1250 kVA (1000 kW) Diesel Generator

This page lists 20 diesel generator models with standby ratings of 1250–1400 kVA (1000–1120 kW). Ratings listed: 1250, 1375, 1385, and 1400 kVA.

Get price and lead timeView models

Terex Diesel high-output canopied diesel generator

Request a quote

Tell us your power requirement, duty (standby or prime) and delivery location, and we will prepare a quote for your project.

Contact us directly

Call +90 216 634 34 06WhatsApp +90 533 582 26 50

Your request has been received. We will contact you as soon as possible.

Could not send. Please try again or call us. You can also reach us directly: WhatsApp +90 533 582 26 50 · info@terexdiesel.com

Too many submissions in a short time. Please try again in a few minutes.

Phone or email (one is enough)

Terms for sales outside Türkiye

  • Warranty outside Türkiye

    12 months or 1,000 operating hours for all engine brands.

  • Certificates

    ISO 9001 · CE · TSE-HYB

  • Export documents

    A commercial invoice and packing list are prepared; a certificate of origin and any other documents the buyer requires are issued on request.

Export Process and Payment

Key figures

Models
20
Standby power range
1,250–1,400 kVA
Engine brands
Perkins, Baudouin, Cummins, Yuchai
Fuel consumption (75% load)
175–216.3 L/h

Figures are calculated from the technical data of the models on this page; per-model values are on each product page.

Models rated 1250–1400 kVA standby

The table shows each model’s standby and prime ratings, engine and alternator; click a model name for full specifications. Use the compare button in the table to view models side by side.

Models rated 1250–1400 kVA standby
ModelStandby (kVA)Prime (kVA)EngineAlternatorFrequencyCompareView
TRX BD MC 12501,2501,150Baudouin 12M33G1250/5Mecc Alte ECO43-2M/450 HzView: TRX BD MC 1250Request a Quote: TRX BD MC 1250
TRX BD ST 12501,2501,150Baudouin 12M33G1250/5Stamford S6L1D-F450 HzView: TRX BD ST 1250Request a Quote: TRX BD ST 1250
TRX BD TA 12501,2501,150Baudouin 12M33G1250/5Terex TA400-900N50 HzView: TRX BD TA 1250Request a Quote: TRX BD TA 1250
TRX CU ST 12501,2501,137.5Cummins KTA38-G9Stamford HCI634Y50 HzView: TRX CU ST 1250Request a Quote: TRX CU ST 1250
TRX P LS 12501,2501,125Perkins 4008-30TAG3Leroy-Somer LSA 50.2 M650 HzView: TRX P LS 1250Request a Quote: TRX P LS 1250
TRX P MC 12501,2501,125Perkins 4008-30TAG3Mecc Alte ECO43-2M/450 HzView: TRX P MC 1250Request a Quote: TRX P MC 1250
TRX P ST 12501,2501,125Perkins 4008-30TAG3Stamford S6L1D-F450 HzView: TRX P ST 1250Request a Quote: TRX P ST 1250
TRX P TA 12501,2501,125Perkins 4008-30TAG3Terex TA400-900N50 HzView: TRX P TA 1250Request a Quote: TRX P TA 1250
TRX CU LS 13751,3751,250Cummins KTA50G4Leroy-Somer LSA 50.2 M650 HzView: TRX CU LS 1375Request a Quote: TRX CU LS 1375
TRX CU MC 13751,3751,250Cummins KTA50G4Mecc Alte ECO43-2L/450 HzView: TRX CU MC 1375Request a Quote: TRX CU MC 1375
TRX CU ST 13751,3751,250Cummins KTA50G4Stamford HCI634Y50 HzView: TRX CU ST 1375Request a Quote: TRX CU ST 1375
TRX CU TA 13751,3751,250Cummins KTA50G4Terex TA400-1100N50 HzView: TRX CU TA 1375Request a Quote: TRX CU TA 1375
TRX YC TA 13751,3751,250Yuchai YC12VTD1680-D30Terex TA400-1100N50 HzView: TRX YC TA 1375Request a Quote: TRX YC TA 1375
TRX P LS 13851,3851,250Perkins 4012-46TWG2ALeroy-Somer LSA 50.2 M650 HzView: TRX P LS 1385Request a Quote: TRX P LS 1385
TRX P MC 13851,3851,250Perkins 4012-46TWG2AMecc Alte ECO43-2L/450 HzView: TRX P MC 1385Request a Quote: TRX P MC 1385
TRX P ST 13851,3851,250Perkins 4012-46TWG2AStamford S6L1D-H450 HzView: TRX P ST 1385Request a Quote: TRX P ST 1385
TRX P TA 13851,3851,250Perkins 4012-46TWG2ATerex TA400-1100N50 HzView: TRX P TA 1385Request a Quote: TRX P TA 1385
TRX BD MC 14001,4001,250Baudouin 12M33G1400/5Mecc Alte ECO43-2L/450 HzView: TRX BD MC 1400Request a Quote: TRX BD MC 1400
TRX BD ST 14001,4001,250Baudouin 12M33G1400/5Stamford S6L1D-H450 HzView: TRX BD ST 1400Request a Quote: TRX BD ST 1400
TRX BD TA 14001,4001,250Baudouin 12M33G1400/5Terex TA400-1100N50 HzView: TRX BD TA 1400Request a Quote: TRX BD TA 1400

Not sure how much power you need? Let’s calculate it together

Fuel consumption, tank, dimensions and weight

Values are taken from our product data. Dimension, weight and tank columns are for the Open type version; fields without data are shown as "–".

ModelAt 50% load (L/h)At 75% load (L/h)At 100% load (L/h)Fuel tank (L)Dimensions (L × W × H) (mm)Weight (kg)
TRX BD MC 1250119.5175236.22,3955810 × 2100 × 29278,743
TRX BD ST 1250119.5175236.22,3955810 × 2100 × 29278,914
TRX BD TA 1250119.5175236.22,3955810 × 2100 × 29278,914
TRX CU ST 12501371962561,3504700 × 2100 × 32008,694
TRX P LS 12501201882442,1384900 × 2200 × 25708,335
TRX P MC 12501201882442,1384900 × 2200 × 25708,215
TRX P ST 12501201882442,1384900 × 2200 × 25708,390
TRX P TA 12501201882442,1384900 × 2200 × 25708,390
TRX CU LS 13751542062742,1004900 × 2500 × 320010,000
TRX CU MC 13751542062742,1004900 × 2500 × 320010,000
TRX CU ST 13751542062742,1005000 × 2250 × 272010,895
TRX CU TA 13751542062742,1004900 × 2500 × 320010,000
TRX YC TA 1375143.1216.3281.99904535 × 2218 × 25348,700
TRX P LS 13851411962582,3385150 × 2300 × 27338,971
TRX P MC 13851411962582,3385150 × 2300 × 27339,181
TRX P ST 13851411962582,3385150 × 2300 × 27339,241
TRX P TA 13851411962582,3385150 × 2300 × 27339,241
TRX BD MC 1400129.2190.7258.62,3955810 × 2100 × 29279,743
TRX BD ST 1400129.2190.7258.62,3955810 × 2100 × 29279,803
TRX BD TA 1400129.2190.7258.62,3955810 × 2100 × 29279,803

What can a 1250 kVA generator supply?

At a power factor of 0.8, 1250 kVA corresponds to about 1,000 kW of active power. On a 400 V three-phase supply, the full-load current is about 1,804 A.

Generators in this power range are typically used for:

  • Large industrial plants
  • Hospital campuses and data centres
  • Mining and energy sites
  • Multi-generator systems running in parallel

These examples are general information; the same rating does not cover the same load at every site. Sizing must be based on the total power of the connected equipment, motor starting currents and how much runs at the same time.

To calculate the required rating from a list of equipment: Power Calculator

What determines the price of a 1250 kVA generator

Two generators of the same rating can differ in price depending on the equipment chosen. The main factors are:

  • Engine brand and model
  • Alternator brand and model
  • Enclosure: container or open type
  • Control panel and automatic transfer switch (ATS)
  • Fuel tank capacity
  • Delivery location and transport

A written price quote is prepared once you send us your power requirement and preferred equipment.

Get price and lead timeCall +90 216 634 34 06

One set or several sets in parallel?

In this power class the load can be supplied by one set or by several sets running in parallel through a synchronization panel. In a parallel system one set can be stopped for maintenance while the others carry the load, and at low load one set can be shut down. The choice depends on the load profile, the redundancy required and site conditions, and is made at the quotation stage.

Standby power is for backup during mains failures. Where there is no grid, or the set will run for long periods, size the set on its prime rating.

Canopy sets go up to 1,100 kVA; sets above 1,100 kVA are supplied in a container: Containerised Generators

Frequently asked questions

How many kW is a 1250 kVA generator?

At a power factor of 0.8, 1250 kVA equals 1000 kW of active power (kW = kVA × 0.8). The models on this page have standby ratings of 1000–1120 kW.

How much fuel does a 1250 kVA generator use per hour?

According to manufacturer data, the models on this page use 175–216.3 litres per hour at 75% load. Consumption varies with load, engine and operating conditions; each model’s values are on its product page.

What does the price of a 1250 kVA generator depend on?

The price depends on the engine and alternator brand, the enclosure (container or open type), the control panel and ATS, the fuel tank capacity and the delivery location. A written price quote is prepared once you send us your power requirement and preferred equipment.

Request a quote for a 1250 kVA generator

Tell us your power requirement, duty (standby or prime) and delivery location, and we will prepare a quote for your project.

Get price and lead time

Chat on WhatsApp

Download