100 kVA (80 kW) Diesel Generator

This page lists 33 diesel generator models with standby ratings of 90–110 kVA (72–88 kW). Ratings listed: 90, 94, 100, 105, and 110 kVA.

Get price and lead timeView models

Terex Diesel canopied diesel generator

Request a quote

Tell us your power requirement, duty (standby or prime) and delivery location, and we will prepare a quote for your project.

Contact us directly

Call +90 216 634 34 06WhatsApp +90 533 582 26 50

Your request has been received. We will contact you as soon as possible.

Could not send. Please try again or call us. You can also reach us directly: WhatsApp +90 533 582 26 50 · info@terexdiesel.com

Too many submissions in a short time. Please try again in a few minutes.

Phone or email (one is enough)

Terms for sales outside Türkiye

  • Dispatch

    Models in stock: 2–3 business days; Perkins, Cummins, Volvo, Kubota, Scania and FPT Iveco: 3–4 weeks after order.

  • Warranty outside Türkiye

    12 months or 1,000 operating hours for all engine brands.

  • Certificates

    ISO 9001 · CE · TSE-HYB

  • Export documents

    A commercial invoice and packing list are prepared; a certificate of origin and any other documents the buyer requires are issued on request.

Export Process and Payment

Key figures

Models
33
Standby power range
90–110 kVA
Engine brands
Perkins, Baudouin, Cummins, FPT Iveco, Kofo, Quartz, SDEC, Yangdong, Yuchai
Fuel consumption (75% load)
10.3–20.2 L/h
Weight with canopy
1,208–1,800 kg
Typical canopy dimensions (L × W × H)
2650 × 1100 × 1750 mm

Figures are calculated from the technical data of the models on this page; per-model values are on each product page.

Models rated 90–110 kVA standby

The table shows each model’s standby and prime ratings, engine and alternator; click a model name for full specifications. Use the compare button in the table to view models side by side.

Models rated 90–110 kVA standby
ModelStandby (kVA)Prime (kVA)EngineAlternatorFrequencyCompareView
TRX CU LS 00909082Cummins 4BTAA3.9G4Leroy-Somer TAL044 B50 HzView: TRX CU LS 0090Request a Quote: TRX CU LS 0090
TRX CU MC 00909082Cummins 4BTAA3.9G4Mecc Alte ECP32-2L/450 HzView: TRX CU MC 0090Request a Quote: TRX CU MC 0090
TRX CU ST 00909082Cummins 4BTAA3.9G4Stamford UCI224G50 HzView: TRX CU ST 0090Request a Quote: TRX CU ST 0090
TRX CU TA 00909082Cummins 4BTAA3.9G4Terex TA225-70N50 HzView: TRX CU TA 0090Request a Quote: TRX CU TA 0090
TRX KF TA 00909081Kofo MN4105ZLDSTerex TA225-70N50 HzView: TRX KF TA 0090Request a Quote: TRX KF TA 0090
TRX QZ TA 00909081Quartz Q4105IZLDTerex TA225-70N50 HzView: TRX QZ TA 0090Request a Quote: TRX QZ TA 0090
TRX IV LS 00949485FPT Iveco NEF45TM1ALeroy-Somer TAL044 D50 HzView: TRX IV LS 0094Request a Quote: TRX IV LS 0094
TRX IV MC 00949485FPT Iveco NEF45TM1AMecc Alte ECP34-2S/450 HzView: TRX IV MC 0094Request a Quote: TRX IV MC 0094
TRX IV ST 00949485FPT Iveco NEF45TM1AStamford UCI274C50 HzView: TRX IV ST 0094Request a Quote: TRX IV ST 0094
TRX IV TA 00949485FPT Iveco NEF45TM1ATerex TA225-80N50 HzView: TRX IV TA 0094Request a Quote: TRX IV TA 0094
TRX SD TA 010010091SDEC SC4H115D2Terex TA225-80N50 HzView: TRX SD TA 0100Request a Quote: TRX SD TA 0100
TRX YD TA 010010087Yangdong Y4110ZLDATerex TA225-80N50 HzView: TRX YD TA 0100Request a Quote: TRX YD TA 0100
TRX QZ TA 010510594.5Quartz Q4105AZLDTerex TA225-80N50 HzView: TRX QZ TA 0105Request a Quote: TRX QZ TA 0105
TRX BD MC 0110110100Baudouin 4M10G6D0/SMecc Alte ECP34-2S/450 HzView: TRX BD MC 0110Request a Quote: TRX BD MC 0110
TRX BD ST 0110110100Baudouin 4M10G6D0/SStamford UCI274C50 HzView: TRX BD ST 0110Request a Quote: TRX BD ST 0110
TRX BD TA 0110110100Baudouin 4M10G6D0/STerex TA225-80N50 HzView: TRX BD TA 0110Request a Quote: TRX BD TA 0110
TRX CU LS 0110110100Cummins 6BTAA5.9G13Leroy-Somer TAL044 D50 HzView: TRX CU LS 0110Request a Quote: TRX CU LS 0110
TRX CU MC 0110110100Cummins 6BTAA5.9G13Mecc Alte ECP34-2S/450 HzView: TRX CU MC 0110Request a Quote: TRX CU MC 0110
TRX CU ST 0110110100Cummins 6BTAA5.9G13Stamford S3L1D-C4150 HzView: TRX CU ST 0110Request a Quote: TRX CU ST 0110
TRX CU TA 0110110100Cummins 6BTAA5.9G13Terex TA225-80N50 HzView: TRX CU TA 0110Request a Quote: TRX CU TA 0110
TRX IV LS 0110110100FPT Iveco NEF45TM2ALeroy-Somer TAL044 D50 HzView: TRX IV LS 0110Request a Quote: TRX IV LS 0110
TRX IV MC 0110110100FPT Iveco NEF45TM2AMecc Alte ECP34-2S/450 HzView: TRX IV MC 0110Request a Quote: TRX IV MC 0110
TRX IV ST 0110110100FPT Iveco NEF45TM2AStamford UCI274C50 HzView: TRX IV ST 0110Request a Quote: TRX IV ST 0110
TRX IV TA 0110110100FPT Iveco NEF45TM2ATerex TA225-80N50 HzView: TRX IV TA 0110Request a Quote: TRX IV TA 0110
TRX KF TA 0110110100Kofo 4RT55-88DTerex TA225-90N50 HzView: TRX KF TA 0110Request a Quote: TRX KF TA 0110
TRX KF TA 0110-6110100Kofo R6105ZDSTerex TA225-90N50 HzView: TRX KF TA 0110-6Request a Quote: TRX KF TA 0110-6
TRX P LS 0110110100Perkins 1104C-44TAG2Leroy-Somer TAL044 D50 HzView: TRX P LS 0110Request a Quote: TRX P LS 0110
TRX P MC 0110110100Perkins 1104C-44TAG2Mecc Alte ECP34-2S/450 HzView: TRX P MC 0110Request a Quote: TRX P MC 0110
TRX P ST 0110110100Perkins 1104C-44TAG2Stamford UCI274C50 HzView: TRX P ST 0110Request a Quote: TRX P ST 0110
TRX P TA 0110110100Perkins 1104C-44TAG2Terex TA225-80N50 HzView: TRX P TA 0110Request a Quote: TRX P TA 0110
TRX QZ TA 0110110100Quartz Q6105AZLDTerex TA225-100N50 HzView: TRX QZ TA 0110Request a Quote: TRX QZ TA 0110
TRX YC TA 0110110100Yuchai YC4A140L-D20Terex TA225-100N50 HzView: TRX YC TA 0110Request a Quote: TRX YC TA 0110
TRX YD TA 0110110100Yangdong Y4GZLDTerex TA225-90N50 HzView: TRX YD TA 0110Request a Quote: TRX YD TA 0110

Not sure how much power you need? Let’s calculate it together

Fuel consumption, tank, dimensions and weight

Values are taken from our product data. Dimension, weight and tank columns are for the Canopied (soundproof) version; fields without data are shown as "–".

ModelAt 50% load (L/h)At 75% load (L/h)At 100% load (L/h)Fuel tank (L)Dimensions (L × W × H) (mm)Weight (kg)
TRX CU LS 0090–15.220.31252350 × 1000 × 15501,380
TRX CU MC 0090–15.220.31252350 × 1000 × 15501,380
TRX CU ST 0090–15.220.31252350 × 1000 × 15501,380
TRX CU TA 0090–15.220.31252350 × 1000 × 15501,380
TRX KF TA 0090710.313.52652650 × 1100 × 17501,255
TRX QZ TA 00908.712.917.41252350 × 1000 × 15501,650
TRX IV LS 00948.214.419.32652650 × 1100 × 17501,530
TRX IV MC 00948.214.419.32652650 × 1100 × 17501,530
TRX IV ST 00948.214.419.32652650 × 1100 × 17501,530
TRX IV TA 00948.214.419.32652650 × 1100 × 17501,530
TRX SD TA 010010.315.220.21252350 × 1000 × 15501,450
TRX YD TA 01007.910.613.51252350 × 1000 × 15501,600
TRX QZ TA 0105–––1252350 × 1000 × 15501,800
TRX BD MC 011010.61621.31392600 × 1000 × 15701,345
TRX BD ST 011010.61621.31392600 × 1000 × 15701,350
TRX BD TA 011010.61621.31392600 × 1000 × 15701,350
TRX CU LS 0110–18.324.62653000 × 1100 × 18501,785
TRX CU MC 0110–18.324.62653000 × 1100 × 18501,785
TRX CU ST 0110–18.324.62653000 × 1100 × 18501,785
TRX CU TA 0110–18.324.62653000 × 1100 × 18501,785
TRX IV LS 01101116.2222723220 × 1100 × 18451,478
TRX IV MC 01101116.2222723220 × 1100 × 18451,491
TRX IV ST 01101116.2222723220 × 1100 × 18451,478
TRX IV TA 01101116.2222723220 × 1100 × 18451,478
TRX KF TA 01101014182652650 × 1100 × 17501,365
TRX KF TA 0110-611.116.622.22653000 × 1100 × 18501,395
TRX P LS 011014.120.226.91392600 × 1000 × 15701,208
TRX P MC 011014.120.226.91392600 × 1000 × 15701,365
TRX P ST 011014.120.226.91392600 × 1000 × 15701,352
TRX P TA 011014.120.226.91392600 × 1000 × 15701,352
TRX QZ TA 0110–––3102980 × 1100 × 20001,715
TRX YC TA 011011.817.223.13102980 × 1100 × 20001,750
TRX YD TA 011014.218.922.11252350 × 1000 × 15501,680

What can a 100 kVA generator supply?

At a power factor of 0.8, 100 kVA corresponds to about 80 kW of active power. On a 400 V three-phase supply, the full-load current is about 144 A.

Generators in this power range are typically used for:

  • Shared services of residential complexes
  • Hotels, schools and commercial buildings
  • Medium-sized workshops and production lines
  • Cranes, welding machines and equipment on construction sites
  • Agricultural irrigation and cold stores

These examples are general information; the same rating does not cover the same load at every site. Sizing must be based on the total power of the connected equipment, motor starting currents and how much runs at the same time.

To calculate the required rating from a list of equipment: Power Calculator

What determines the price of a 100 kVA generator

Two generators of the same rating can differ in price depending on the equipment chosen. The main factors are:

  • Engine brand and model
  • Alternator brand and model
  • Enclosure: soundproof canopy or open type
  • Control panel and automatic transfer switch (ATS)
  • Fuel tank capacity
  • Delivery location and transport

A written price quote is prepared once you send us your power requirement and preferred equipment.

Get price and lead timeCall +90 216 634 34 06

Frequently asked questions

How many kW is a 100 kVA generator?

At a power factor of 0.8, 100 kVA equals 80 kW of active power (kW = kVA × 0.8). The models on this page have standby ratings of 72–88 kW.

How much fuel does a 100 kVA generator use per hour?

According to manufacturer data, the models on this page use 10.3–20.2 litres per hour at 75% load. Consumption varies with load, engine and operating conditions; each model’s values are on its product page.

What does the price of a 100 kVA generator depend on?

The price depends on the engine and alternator brand, the enclosure (canopy or open type), the control panel and ATS, the fuel tank capacity and the delivery location. A written price quote is prepared once you send us your power requirement and preferred equipment.

Request a quote for a 100 kVA generator

Tell us your power requirement, duty (standby or prime) and delivery location, and we will prepare a quote for your project.

Get price and lead time

Chat on WhatsApp