500 kVA (400 kW) Diesel Generator
This page lists 67 diesel generator models with standby ratings of 440–550 kVA (352–440 kW). Ratings listed: 440, 450, 460, 500, 520, and 550 kVA.

Request a quote
Tell us your power requirement, duty (standby or prime) and delivery location, and we will prepare a quote for your project.
Contact us directly
Terms for sales outside Türkiye
- Warranty outside Türkiye
12 months or 1,000 operating hours for all engine brands.
- Certificates
ISO 9001 · CE · TSE-HYB
- Export documents
A commercial invoice and packing list are prepared; a certificate of origin and any other documents the buyer requires are issued on request.
Key figures
- Models
- 67
- Standby power range
- 440–550 kVA
- Engine brands
- Perkins, Baudouin, Cummins, FPT Iveco, Kofo, Scania, SDEC, Volvo Penta, Yuchai
- Fuel consumption (75% load)
- 50–80.6 L/h
- Weight with canopy
- 2,770–5,775 kg
- Typical canopy dimensions (L × W × H)
- 4050 × 1600 × 2615 mm
Figures are calculated from the technical data of the models on this page; per-model values are on each product page.
Models rated 440–550 kVA standby
The table shows each model’s standby and prime ratings, engine and alternator; click a model name for full specifications. Use the compare button in the table to view models side by side.
Not sure how much power you need? Let’s calculate it together
Fuel consumption, tank, dimensions and weight
Values are taken from our product data. Dimension, weight and tank columns are for the Canopied (soundproof) version; fields without data are shown as "–".
| Model | At 50% load (L/h) | At 75% load (L/h) | At 100% load (L/h) | Fuel tank (L) | Dimensions (L × W × H) (mm) | Weight (kg) |
|---|---|---|---|---|---|---|
| TRX BD MC 0440 | 43.2 | 63.5 | 85.5 | 846 | 3750 × 1400 × 2646 | 3,422 |
| TRX BD ST 0440 | 43.2 | 63.5 | 85.5 | 846 | 3750 × 1400 × 2646 | 3,533 |
| TRX BD TA 0440 | 43.2 | 63.5 | 85.5 | 846 | 3750 × 1400 × 2646 | 3,533 |
| TRX IV LS 0440 | 42.8 | 70.4 | 85.8 | 846 | 3750 × 1400 × 2646 | 3,471 |
| TRX IV MC 0440 | 42.8 | 70.4 | 85.8 | 846 | 3750 × 1400 × 2646 | 3,330 |
| TRX IV ST 0440 | 42.8 | 70.4 | 85.8 | 846 | 3750 × 1400 × 2646 | 3,471 |
| TRX IV TA 0440 | 42.8 | 70.4 | 85.8 | 846 | 3750 × 1400 × 2646 | 3,471 |
| TRX SD TA 0440 | 41.1 | 59.8 | 81.2 | 846 | 3750 × 1400 × 2646 | 3,593 |
| TRX VL MC 0440 | 41.7 | 61.3 | 80.9 | 979 | 4089 × 1420 × 2566 | 3,764 |
| TRX VL ST 0440 | 41.7 | 61.3 | 80.9 | 979 | 4089 × 1420 × 2566 | 3,905 |
| TRX VL TA 0440 | 41.7 | 61.3 | 80.9 | 979 | 4089 × 1420 × 2566 | 3,905 |
| TRX CU LS 0450 | – | – | – | 1,370 | – | 5,225 |
| TRX CU MC 0450 | – | – | – | 1,370 | – | 5,225 |
| TRX CU ST 0450 | – | – | – | 1,370 | – | 5,225 |
| TRX CU TA 0450 | – | – | – | 1,370 | – | 5,225 |
| TRX P LS 0450 | 42 | 62 | 81 | 819 | 4050 × 1600 × 2615 | 3,772 |
| TRX P MC 0450 | 42 | 62 | 81 | 819 | 4050 × 1600 × 2615 | 3,845 |
| TRX P ST 0450 | 42 | 62 | 81 | 819 | 4050 × 1600 × 2615 | 3,986 |
| TRX P TA 0450 | 42 | 62 | 81 | 819 | 4050 × 1600 × 2615 | 3,986 |
| TRX SC MC 0450 | 40 | 59 | 79.5 | 1,370 | – | 5,225 |
| TRX SC ST 0450 | 40 | 59 | 79.5 | 1,370 | – | 5,225 |
| TRX SC TA 0450 | 40 | 59 | 79.5 | 1,370 | – | 5,225 |
| TRX KF TA 0460 | 35 | 52 | 70 | 810 | 3750 × 1500 × 2500 | 2,770 |
| TRX BD MC 0500 | 46.4 | 69.6 | 95.9 | 846 | 3750 × 1400 × 2646 | 3,750 |
| TRX BD ST 0500 | 46.4 | 69.6 | 95.9 | 846 | 3750 × 1400 × 2646 | 3,523 |
| TRX BD TA 0500 | 46.4 | 69.6 | 95.9 | 846 | 3750 × 1400 × 2646 | 3,523 |
| TRX CU ST 0500 | 49 | 70 | 93 | 810 | 4640 × 1600 × 2750 | 4,992 |
| TRX IV LS 0500 | 51.8 | 72.5 | 89.9 | 1,370 | – | 5,225 |
| TRX IV MC 0500 | 51.8 | 72.5 | 89.9 | 1,370 | – | 5,225 |
| TRX IV ST 0500 | 51.8 | 72.5 | 89.9 | 1,370 | – | 5,225 |
| TRX IV TA 0500 | 51.8 | 72.5 | 89.9 | 1,370 | – | 5,225 |
| TRX P LS 0500 | 50 | 72 | 95 | 819 | 4050 × 1600 × 2615 | 4,084 |
| TRX P MC 0500 | 50 | 72 | 95 | 819 | 4050 × 1600 × 2615 | 4,084 |
| TRX P ST 0500 | 50 | 72 | 95 | 819 | 4050 × 1600 × 2615 | 4,141 |
| TRX P TA 0500 | 50 | 72 | 95 | 819 | 4050 × 1600 × 2615 | 4,141 |
| TRX SC MC 0500 | 44 | 65.8 | 89.2 | 1,370 | – | 5,500 |
| TRX SC ST 0500 | 44 | 65.8 | 89.2 | 1,370 | – | 5,500 |
| TRX SC TA 0500 | 44 | 65.8 | 89.2 | 1,370 | – | 5,500 |
| TRX VL MC 0500 | 45.5 | 67.2 | 89.1 | 979 | 4089 × 1420 × 2566 | 3,848 |
| TRX VL ST 0500 | 45.5 | 67.2 | 89.1 | 979 | 4089 × 1420 × 2566 | 3,905 |
| TRX VL TA 0500 | 45.5 | 67.2 | 89.1 | 979 | 4089 × 1420 × 2566 | 3,905 |
| TRX YC TA 0500 | 50.5 | 72.7 | 98.2 | 810 | 4640 × 1600 × 2750 | 4,555 |
| TRX SD TA 0520 | 53.6 | 75.8 | 100.4 | 1,370 | – | 5,500 |
| TRX BD MC 0550 | 51 | 75.3 | 109.5 | 1,370 | – | 5,775 |
| TRX BD ST 0550 | 51 | 75.3 | 109.5 | 1,370 | – | 5,775 |
| TRX BD TA 0550 | 51 | 75.3 | 109.5 | 1,370 | – | 5,775 |
| TRX CU LS 0550 | – | 79.8 | 103.6 | 1,370 | – | 5,500 |
| TRX CU MC 0550 | – | 79.8 | 103.6 | 1,370 | – | 5,500 |
| TRX CU ST 0550 | – | 79.8 | 103.6 | 1,370 | – | 5,500 |
| TRX CU TA 0550 | – | 79.8 | 103.6 | 1,370 | – | 5,500 |
| TRX IV LS 0550 | 51.5 | 80.2 | 100.6 | 846 | 3750 × 1400 × 2646 | 3,763 |
| TRX IV MC 0550 | 51.5 | 80.2 | 100.6 | 846 | 3750 × 1400 × 2646 | 3,621 |
| TRX IV ST 0550 | 51.5 | 80.2 | 100.6 | 846 | 3750 × 1400 × 2646 | 3,763 |
| TRX IV TA 0550 | 51.5 | 80.2 | 100.6 | 846 | 3750 × 1400 × 2646 | 3,763 |
| TRX KF TA 0550 | 34 | 50 | 70 | 810 | 3750 × 1500 × 2500 | 2,885 |
| TRX P LS 0550 | 53 | 76 | 100 | 819 | 4050 × 1600 × 2615 | 4,317 |
| TRX P MC 0550 | 53 | 76 | 100 | 819 | 4050 × 1600 × 2615 | 4,317 |
| TRX P ST 0550 | 53 | 76 | 100 | 819 | 4050 × 1600 × 2615 | 4,504 |
| TRX P TA 0550 | 53 | 76 | 100 | 819 | 4050 × 1600 × 2615 | 4,504 |
| TRX SC MC 0550 | 47 | 71 | 100 | 1,370 | – | 5,775 |
| TRX SC ST 0550 | 47 | 71 | 100 | 1,370 | – | 5,775 |
| TRX SC TA 0550 | 47 | 71 | 100 | 1,370 | – | 5,775 |
| TRX SD TA 0550 | 53.6 | 75.8 | 100.4 | 1,370 | – | 5,775 |
| TRX VL MC 0550 | 50.6 | 75.5 | 97.1 | 979 | 4089 × 1420 × 2566 | 4,189 |
| TRX VL ST 0550 | 50.6 | 75.5 | 97.1 | 979 | 4089 × 1420 × 2566 | 4,374 |
| TRX VL TA 0550 | 50.6 | 75.5 | 97.1 | 979 | 4089 × 1420 × 2566 | 4,374 |
| TRX YC TA 0550 | 54.7 | 80.6 | 110.1 | 810 | 4640 × 1600 × 2750 | 4,555 |
What can a 500 kVA generator supply?
At a power factor of 0.8, 500 kVA corresponds to about 400 kW of active power. On a 400 V three-phase supply, the full-load current is about 722 A.
Generators in this power range are typically used for:
- Factories and production plants
- Hospitals, shopping centres and large commercial buildings
- Server rooms and telecom centres
- Large construction sites and infrastructure projects
These examples are general information; the same rating does not cover the same load at every site. Sizing must be based on the total power of the connected equipment, motor starting currents and how much runs at the same time.
To calculate the required rating from a list of equipment: Power Calculator
What determines the price of a 500 kVA generator
Two generators of the same rating can differ in price depending on the equipment chosen. The main factors are:
- Engine brand and model
- Alternator brand and model
- Enclosure: soundproof canopy or open type
- Control panel and automatic transfer switch (ATS)
- Fuel tank capacity
- Delivery location and transport
A written price quote is prepared once you send us your power requirement and preferred equipment.
Frequently asked questions
How many kW is a 500 kVA generator?
At a power factor of 0.8, 500 kVA equals 400 kW of active power (kW = kVA × 0.8). The models on this page have standby ratings of 352–440 kW.
How much fuel does a 500 kVA generator use per hour?
According to manufacturer data, the models on this page use 50–80.6 litres per hour at 75% load. Consumption varies with load, engine and operating conditions; each model’s values are on its product page.
What does the price of a 500 kVA generator depend on?
The price depends on the engine and alternator brand, the enclosure (canopy or open type), the control panel and ATS, the fuel tank capacity and the delivery location. A written price quote is prepared once you send us your power requirement and preferred equipment.
Request a quote for a 500 kVA generator
Tell us your power requirement, duty (standby or prime) and delivery location, and we will prepare a quote for your project.