75 kVA (60 kW) Diesel Generator

This page lists 42 diesel generator models with standby ratings of 66–88 kVA (52.8–70.4 kW). Ratings listed: 66, 68.8, 72, 75, 76, 77, 80, 82, and 88 kVA.

Get price and lead timeView models

Terex Diesel canopied diesel generator

Request a quote

Tell us your power requirement, duty (standby or prime) and delivery location, and we will prepare a quote for your project.

Contact us directly

Call +90 216 634 34 06WhatsApp +90 533 582 26 50

Your request has been received. We will contact you as soon as possible.

Could not send. Please try again or call us. You can also reach us directly: WhatsApp +90 533 582 26 50 · info@terexdiesel.com

Too many submissions in a short time. Please try again in a few minutes.

Phone or email (one is enough)

Terms for sales outside Türkiye

  • Dispatch

    Models in stock: 2–3 business days; Perkins, Cummins, Volvo, Kubota, Scania and FPT Iveco: 3–4 weeks after order.

  • Warranty outside Türkiye

    12 months or 1,000 operating hours for all engine brands.

  • Certificates

    ISO 9001 · CE · TSE-HYB

  • Export documents

    A commercial invoice and packing list are prepared; a certificate of origin and any other documents the buyer requires are issued on request.

Export Process and Payment

Key figures

Models
42
Standby power range
66–88 kVA
Engine brands
Perkins, Baudouin, Cummins, FPT Iveco, Kofo, Quartz, SDEC, Yangdong, Yuchai
Fuel consumption (75% load)
9.7–15.4 L/h
Weight with canopy
973–1,560 kg
Typical canopy dimensions (L × W × H)
2440 × 1000 × 1860 mm

Figures are calculated from the technical data of the models on this page; per-model values are on each product page.

Models rated 66–88 kVA standby

The table shows each model’s standby and prime ratings, engine and alternator; click a model name for full specifications. Use the compare button in the table to view models side by side.

Models rated 66–88 kVA standby
ModelStandby (kVA)Prime (kVA)EngineAlternatorFrequencyCompareView
TRX CU LS 00666662Cummins 4BTAA3.3G11Leroy-Somer TAL042 H50 HzView: TRX CU LS 0066Request a Quote: TRX CU LS 0066
TRX CU MC 00666662Cummins 4BTAA3.3G11Mecc Alte ECP32-2M50 HzView: TRX CU MC 0066Request a Quote: TRX CU MC 0066
TRX CU ST 00666662Cummins 4BTAA3.3G11Stamford S2L1D-D450 HzView: TRX CU ST 0066Request a Quote: TRX CU ST 0066
TRX CU TA 00666662Cummins 4BTAA3.3G11Terex TA180-40N250 HzView: TRX CU TA 0066Request a Quote: TRX CU TA 0066
TRX IV LS 00666660FPT Iveco NEF45SM1ALeroy-Somer TAL042 H50 HzView: TRX IV LS 0066Request a Quote: TRX IV LS 0066
TRX IV MC 00666660FPT Iveco NEF45SM1AMecc Alte ECP32-2M50 HzView: TRX IV MC 0066Request a Quote: TRX IV MC 0066
TRX IV ST 00666660FPT Iveco NEF45SM1AStamford S1L2-Y50 HzView: TRX IV ST 0066Request a Quote: TRX IV ST 0066
TRX IV TA 00666660FPT Iveco NEF45SM1ATerex TA180-40N250 HzView: TRX IV TA 0066Request a Quote: TRX IV TA 0066
TRX P LS 00666660Perkins 1103A-33TG2Leroy-Somer TAL042 H50 HzView: TRX P LS 0066Request a Quote: TRX P LS 0066
TRX P MC 00666660Perkins 1103A-33TG2Mecc Alte ECP32-2M50 HzView: TRX P MC 0066Request a Quote: TRX P MC 0066
TRX P ST 00666660Perkins 1103A-33TG2Stamford S1L2-Y50 HzView: TRX P ST 0066Request a Quote: TRX P ST 0066
TRX P TA 00666660Perkins 1103A-33TG2Terex TA180-40N250 HzView: TRX P TA 0066Request a Quote: TRX P TA 0066
TRX YD TA 00666658Yangdong Y4105ZLDTerex TA180-36N250 HzView: TRX YD TA 0066Request a Quote: TRX YD TA 0066
TRX YC TA 006968.7562.5Yuchai YC4D90Z-D21Terex TA180-40N250 HzView: TRX YC TA 0069Request a Quote: TRX YC TA 0069
TRX BD MC 00727265Baudouin 4M10G2D0/SMecc Alte ECP32-2M50 HzView: TRX BD MC 0072Request a Quote: TRX BD MC 0072
TRX BD ST 00727265Baudouin 4M10G2D0/SStamford S1L2-Y50 HzView: TRX BD ST 0072Request a Quote: TRX BD ST 0072
TRX BD TA 00727265Baudouin 4M10G2D0/STerex TA180-40N250 HzView: TRX BD TA 0072Request a Quote: TRX BD TA 0072
TRX P LS 00727265Perkins 1104A-44TG1Leroy-Somer TAL044 A50 HzView: TRX P LS 0072Request a Quote: TRX P LS 0072
TRX P MC 00727265Perkins 1104A-44TG1Mecc Alte ECP32-2M50 HzView: TRX P MC 0072Request a Quote: TRX P MC 0072
TRX P ST 00727265Perkins 1104A-44TG1Stamford S1L2-Y50 HzView: TRX P ST 0072Request a Quote: TRX P ST 0072
TRX P TA 00727265Perkins 1104A-44TG1Terex TA180-40N250 HzView: TRX P TA 0072Request a Quote: TRX P TA 0072
TRX YD TA 00757568Yangdong YD4EZLDTerex TA180-40N250 HzView: TRX YD TA 0075Request a Quote: TRX YD TA 0075
TRX SD TA 00767669SDEC SC4H95D2Terex TA225-70N50 HzView: TRX SD TA 0076Request a Quote: TRX SD TA 0076
TRX KF TA 00777770Kofo MN4105ZDSTerex TA180-40N250 HzView: TRX KF TA 0077Request a Quote: TRX KF TA 0077
TRX QZ TA 00777769.3Quartz Q4105ZDTerex TA180-40N250 HzView: TRX QZ TA 0077Request a Quote: TRX QZ TA 0077
TRX YC TA 00808072.5Yuchai YC4A100Z-D20Terex TA225-70N50 HzView: TRX YC TA 0080Request a Quote: TRX YC TA 0080
TRX IV LS 00828274FPT Iveco NEF45SM2A-5Leroy-Somer TAL044 B50 HzView: TRX IV LS 0082Request a Quote: TRX IV LS 0082
TRX IV MC 00828274FPT Iveco NEF45SM2A-5Mecc Alte ECP32-2L/450 HzView: TRX IV MC 0082Request a Quote: TRX IV MC 0082
TRX IV ST 00828274FPT Iveco NEF45SM2A-5Stamford UCI224G50 HzView: TRX IV ST 0082Request a Quote: TRX IV ST 0082
TRX IV TA 00828274FPT Iveco NEF45SM2A-5Terex TA225-70N50 HzView: TRX IV TA 0082Request a Quote: TRX IV TA 0082
TRX BD MC 00888880Baudouin 4M10G4D0/SMecc Alte ECP32-2L/450 HzView: TRX BD MC 0088Request a Quote: TRX BD MC 0088
TRX BD ST 00888880Baudouin 4M10G4D0/SStamford UCI224G50 HzView: TRX BD ST 0088Request a Quote: TRX BD ST 0088
TRX BD TA 00888880Baudouin 4M10G4D0/STerex TA225-70N50 HzView: TRX BD TA 0088Request a Quote: TRX BD TA 0088
TRX IV LS 00888880FPT Iveco NEF45SM3Leroy-Somer TAL044 B50 HzView: TRX IV LS 0088Request a Quote: TRX IV LS 0088
TRX IV MC 00888880FPT Iveco NEF45SM3Mecc Alte ECP32-2L/450 HzView: TRX IV MC 0088Request a Quote: TRX IV MC 0088
TRX IV ST 00888880FPT Iveco NEF45SM3Stamford UCI224G50 HzView: TRX IV ST 0088Request a Quote: TRX IV ST 0088
TRX IV TA 00888880FPT Iveco NEF45SM3Terex TA225-70N50 HzView: TRX IV TA 0088Request a Quote: TRX IV TA 0088
TRX P LS 00888880Perkins 1104A-44TG2Leroy-Somer TAL044 B50 HzView: TRX P LS 0088Request a Quote: TRX P LS 0088
TRX P MC 00888880Perkins 1104A-44TG2Mecc Alte ECP32-2L/450 HzView: TRX P MC 0088Request a Quote: TRX P MC 0088
TRX P ST 00888880Perkins 1104A-44TG2Stamford UCI224G50 HzView: TRX P ST 0088Request a Quote: TRX P ST 0088
TRX P TA 00888880Perkins 1104A-44TG2Terex TA225-70N50 HzView: TRX P TA 0088Request a Quote: TRX P TA 0088
TRX YC TA 00888880Yuchai YC4A110Z-D20Terex TA225-70N50 HzView: TRX YC TA 0088Request a Quote: TRX YC TA 0088

Not sure how much power you need? Let’s calculate it together

Fuel consumption, tank, dimensions and weight

Values are taken from our product data. Dimension, weight and tank columns are for the Canopied (soundproof) version; fields without data are shown as "–".

ModelAt 50% load (L/h)At 75% load (L/h)At 100% load (L/h)Fuel tank (L)Dimensions (L × W × H) (mm)Weight (kg)
TRX CU LS 0066–11.5151252350 × 1000 × 15501,300
TRX CU MC 0066–11.5151252350 × 1000 × 15501,300
TRX CU ST 0066–11.5151252350 × 1000 × 15501,300
TRX CU TA 0066–11.5151252350 × 1000 × 15501,300
TRX IV LS 0066710.213.71252350 × 1000 × 15501,300
TRX IV MC 0066710.213.71252350 × 1000 × 15501,300
TRX IV ST 0066710.213.71252350 × 1000 × 15501,300
TRX IV TA 0066710.213.71252350 × 1000 × 15501,300
TRX P LS 00667.210.413.91012300 × 1000 × 1545973
TRX P MC 00667.210.413.91012300 × 1000 × 1545998
TRX P ST 00667.210.413.91012300 × 1000 × 15451,026
TRX P TA 00667.210.413.91012300 × 1000 × 15451,026
TRX YD TA 00667.69.712.11392600 × 1000 × 15701,033
TRX YC TA 00698.312.416.32202440 × 1000 × 18601,370
TRX BD MC 00727.711151392600 × 1000 × 15701,087
TRX BD ST 00727.711151392600 × 1000 × 15701,119
TRX BD TA 00727.711151392600 × 1000 × 15701,119
TRX P LS 0072811.214.81392600 × 1000 × 15701,194
TRX P MC 0072811.214.81392600 × 1000 × 15701,144
TRX P ST 0072811.214.81392600 × 1000 × 15701,172
TRX P TA 0072811.214.81392600 × 1000 × 15701,172
TRX YD TA 00757.69.912.31252200 × 1000 × 15501,525
TRX SD TA 00767.51114.81252350 × 1000 × 15501,380
TRX KF TA 00778.111.8151252350 × 1000 × 15501,065
TRX QZ TA 00777.410.914.71252350 × 1000 × 15501,450
TRX YC TA 00809.413.417.83002750 × 1100 × 18601,410
TRX IV LS 00828.612.717.11252350 × 1000 × 15501,380
TRX IV MC 00828.612.717.11252350 × 1000 × 15501,380
TRX IV ST 00828.612.717.11252350 × 1000 × 15501,380
TRX IV TA 00828.612.717.11252350 × 1000 × 15501,380
TRX BD MC 00889.113.518.81392600 × 1000 × 15701,137
TRX BD ST 00889.113.518.81392600 × 1000 × 15701,268
TRX BD TA 00889.113.518.81392600 × 1000 × 15701,268
TRX IV LS 00889.615.419.41392600 × 1000 × 15701,244
TRX IV MC 00889.615.419.41392600 × 1000 × 15701,113
TRX IV ST 00889.615.419.41392600 × 1000 × 15701,244
TRX IV TA 00889.615.419.41392600 × 1000 × 15701,244
TRX P LS 00889.71418.71392600 × 1000 × 15701,227
TRX P MC 00889.71418.71392600 × 1000 × 15701,184
TRX P ST 00889.71418.71392600 × 1000 × 15701,315
TRX P TA 00889.71418.71392600 × 1000 × 15701,315
TRX YC TA 00889.914.419.43002750 × 1100 × 18601,560

What can a 75 kVA generator supply?

At a power factor of 0.8, 75 kVA corresponds to about 60 kW of active power. On a 400 V three-phase supply, the full-load current is about 108 A.

Generators in this power range are typically used for:

  • Shops, restaurants and cafés
  • Shared services of apartment buildings (lift, booster pump, lighting)
  • Workshops and small production units
  • Irrigation pumps

These examples are general information; the same rating does not cover the same load at every site. Sizing must be based on the total power of the connected equipment, motor starting currents and how much runs at the same time.

To calculate the required rating from a list of equipment: Power Calculator

What determines the price of a 75 kVA generator

Two generators of the same rating can differ in price depending on the equipment chosen. The main factors are:

  • Engine brand and model
  • Alternator brand and model
  • Enclosure: soundproof canopy or open type
  • Control panel and automatic transfer switch (ATS)
  • Fuel tank capacity
  • Delivery location and transport

A written price quote is prepared once you send us your power requirement and preferred equipment.

Get price and lead timeCall +90 216 634 34 06

Frequently asked questions

How many kW is a 75 kVA generator?

At a power factor of 0.8, 75 kVA equals 60 kW of active power (kW = kVA × 0.8). The models on this page have standby ratings of 52.8–70.4 kW.

How much fuel does a 75 kVA generator use per hour?

According to manufacturer data, the models on this page use 9.7–15.4 litres per hour at 75% load. Consumption varies with load, engine and operating conditions; each model’s values are on its product page.

What does the price of a 75 kVA generator depend on?

The price depends on the engine and alternator brand, the enclosure (canopy or open type), the control panel and ATS, the fuel tank capacity and the delivery location. A written price quote is prepared once you send us your power requirement and preferred equipment.

Request a quote for a 75 kVA generator

Tell us your power requirement, duty (standby or prime) and delivery location, and we will prepare a quote for your project.

Get price and lead time

Chat on WhatsApp

Download