150 kVA (120 kW) Diesel Generator

This page lists 46 diesel generator models with standby ratings of 125–170 kVA (100–136 kW). Ratings listed: 125, 132, 135, 137, 140, 150, 155, 165, and 170 kVA.

Get price and lead timeView models

Terex Diesel canopied diesel generator

Request a quote

Tell us your power requirement, duty (standby or prime) and delivery location, and we will prepare a quote for your project.

Contact us directly

Call +90 216 634 34 06WhatsApp +90 533 582 26 50

Your request has been received. We will contact you as soon as possible.

Could not send. Please try again or call us. You can also reach us directly: WhatsApp +90 533 582 26 50 · info@terexdiesel.com

Too many submissions in a short time. Please try again in a few minutes.

Phone or email (one is enough)

Terms for sales outside Türkiye

  • Dispatch

    Models in stock: 2–3 business days; Perkins, Cummins, Volvo, Kubota, Scania and FPT Iveco: 3–4 weeks after order.

  • Warranty outside Türkiye

    12 months or 1,000 operating hours for all engine brands.

  • Certificates

    ISO 9001 · CE · TSE-HYB

  • Export documents

    A commercial invoice and packing list are prepared; a certificate of origin and any other documents the buyer requires are issued on request.

Export Process and Payment

Key figures

Models
46
Standby power range
125–170 kVA
Engine brands
Perkins, Baudouin, Cummins, FPT Iveco, Kofo, Quartz, SDEC, Yuchai
Fuel consumption (75% load)
16.7–29.9 L/h
Weight with canopy
1,360–2,650 kg
Typical canopy dimensions (L × W × H)
3000 × 1100 × 1850 mm

Figures are calculated from the technical data of the models on this page; per-model values are on each product page.

Models rated 125–170 kVA standby

The table shows each model’s standby and prime ratings, engine and alternator; click a model name for full specifications. Use the compare button in the table to view models side by side.

Models rated 125–170 kVA standby
ModelStandby (kVA)Prime (kVA)EngineAlternatorFrequencyCompareView
TRX KF TA 0125125113Kofo R6105ZLDSTerex TA225-100N50 HzView: TRX KF TA 0125Request a Quote: TRX KF TA 0125
TRX QZ TA 0125125112.5Quartz Q6105AZLDTerex TA225-100N50 HzView: TRX QZ TA 0125Request a Quote: TRX QZ TA 0125
TRX IV LS 0132132120FPT Iveco NEF45TM3Leroy-Somer TAL044 H50 HzView: TRX IV LS 0132Request a Quote: TRX IV LS 0132
TRX IV MC 0132132120FPT Iveco NEF45TM3Mecc Alte ECP34-2M/450 HzView: TRX IV MC 0132Request a Quote: TRX IV MC 0132
TRX IV ST 0132132120FPT Iveco NEF45TM3Stamford UCI274E50 HzView: TRX IV ST 0132Request a Quote: TRX IV ST 0132
TRX IV TA 0132132120FPT Iveco NEF45TM3Terex TA225-120N50 HzView: TRX IV TA 0132Request a Quote: TRX IV TA 0132
TRX CU LS 0135135125Cummins 6BTAA5.9G13Leroy-Somer TAL044 H50 HzView: TRX CU LS 0135Request a Quote: TRX CU LS 0135
TRX CU MC 0135135125Cummins 6BTAA5.9G13Mecc Alte ECP34-2M/450 HzView: TRX CU MC 0135Request a Quote: TRX CU MC 0135
TRX CU ST 0135135125Cummins 6BTAA5.9G13Stamford S3L1D-D4150 HzView: TRX CU ST 0135Request a Quote: TRX CU ST 0135
TRX CU TA 0135135125Cummins 6BTAA5.9G13Terex TA225-120N50 HzView: TRX CU TA 0135Request a Quote: TRX CU TA 0135
TRX SD TA 0135135123SDEC SC4H160D2Terex TA225-120N50 HzView: TRX SD TA 0135Request a Quote: TRX SD TA 0135
TRX YC TA 0137137125Yuchai YC4A180L-D20Terex TA225-120N50 HzView: TRX YC TA 0137Request a Quote: TRX YC TA 0137
TRX IV LS 0140140125FPT Iveco NEF67SM1Leroy-Somer TAL044 H50 HzView: TRX IV LS 0140Request a Quote: TRX IV LS 0140
TRX IV MC 0140140125FPT Iveco NEF67SM1Mecc Alte ECP34-2M/450 HzView: TRX IV MC 0140Request a Quote: TRX IV MC 0140
TRX IV ST 0140140125FPT Iveco NEF67SM1Stamford UCI274E50 HzView: TRX IV ST 0140Request a Quote: TRX IV ST 0140
TRX IV TA 0140140125FPT Iveco NEF67SM1Terex TA225-120N50 HzView: TRX IV TA 0140Request a Quote: TRX IV TA 0140
TRX BD MC 0150150135Baudouin 6M11G2D0/SMecc Alte ECP34-2M/450 HzView: TRX BD MC 0150Request a Quote: TRX BD MC 0150
TRX BD ST 0150150135Baudouin 6M11G2D0/SStamford UCI274E50 HzView: TRX BD ST 0150Request a Quote: TRX BD ST 0150
TRX BD TA 0150150135Baudouin 6M11G2D0/STerex TA225-120N50 HzView: TRX BD TA 0150Request a Quote: TRX BD TA 0150
TRX CU LS 0150150140Cummins QSB5.9-G1Leroy-Somer TAL044 H50 HzView: TRX CU LS 0150Request a Quote: TRX CU LS 0150
TRX CU MC 0150150140Cummins QSB5.9-G1Mecc Alte ECP34-2M/450 HzView: TRX CU MC 0150Request a Quote: TRX CU MC 0150
TRX CU ST 0150150140Cummins QSB5.9-G1Stamford UCI274F50 HzView: TRX CU ST 0150Request a Quote: TRX CU ST 0150
TRX CU TA 0150150140Cummins QSB5.9-G1Terex TA225-120N50 HzView: TRX CU TA 0150Request a Quote: TRX CU TA 0150
TRX IV LS 0150150135FPT Iveco NEF67TM2ALeroy-Somer TAL044 H50 HzView: TRX IV LS 0150Request a Quote: TRX IV LS 0150
TRX IV MC 0150150135FPT Iveco NEF67TM2AMecc Alte ECP34-2M/450 HzView: TRX IV MC 0150Request a Quote: TRX IV MC 0150
TRX IV ST 0150150135FPT Iveco NEF67TM2AStamford UCI274E50 HzView: TRX IV ST 0150Request a Quote: TRX IV ST 0150
TRX IV TA 0150150135FPT Iveco NEF67TM2ATerex TA225-120N50 HzView: TRX IV TA 0150Request a Quote: TRX IV TA 0150
TRX KF TA 0150150135Kofo R6105AZLDSTerex TA225-120N50 HzView: TRX KF TA 0150Request a Quote: TRX KF TA 0150
TRX P LS 0150150135Perkins 1106A-70TG1Leroy-Somer TAL044 H50 HzView: TRX P LS 0150Request a Quote: TRX P LS 0150
TRX P MC 0150150135Perkins 1106A-70TG1Mecc Alte ECP34-2M/450 HzView: TRX P MC 0150Request a Quote: TRX P MC 0150
TRX P ST 0150150135Perkins 1106A-70TG1Stamford UCI274E50 HzView: TRX P ST 0150Request a Quote: TRX P ST 0150
TRX P TA 0150150135Perkins 1106A-70TG1Terex TA225-120N50 HzView: TRX P TA 0150Request a Quote: TRX P TA 0150
TRX SD TA 0150150136SDEC SC4H180D2Terex TA225-120N50 HzView: TRX SD TA 0150Request a Quote: TRX SD TA 0150
TRX QZ TA 0155155139.5Quartz Q6105AZLDTerex TA225-120N50 HzView: TRX QZ TA 0155Request a Quote: TRX QZ TA 0155
TRX BD MC 0165165150Baudouin 6M11G4D0/SMecc Alte ECP34-2L/450 HzView: TRX BD MC 0165Request a Quote: TRX BD MC 0165
TRX BD ST 0165165150Baudouin 6M11G4D0/SStamford UCI274F50 HzView: TRX BD ST 0165Request a Quote: TRX BD ST 0165
TRX BD TA 0165165150Baudouin 6M11G4D0/STerex TA280-150N50 HzView: TRX BD TA 0165Request a Quote: TRX BD TA 0165
TRX P LS 0165165150Perkins 1106A-70TAG2Leroy-Somer TAL044 J50 HzView: TRX P LS 0165Request a Quote: TRX P LS 0165
TRX P MC 0165165150Perkins 1106A-70TAG2Mecc Alte ECP34-2L/450 HzView: TRX P MC 0165Request a Quote: TRX P MC 0165
TRX P ST 0165165150Perkins 1106A-70TAG2Stamford UCI274F50 HzView: TRX P ST 0165Request a Quote: TRX P ST 0165
TRX P TA 0165165150Perkins 1106A-70TAG2Terex TA280-150N50 HzView: TRX P TA 0165Request a Quote: TRX P TA 0165
TRX YC TA 0165165150Yuchai YC6B205L-D20Terex TA280-150N50 HzView: TRX YC TA 0165Request a Quote: TRX YC TA 0165
TRX CU LS 0170170160Cummins QSB5.9-G2Leroy-Somer TAL044 J50 HzView: TRX CU LS 0170Request a Quote: TRX CU LS 0170
TRX CU MC 0170170160Cummins QSB5.9-G2Mecc Alte ECP34-2L/450 HzView: TRX CU MC 0170Request a Quote: TRX CU MC 0170
TRX CU ST 0170170160Cummins QSB5.9-G2Stamford UCI274G50 HzView: TRX CU ST 0170Request a Quote: TRX CU ST 0170
TRX CU TA 0170170160Cummins QSB5.9-G2Terex TA280-150N50 HzView: TRX CU TA 0170Request a Quote: TRX CU TA 0170

Not sure how much power you need? Let’s calculate it together

Fuel consumption, tank, dimensions and weight

Values are taken from our product data. Dimension, weight and tank columns are for the Canopied (soundproof) version; fields without data are shown as "–".

ModelAt 50% load (L/h)At 75% load (L/h)At 100% load (L/h)Fuel tank (L)Dimensions (L × W × H) (mm)Weight (kg)
TRX KF TA 012512.819.225.62653000 × 1100 × 18501,360
TRX QZ TA 0125–––2653000 × 1100 × 18501,785
TRX IV LS 013214.421.627.62723220 × 1100 × 18451,639
TRX IV MC 013214.421.627.62723220 × 1100 × 18451,577
TRX IV ST 013214.421.627.62723220 × 1100 × 18451,639
TRX IV TA 013214.421.627.62723220 × 1100 × 18451,639
TRX CU LS 0135–22.530.32653000 × 1100 × 18502,135
TRX CU MC 0135–22.530.32653000 × 1100 × 18502,135
TRX CU ST 0135–22.530.32653000 × 1100 × 18502,135
TRX CU TA 0135–22.530.32653000 × 1100 × 18502,135
TRX SD TA 013512.816.7252723220 × 1100 × 18451,514
TRX YC TA 013714.521.629.93102980 × 1100 × 20001,868
TRX IV LS 0140–––2653000 × 1100 × 18502,135
TRX IV MC 0140–––2653000 × 1100 × 18502,135
TRX IV ST 0140–––2653000 × 1100 × 18502,135
TRX IV TA 0140–––2653000 × 1100 × 18502,135
TRX BD MC 015015.92330.22723220 × 1100 × 18451,795
TRX BD ST 015015.92330.22723220 × 1100 × 18451,857
TRX BD TA 015015.92330.22723220 × 1100 × 18451,857
TRX CU LS 0150–25.931.92653000 × 1100 × 18502,450
TRX CU MC 0150–25.931.92653000 × 1100 × 18502,450
TRX CU ST 0150–25.931.92653000 × 1100 × 18502,450
TRX CU TA 0150–25.931.92653000 × 1100 × 18502,450
TRX IV LS 0150–––2653000 × 1100 × 18502,450
TRX IV MC 0150–––2653000 × 1100 × 18502,450
TRX IV ST 0150–––2653000 × 1100 × 18502,450
TRX IV TA 0150–––2653000 × 1100 × 18502,450
TRX KF TA 015015.523.2312653000 × 1100 × 18501,380
TRX P LS 015015.922.730.32723220 × 1100 × 18451,717
TRX P MC 015015.922.730.32723220 × 1100 × 18451,779
TRX P ST 015015.922.730.32723220 × 1100 × 18451,822
TRX P TA 015015.922.730.32723220 × 1100 × 18451,822
TRX SD TA 015014.421.428.62723220 × 1100 × 18451,514
TRX QZ TA 0155–––2653000 × 1100 × 18502,135
TRX BD MC 016516.724.632.62723220 × 1100 × 18451,760
TRX BD ST 016516.724.632.62723220 × 1100 × 18451,870
TRX BD TA 016516.724.632.62723220 × 1100 × 18451,870
TRX P LS 016516.424.733.42723220 × 1100 × 18451,747
TRX P MC 016516.424.733.42723220 × 1100 × 18451,789
TRX P ST 016516.424.733.42723220 × 1100 × 18451,879
TRX P TA 016516.424.733.42723220 × 1100 × 18451,879
TRX YC TA 016517.225.534.93203200 × 1100 × 20002,010
TRX CU LS 01702129.9362653000 × 1100 × 18502,650
TRX CU MC 01702129.9362653000 × 1100 × 18502,650
TRX CU ST 01702129.9362653000 × 1100 × 18502,650
TRX CU TA 01702129.9362653000 × 1100 × 18502,650

What can a 150 kVA generator supply?

At a power factor of 0.8, 150 kVA corresponds to about 120 kW of active power. On a 400 V three-phase supply, the full-load current is about 217 A.

Generators in this power range are typically used for:

  • Shared services of residential complexes
  • Hotels, schools and commercial buildings
  • Medium-sized workshops and production lines
  • Cranes, welding machines and equipment on construction sites
  • Agricultural irrigation and cold stores

These examples are general information; the same rating does not cover the same load at every site. Sizing must be based on the total power of the connected equipment, motor starting currents and how much runs at the same time.

To calculate the required rating from a list of equipment: Power Calculator

What determines the price of a 150 kVA generator

Two generators of the same rating can differ in price depending on the equipment chosen. The main factors are:

  • Engine brand and model
  • Alternator brand and model
  • Enclosure: soundproof canopy or open type
  • Control panel and automatic transfer switch (ATS)
  • Fuel tank capacity
  • Delivery location and transport

A written price quote is prepared once you send us your power requirement and preferred equipment.

Get price and lead timeCall +90 216 634 34 06

Frequently asked questions

How many kW is a 150 kVA generator?

At a power factor of 0.8, 150 kVA equals 120 kW of active power (kW = kVA × 0.8). The models on this page have standby ratings of 100–136 kW.

How much fuel does a 150 kVA generator use per hour?

According to manufacturer data, the models on this page use 16.7–29.9 litres per hour at 75% load. Consumption varies with load, engine and operating conditions; each model’s values are on its product page.

What does the price of a 150 kVA generator depend on?

The price depends on the engine and alternator brand, the enclosure (canopy or open type), the control panel and ATS, the fuel tank capacity and the delivery location. A written price quote is prepared once you send us your power requirement and preferred equipment.

Request a quote for a 150 kVA generator

Tell us your power requirement, duty (standby or prime) and delivery location, and we will prepare a quote for your project.

Get price and lead time

Chat on WhatsApp

Download