Knowledge Centre
Practical guides on generator sizing, fuel, maintenance, installation and 50/60 Hz for engineers and buyers.

38 articles
Selection and sizing

Sizing a Generator for Electric Motors
Running pump, compressor and fan motors from a generator: starting kVA, starting methods, voltage dip, sequential starting and drive-fed loads.

How to Choose a Construction Site Generator
Choosing a construction site generator: power by build phase, crane and welding loads, trailer or canopied set, fuel, noise, earthing and site safety.

Generators for Export: 50 Hz, 60 Hz and Voltage Selection
Buying a generator from Türkiye for export: checklist for frequency (50/60 Hz), voltage, site conditions, controller language, fuel quality and origin documents.

What Are Stage Emission Classes?
What do the Stage II, IIIA, IV and V emission classes mean? Which generators are covered, effects on engine technology and fuel, and how to specify them in tenders.

What Size Generator Do I Need?
Add running loads and the largest motor start (DOL ×3, star-delta ×2, soft starter ×1.5), add 20%, then kVA = kW ÷ 0.8. Worked example included.

Standby vs Prime vs Continuous Power
Standby: outages only, ≤200 h/year, no overload. Prime: unlimited hours at variable load, typically 10% overload 1 h in 12. Continuous: constant load.

Single-Phase or Three-Phase?
Single phase vs three phase generator: choosing by phase, voltage and current, unbalanced loads and supplying single-phase loads from a 3-phase set.

Choosing a Silent (Canopied) Generator
How to choose a silent generator: dB(A) at 7 metres, sound power vs sound pressure, soundproof canopy design, silencers and the right placement.

50 Hz vs 60 Hz Generators
50 Hz vs 60 Hz generator: 1,500 vs 1,800 rpm, engine and alternator power change, 60 Hz voltages, fuel and noise effects. Don't use a fixed multiplier.

Generator Derating for Heat and Altitude
Why do generators lose power in heat and at altitude? ISO 3046 reference conditions, derating curves, alternator effects and a worked example.

Generator Engine Brands Compared
Perkins, Cummins, Baudouin, FPT Iveco, Kofo, Kubota, Quartz, Scania, SDEC, Volvo Penta, Yangdong and Yuchai compared: origin, our power range, service network and use.

Alternator Brands Compared
Leroy-Somer, Mecc Alte, Stamford and TA-series alternators: origin, power range in our line-up, engine pairing and the technical values to check when choosing.
Buying

Economical Generator Sets with Kofo and Quartz Engines
Economical generator sets with Kofo and Quartz engines: power range, model codes, TA alternator and the projects for which they are the right choice.

Ukraine Diesel Generator Market 2024–2026
Ukraine's diesel generator imports in 2024–2026 from official statistics: totals, Türkiye, China and EU shares, power classes and seasonality.

Documents for Diesel Generator Tenders in Ukraine
Documents usually requested for diesel generator tenders in Ukraine, the martial-law conformity rule (CMU 1213) and the localization requirement for gensets.

Importing a Generator from Türkiye: Supplier Checklist
How to check a Turkish generator supplier before you order: manufacturer or broker, component models in the quote, full-load test, documents, parts.

What Is a Diesel Generator?
What is a diesel generator, how does it work and where is it used? A short, clear guide to components, advantages, selection criteria and maintenance.

Rent or Buy a Generator?
Rent or buy a generator? An impartial decision guide covering duration, criticality, total cost, maintenance responsibility and example scenarios.

What Determines Generator Price?
Why are two generators of the same kVA priced differently? How engine, alternator, rating, canopy, panel, tank, installation and currency affect price.

Generator Buying Guide
In what order do you decide when buying a generator? A practical guide: load list, rating, phase, canopy, ATS, fuel, location and quote checks.

Gas or Diesel Generator?
Gas or diesel generator? An impartial engineering comparison of load acceptance, fuel supply, storage, running hours, emissions and maintenance.
Installation and switchgear

Generator Exhaust Systems: Piping, Silencers and Back Pressure
How to design a generator exhaust line: pipe diameter, bends and length, back pressure limit, silencer grades, flexible connector, insulation and outlet.

Generator Room and Installation
Generator room ventilation and installation guide: radiator air discharge, exhaust line and back pressure, fuel, concrete plinth, vibration and earthing.

What Is an ATS? Automatic Transfer Switch
What is an ATS and how does it work? Transfer sequence, delay times, 3- or 4-pole choice, current calculation (kVA × 1.44) and a checklist.

Using a UPS with a Generator
For a 200 kVA UPS with an IGBT rectifier, plan about 250–300 kVA of generator; an older 6-pulse UPS may need twice that. Harmonics and frequency.

Generator Earthing (Grounding)
How is a generator earthed? Protective and system earthing, TN and TT systems, the neutral–earth link, ATS pole count and resistance measurement.

Paralleling (Synchronising) Generators
Generator synchronization (paralleling): sync conditions, kW and kVAr load sharing, N+1 redundancy, grid paralleling and a comparison with a single set.

Remote Generator Monitoring
How does generator remote monitoring work? Controller, GSM/4G, Ethernet, Modbus, what values to monitor, alarm settings and cyber security.
Maintenance and service

Generator Service Intervals and Maintenance Plan
How often should a generator be serviced? Intervals by running hours and calendar, standby versus prime use, maintenance records and the service plan.

Generator Maintenance Checklist
Generator maintenance checklist: daily, weekly, monthly, 250–500 hour and annual checks; battery, cooling, oil, filters, load testing and wet stacking.

What Is a Load Bank Test?
What is a load bank test and why is it done? Resistive and reactive load banks, a stepped test programme, readings to record, wet stacking and safety.

Common Generator Faults and Fixes
Generator won't start, won't take load, smokes or alarms? The most common faults, likely causes, first checks and when to call service.

Generator Spare Parts: What to Keep in Stock
Which generator spare parts should you keep in stock? A practical list of filters, belts, batteries, sensors and AVR, set by how the generator is used.

Why Generator Batteries Fail
Why does a generator battery go flat? Battery charger, temperature, parasitic drain, loose connections and age; a checklist for testing and replacement.

Starting a Generator in Cold Weather
Why is a generator hard to start in the cold? A winter checklist: block heater, preheating, winter diesel, battery, oil, antifreeze and canopy measures.
Fuel

How to Calculate Generator Fuel Consumption
A diesel generator burns about 0.28 L per kWh at full load: 100 kVA ≈ 22 L/h, 250 kVA ≈ 56 L/h. Part-load figures, tank runtime and monthly fuel examples.

Sizing a Generator Fuel Tank
Tank volume = L/h × target hours ÷ 0.85. Example: 500 kVA at 75% load for 24 hours needs about 2,370 litres. Base tank, day tank and main storage.