650 kVA (520 kW) Diesel Generator
This page lists 29 diesel generator models with standby ratings of 600–700 kVA (480–560 kW). Ratings listed: 600, 615, 625, 630, 660, 688, and 700 kVA.

Request a quote
Tell us your power requirement, duty (standby or prime) and delivery location, and we will prepare a quote for your project.
Contact us directly
Terms for sales outside Türkiye
- Warranty outside Türkiye
12 months or 1,000 operating hours for all engine brands.
- Certificates
ISO 9001 · CE · TSE-HYB
- Export documents
A commercial invoice and packing list are prepared; a certificate of origin and any other documents the buyer requires are issued on request.
Key figures
- Models
- 29
- Standby power range
- 600–700 kVA
- Engine brands
- Perkins, Baudouin, Cummins, FPT Iveco, Scania, SDEC, Volvo Penta, Yuchai
- Fuel consumption (75% load)
- 82–107 L/h
- Weight with canopy
- 4,144–7,882 kg
- Typical canopy dimensions (L × W × H)
- 4000 × 1816 × 2925 mm
Figures are calculated from the technical data of the models on this page; per-model values are on each product page.
Models rated 600–700 kVA standby
The table shows each model’s standby and prime ratings, engine and alternator; click a model name for full specifications. Use the compare button in the table to view models side by side.
Not sure how much power you need? Let’s calculate it together
Fuel consumption, tank, dimensions and weight
Values are taken from our product data. Dimension, weight and tank columns are for the Canopied (soundproof) version; fields without data are shown as "–".
| Model | At 50% load (L/h) | At 75% load (L/h) | At 100% load (L/h) | Fuel tank (L) | Dimensions (L × W × H) (mm) | Weight (kg) |
|---|---|---|---|---|---|---|
| TRX SD TA 0600 | 60.7 | 85.9 | 113.8 | 1,860 | 4500 × 2200 × 3200 | 7,632 |
| TRX SC MC 0615 | 56 | 82 | 110 | 1,860 | 4500 × 2200 × 3200 | 7,632 |
| TRX SC ST 0615 | 56 | 82 | 110 | 1,860 | 4500 × 2200 × 3200 | 7,632 |
| TRX SC TA 0615 | 56 | 82 | 110 | 1,860 | 4500 × 2200 × 3200 | 7,632 |
| TRX YC TA 0625 | 71.6 | 107 | 137 | 1,410 | 5000 × 2100 × 3050 | 6,200 |
| TRX VL MC 0630 | 58.4 | 87.6 | 118.6 | 1,136 | 4685 × 1918 × 2920 | 4,741 |
| TRX VL ST 0630 | 58.4 | 87.6 | 118.6 | 1,136 | 4685 × 1918 × 2920 | 4,826 |
| TRX VL TA 0630 | 58.4 | 87.6 | 118.6 | 1,136 | 4685 × 1918 × 2920 | 4,826 |
| TRX BD MC 0660 | 64.7 | 95.4 | 124.2 | 1,035 | 3700 × 1718 × 2887 | 4,835 |
| TRX BD ST 0660 | 64.7 | 95.4 | 124.2 | 1,035 | 3700 × 1718 × 2887 | 5,062 |
| TRX BD TA 0660 | 64.7 | 95.4 | 124.2 | 1,035 | 3700 × 1718 × 2887 | 5,062 |
| TRX IV LS 0660 | 57 | 85 | 115 | 846 | 3750 × 1400 × 2646 | 4,236 |
| TRX IV MC 0660 | 57 | 85 | 115 | 846 | 3750 × 1400 × 2646 | 4,144 |
| TRX IV ST 0660 | 57 | 85 | 115 | 846 | 3750 × 1400 × 2646 | 4,236 |
| TRX IV TA 0660 | 57 | 85 | 115 | 846 | 3750 × 1400 × 2646 | 4,236 |
| TRX P LS 0660 | 61 | 90 | 123 | 1,086 | 4000 × 1816 × 2925 | 4,884 |
| TRX P MC 0660 | 61 | 90 | 123 | 1,086 | 4000 × 1816 × 2925 | 5,053 |
| TRX P ST 0660 | 61 | 90 | 123 | 1,086 | 4000 × 1816 × 2925 | 5,280 |
| TRX P TA 0660 | 61 | 90 | 123 | 1,086 | 4000 × 1816 × 2925 | 5,280 |
| TRX SC MC 0660 | 56 | 91 | 121.6 | 1,860 | 4500 × 2200 × 3200 | 7,882 |
| TRX SC ST 0660 | 56 | 91 | 121.6 | 1,860 | 4500 × 2200 × 3200 | 7,882 |
| TRX SC TA 0660 | 56 | 91 | 121.6 | 1,860 | 4500 × 2200 × 3200 | 7,882 |
| TRX SD TA 0660 | 66.3 | 95.3 | 126 | 1,263 | 4200 × 1816 × 2806 | 5,341 |
| TRX YC TA 0688 | 72 | 104.4 | 144.4 | 1,410 | 5000 × 2100 × 3050 | 6,500 |
| TRX CU ST 0700 | – | – | – | 1,100 | 4388 × 1700 × 3650 | 6,609 |
| TRX P LS 0700 | 68 | 97 | 132 | 1,086 | 4000 × 1816 × 2925 | 5,278 |
| TRX P MC 0700 | 68 | 97 | 132 | 1,086 | 4000 × 1816 × 2925 | 5,442 |
| TRX P ST 0700 | 68 | 97 | 132 | 1,086 | 4000 × 1816 × 2925 | 5,591 |
| TRX P TA 0700 | 68 | 97 | 132 | 1,086 | 4000 × 1816 × 2925 | 5,591 |
What can a 650 kVA generator supply?
At a power factor of 0.8, 650 kVA corresponds to about 520 kW of active power. On a 400 V three-phase supply, the full-load current is about 938 A.
Generators in this power range are typically used for:
- Factories and production plants
- Hospitals, shopping centres and large commercial buildings
- Server rooms and telecom centres
- Large construction sites and infrastructure projects
These examples are general information; the same rating does not cover the same load at every site. Sizing must be based on the total power of the connected equipment, motor starting currents and how much runs at the same time.
To calculate the required rating from a list of equipment: Power Calculator
What determines the price of a 650 kVA generator
Two generators of the same rating can differ in price depending on the equipment chosen. The main factors are:
- Engine brand and model
- Alternator brand and model
- Enclosure: soundproof canopy or open type
- Control panel and automatic transfer switch (ATS)
- Fuel tank capacity
- Delivery location and transport
A written price quote is prepared once you send us your power requirement and preferred equipment.
Frequently asked questions
How many kW is a 650 kVA generator?
At a power factor of 0.8, 650 kVA equals 520 kW of active power (kW = kVA × 0.8). The models on this page have standby ratings of 480–560 kW.
How much fuel does a 650 kVA generator use per hour?
According to manufacturer data, the models on this page use 82–107 litres per hour at 75% load. Consumption varies with load, engine and operating conditions; each model’s values are on its product page.
What does the price of a 650 kVA generator depend on?
The price depends on the engine and alternator brand, the enclosure (canopy or open type), the control panel and ATS, the fuel tank capacity and the delivery location. A written price quote is prepared once you send us your power requirement and preferred equipment.
Request a quote for a 650 kVA generator
Tell us your power requirement, duty (standby or prime) and delivery location, and we will prepare a quote for your project.