (20–30,4 kW) bo‘lgan 32 ta dizel generator modeli keltirilgan. Ro‘yxatdagi quvvatlar: 25, 27,5, 28, 30, 31,4, 33, 35 va 38 kVA.

Narx va yetkazib berish muddatini bilishModellarni ko‘rish

Terex Diesel kichik quvvatli shovqin izolyatsiyali kabinali dizel generator

Taklif va ma’lumot so‘rovi

Quvvat ehtiyojingiz, foydalanish rejimi (standby yoki prime) va yetkazib berish joyini yuboring; taklifni loyihangizga mos tayyorlaymiz.

Biz bilan bevosita bog‘laning

Qo‘ng‘iroq +90 216 634 34 06WhatsApp +90 533 582 26 50

So‘rovingiz qabul qilindi. Tez orada Siz bilan bog‘lanamiz.

Yuborib bo‘lmadi. Iltimos, qayta urinib ko‘ring yoki bizga qo‘ng‘iroq qiling. Biz bilan bevosita ham bog‘lanishingiz mumkin: WhatsApp +90 533 582 26 50 · info@terexdiesel.com

Qisqa vaqt ichida juda ko‘p so‘rov yuborildi. Iltimos, bir necha daqiqadan so‘ng qayta urinib ko‘ring.

Telefon yoki elektron pochta (bittasi yetarli)

Turkiyadan tashqaridagi savdolar uchun shartlar

  • Jo‘natish

    Omborda mavjud modellar: 2–3 ish kuni; Perkins, Cummins, Volvo, Kubota, Scania va FPT Iveco: buyurtmadan keyin 3–4 hafta.

  • Turkiyadan tashqarida kafolat

    Barcha dvigatel markalarida 12 oy yoki 1 000 ish soati.

  • Sertifikatlar

    ISO 9001 · CE · TSE-HYB

  • Eksport hujjatlari

    Tijorat hisob-fakturasi va qadoqlash varaqasi tayyorlanadi; kelib chiqish sertifikati va xaridor talab qilgan boshqa hujjatlar so‘rov bo‘yicha rasmiylashtiriladi.

Eksport jarayoni va to‘lov

Asosiy ko‘rsatkichlar

Modellar soni
32
Standby quvvat diapazoni
25–38 kVA
Dvigatel markalari
Perkins, Baudouin, Cummins, FPT Iveco, Kofo, Kubota, Quartz, Yangdong, Yuchai
Yoqilg‘i sarfi (75% yuklama)
4–6,6 L/soat
Kabinali og‘irlik
689–1 065 kg
Odatiy kabinali o‘lchamlar (U × E × B)
1800 × 1000 × 1250 mm

Qiymatlar ushbu sahifadagi modellarning texnik ma’lumotlaridan hisoblangan; har bir modelning qiymatlari mahsulot sahifasida.

Standby quvvati 25–38 kVA bo‘lgan modellar

Jadvalda har bir modelning standby va prime quvvati, dvigateli va alternatori ko‘rsatilgan; texnik ma’lumotlar uchun model nomini bosing. Modellarni yonma-yon ko‘rish uchun jadvaldagi solishtirish tugmasidan foydalaning.

Standby quvvati 25–38 kVA bo‘lgan modellar
ModelStandby (kVA)Prime (kVA)DvigatelAlternatorChastotaSolishtirishBatafsil
TRX BD MC 00252523Baudouin 4M06G4D0/SMecc Alte ECP28-VL/450 HzBatafsil: TRX BD MC 0025Taklif so‘rash: TRX BD MC 0025
TRX BD ST 00252523Baudouin 4M06G4D0/SStamford S0L2-P50 HzBatafsil: TRX BD ST 0025Taklif so‘rash: TRX BD ST 0025
TRX BD TA 00252523Baudouin 4M06G4D0/STerex TA180-24N250 HzBatafsil: TRX BD TA 0025Taklif so‘rash: TRX BD TA 0025
TRX KF TA 00252522Kofo 4YT23-20DTerex TA160-16N250 HzBatafsil: TRX KF TA 0025Taklif so‘rash: TRX KF TA 0025
TRX QZ TA 00252522,5Quartz Q490Terex TA160-16N250 HzBatafsil: TRX QZ TA 0025Taklif so‘rash: TRX QZ TA 0025
TRX YD TA 00252522Yangdong YSD490DTerex TA160-16N250 HzBatafsil: TRX YD TA 0025Taklif so‘rash: TRX YD TA 0025
TRX CU LS 002727,525Cummins X2.7TAA-G1Leroy-Somer TAL042 C50 HzBatafsil: TRX CU LS 0027Taklif so‘rash: TRX CU LS 0027
TRX CU MC 002727,525Cummins X2.7TAA-G1Mecc Alte ECP32-2S/450 HzBatafsil: TRX CU MC 0027Taklif so‘rash: TRX CU MC 0027
TRX CU ST 002727,525Cummins X2.7TAA-G1Stamford SOL2-M150 HzBatafsil: TRX CU ST 0027Taklif so‘rash: TRX CU ST 0027
TRX CU TA 002727,525Cummins X2.7TAA-G1Terex TA180-24N250 HzBatafsil: TRX CU TA 0027Taklif so‘rash: TRX CU TA 0027
TRX YD TA 00282825Yangdong Y490DTerex TA180-22N250 HzBatafsil: TRX YD TA 0028Taklif so‘rash: TRX YD TA 0028
TRX YD TA 00303027Yangdong Y495DTerex TA180-24N250 HzBatafsil: TRX YD TA 0030Taklif so‘rash: TRX YD TA 0030
TRX KB TA 003131,429,1Kubota V3300-E2BG2Terex TA180-24N250 HzBatafsil: TRX KB TA 0031Taklif so‘rash: TRX KB TA 0031
TRX CU LS 00333330Cummins X2.7TAA-G2Leroy-Somer TAL042 C50 HzBatafsil: TRX CU LS 0033Taklif so‘rash: TRX CU LS 0033
TRX CU MC 00333330Cummins X2.7TAA-G2Mecc Alte ECP32-2S/450 HzBatafsil: TRX CU MC 0033Taklif so‘rash: TRX CU MC 0033
TRX CU ST 00333330Cummins X2.7TAA-G2Stamford SOL2-P150 HzBatafsil: TRX CU ST 0033Taklif so‘rash: TRX CU ST 0033
TRX CU TA 00333330Cummins X2.7TAA-G2Terex TA180-24N250 HzBatafsil: TRX CU TA 0033Taklif so‘rash: TRX CU TA 0033
TRX IV LS 00333330FPT Iveco R24Leroy-Somer TAL042 C50 HzBatafsil: TRX IV LS 0033Taklif so‘rash: TRX IV LS 0033
TRX IV MC 00333330FPT Iveco R24Mecc Alte ECP28-VL/450 HzBatafsil: TRX IV MC 0033Taklif so‘rash: TRX IV MC 0033
TRX IV ST 00333330FPT Iveco R24Stamford S0L2-P50 HzBatafsil: TRX IV ST 0033Taklif so‘rash: TRX IV ST 0033
TRX IV TA 00333330FPT Iveco R24Terex TA180-24N250 HzBatafsil: TRX IV TA 0033Taklif so‘rash: TRX IV TA 0033
TRX P LS 00333330Perkins 1103A-33GLeroy-Somer TAL042 C50 HzBatafsil: TRX P LS 0033Taklif so‘rash: TRX P LS 0033
TRX P MC 00333330Perkins 1103A-33GMecc Alte ECP28-VL/450 HzBatafsil: TRX P MC 0033Taklif so‘rash: TRX P MC 0033
TRX P ST 00333330Perkins 1103A-33GStamford S0L2-P50 HzBatafsil: TRX P ST 0033Taklif so‘rash: TRX P ST 0033
TRX P TA 00333330Perkins 1103A-33GTerex TA180-24N250 HzBatafsil: TRX P TA 0033Taklif so‘rash: TRX P TA 0033
TRX YC TA 00333330Yuchai YC4V45Z-D20Terex TA180-24N250 HzBatafsil: TRX YC TA 0033Taklif so‘rash: TRX YC TA 0033
TRX YD TA 00333330Yangdong Y4100DTerex TA180-24N250 HzBatafsil: TRX YD TA 0033Taklif so‘rash: TRX YD TA 0033
TRX BD MC 00353532Baudouin 4M06G6D0/SMecc Alte ECP32-2S/450 HzBatafsil: TRX BD MC 0035Taklif so‘rash: TRX BD MC 0035
TRX BD ST 00353532Baudouin 4M06G6D0/SStamford S0L2-P50 HzBatafsil: TRX BD ST 0035Taklif so‘rash: TRX BD ST 0035
TRX BD TA 00353532Baudouin 4M06G6D0/STerex TA180-34N250 HzBatafsil: TRX BD TA 0035Taklif so‘rash: TRX BD TA 0035
TRX KF TA 00353532Kofo MN4100DS-30Terex TA180-24N250 HzBatafsil: TRX KF TA 0035Taklif so‘rash: TRX KF TA 0035
TRX QZ TA 00383834,2Quartz Q490ZDTerex TA180-24N250 HzBatafsil: TRX QZ TA 0038Taklif so‘rash: TRX QZ TA 0038

Kerakli quvvatni bilmaysizmi? Birgalikda hisoblaymiz

Yoqilg‘i sarfi, bak, o‘lchamlar va og‘irlik

Qiymatlar mahsulot ma’lumotlarimizdan olingan. O‘lcham, og‘irlik va bak ustunlari Kabinali (shovqin izolyatsiyali) korpus uchun; ma’lumot yo‘q maydonlar "–" bilan ko‘rsatiladi.

Model50% yuklamada (L/soat)75% yuklamada (L/soat)100% yuklamada (L/soat)Yoqilg‘i baki (L)O‘lchamlar (U × E × B) (mm)Og‘irlik (kg)
TRX BD MC 00253,24,56,1821950 × 900 × 1337690
TRX BD ST 00253,24,56,1821950 × 900 × 1337689
TRX BD TA 00253,24,56,1821950 × 900 × 1337689
TRX KF TA 00253451001800 × 1000 × 1250690
TRX QZ TA 00253,656,61252200 × 1000 × 1550945
TRX YD TA 00254,75,66,41001800 × 1000 × 1250798
TRX CU LS 0027–––1001800 × 1000 × 1250755
TRX CU MC 0027–––1001800 × 1000 × 1250755
TRX CU ST 0027–––1001800 × 1000 × 1250755
TRX CU TA 0027–––1001800 × 1000 × 1250755
TRX YD TA 00284,85,86,4821950 × 900 × 1337747
TRX YD TA 00305,36,26,91001800 × 1000 × 1250997
TRX KB TA 00313,65,47,21352225 × 950 × 16601 000
TRX CU LS 0033–––1001800 × 1000 × 1250765
TRX CU MC 0033–––1001800 × 1000 × 1250765
TRX CU ST 0033–––1001800 × 1000 × 1250765
TRX CU TA 0033–––1001800 × 1000 × 1250765
TRX IV LS 00333,14,95,81001800 × 1000 × 1250765
TRX IV MC 00333,14,95,81001800 × 1000 × 1250765
TRX IV ST 00333,14,95,81001800 × 1000 × 1250765
TRX IV TA 00333,14,95,81001800 × 1000 × 1250765
TRX P LS 00333,95,47,11012300 × 1000 × 1545919
TRX P MC 00333,95,47,11012300 × 1000 × 1545928
TRX P ST 00333,95,47,11012300 × 1000 × 1545918
TRX P TA 00333,95,47,11012300 × 1000 × 1545918
TRX YC TA 0033–––1352225 × 950 × 16601 010
TRX YD TA 003345,77,31001800 × 1000 × 12501 065
TRX BD MC 003545,77,61012300 × 1000 × 1545872
TRX BD ST 003545,77,61012300 × 1000 × 1545896
TRX BD TA 003545,77,61012300 × 1000 × 1545896
TRX KF TA 003534,35,71252350 × 1000 × 1550955
TRX QZ TA 003856,67,21252200 × 1000 × 15501 045

30 kVA generator qanday yuklamalarni ta’minlaydi?

0,8 quvvat koeffitsiyentida 30 kVA taxminan 24 kW aktiv quvvatga to‘g‘ri keladi. 400 V uch fazali tarmoqda to‘liq yuklama toki taxminan 43 A.

Ushbu quvvat oralig‘idagi generatorlar odatda quyidagilar uchun ishlatiladi:

  • Xususiy uylar va villalar
  • Kichik do‘konlar va ofislar
  • Qurilish konteynerlari va maydon ofislari
  • Kichik ustaxonalar

Misollar umumiy ma’lumot uchun; bir xil quvvat har bir obyektda bir xil yuklamani ta’minlamaydi. Tanlov ulanadigan uskunalarning umumiy quvvati, dvigatellarning ishga tushirish toklari va bir vaqtda ishlash ulushiga qarab qilinishi kerak.

Kerakli quvvatni uskunalar ro‘yxati bo‘yicha hisoblash uchun: Quvvatni hisoblash

30 kVA generator narxini belgilovchi omillar

Bir xil quvvatdagi ikki generatorning narxi tanlangan jihozlarga qarab farq qilishi mumkin. Asosiy omillar:

  • Dvigatel markasi va modeli
  • Alternator markasi va modeli
  • Korpus turi: shovqin izolyatsiyali kabina yoki ochiq turdagi
  • Boshqaruv paneli va avtomatik o‘tkazish paneli (ATS)
  • Yoqilg‘i baki hajmi
  • Yetkazib berish joyi va tashish

Yozma narx taklifi quvvat ehtiyojingiz va tanlagan jihozlaringizni yuborganingizdan so‘ng tayyorlanadi.

Narx va yetkazib berish muddatini bilishQo‘ng‘iroq +90 216 634 34 06

Ko‘p beriladigan savollar

30 kVA generator necha kW?

0,8 quvvat koeffitsiyentida 30 kVA 24 kW aktiv quvvatga teng (kW = kVA × 0,8). Ushbu sahifadagi modellarning standby quvvati 20–30,4 kW oralig‘ida.

30 kVA generator soatiga qancha yoqilg‘i sarflaydi?

Ishlab chiqaruvchi ma’lumotlariga ko‘ra, ushbu sahifadagi modellar 75% yuklamada soatiga 4–6,6 litr yoqilg‘i sarflaydi. Sarf yuklama, dvigatel va ish sharoitlariga qarab o‘zgaradi; har bir modelning qiymatlari mahsulot sahifasida.

30 kVA generator narxi nimaga bog‘liq?

Narx dvigatel va alternator markasi, korpus turi (kabinali yoki ochiq), boshqaruv paneli va ATS, yoqilg‘i baki hajmi hamda yetkazib berish joyiga bog‘liq. Yozma narx taklifi quvvat ehtiyojingiz va tanlagan jihozlaringizni yuborganingizdan so‘ng tayyorlanadi.

30 kVA generator uchun taklif oling

Quvvat ehtiyojingiz, foydalanish rejimi (standby yoki prime) va yetkazib berish joyini yuboring; taklifni loyihangizga mos tayyorlaymiz.

Narx va yetkazib berish muddatini bilish

WhatsApp orqali yozing

Yuklab olish