Containerised Generators

Containerised diesel generators above 1,100 kVA (up to 4,125 kVA) with Baudouin, Cummins and Perkins engines, full-load tested in Tuzla. Model table, quote checklist.

Terex Diesel containerised diesel generator

A containerised generator is a diesel generator set built into a steel container that serves as its enclosure and its transport frame. For high-power sets that stand outdoors, a container protects the engine and alternator from weather and dust and lets the whole set be lifted, shipped and installed as one unit.

Terex Diesel builds its sets at its facility in Tuzla, Istanbul, Türkiye, and tests every set under full load before shipment.

  • High power outdoors. Sets above 1,100 kVA are supplied in a container; sets up to 1,100 kVA are supplied with a soundproof canopy.
  • Moving as one unit. The set, its panels and its internal wiring travel together, which shortens installation and commissioning on site.
  • Harsh sites. Mines, remote construction projects, desert and coastal sites where sand, dust or salt air would shorten the life of an open-type set.

For sites that move often, see trailer-mounted generators.

Sets above 1,100 kVA, from 1,250 to 4,125 kVA standby, are supplied in a container. The table gives one example model for each power and engine brand. Baudouin sets come with three alternator options (model codes ST, MC and TA); Cummins and Perkins sets with four (ST, LS, MC and TA). Ratings are at 50 Hz, 1,500 rpm, 230/400 V, power factor 0.8.

Standby Prime Engine Fuel at 75% load Example model
1,250 kVA / 1,000 kW 1,150 kVA / 920 kW Baudouin 12M33G1250/5 175 L/h TRX BD TA 1250
1,250 kVA / 1,000 kW 1,125 kVA / 900 kW Perkins 4008-30TAG3 188 L/h TRX P ST 1250
1,375 kVA / 1,100 kW 1,250 kVA / 1,000 kW Cummins KTA50G4 206 L/h TRX CU ST 1375
1,385 kVA / 1,108 kW 1,250 kVA / 1,000 kW Perkins 4012-46TWG2A 196 L/h TRX P ST 1385
1,400 kVA / 1,120 kW 1,250 kVA / 1,000 kW Baudouin 12M33G1400/5 190.7 L/h TRX BD TA 1400
1,500 kVA / 1,200 kW 1,375 kVA / 1,100 kW Baudouin 12M33G1500/5 214.4 L/h TRX BD TA 1500
1,500 kVA / 1,200 kW 1,350 kVA / 1,080 kW Perkins 4012-46TWG3A 212 L/h TRX P ST 1500
1,650 kVA / 1,320 kW 1,500 kVA / 1,200 kW Baudouin 12M33G1650/5 234.2 L/h TRX BD TA 1650
1,650 kVA / 1,320 kW 1,500 kVA / 1,200 kW Cummins KTA50G8 222 L/h TRX CU ST 1650
1,650 kVA / 1,320 kW 1,500 kVA / 1,200 kW Perkins 4012-46TAG2A 237 L/h TRX P ST 1650
1,875 kVA / 1,500 kW 1,710 kVA / 1,368 kW Perkins 4012-46TAG3A 275 L/h TRX P ST 1875
1,900 kVA / 1,520 kW 1,750 kVA / 1,400 kW Baudouin 16M33G1900/5 265.4 L/h TRX BD TA 1900
2,000 kVA / 1,600 kW 1,830 kVA / 1,464 kW Baudouin 16M33G2000/5 290.7 L/h TRX BD TA 2000
2,000 kVA / 1,600 kW 1,850 kVA / 1,480 kW Perkins 4016-61TRG1 337 L/h TRX P ST 2000
2,200 kVA / 1,760 kW 2,000 kVA / 1,600 kW Cummins QSK60G4 291 L/h TRX CU ST 2200
2,250 kVA / 1,800 kW 2,050 kVA / 1,640 kW Baudouin 16M33G2250/5 311.3 L/h TRX BD TA 2250
2,250 kVA / 1,800 kW 2,000 kVA / 1,600 kW Perkins 4016-61TRG2 317 L/h TRX P ST 2250
2,500 kVA / 2,000 kW 2,250 kVA / 1,800 kW Baudouin 20M33G2500/5 360.7 L/h TRX BD TA 2500
2,500 kVA / 2,000 kW 2,250 kVA / 1,800 kW Cummins QSK60G8 331 L/h TRX CU ST 2500
2,500 kVA / 2,000 kW 2,250 kVA / 1,800 kW Perkins 4016-61TRG3 355 L/h TRX P ST 2500
2,750 kVA / 2,200 kW 2,500 kVA / 2,000 kW Baudouin 12M55G2750/5 381.3 L/h TRX BD TA 2750
2,750 kVA / 2,200 kW 2,500 kVA / 2,000 kW Cummins QSK60G23 – TRX CU ST 2750
3,125 kVA / 2,500 kW 2,813 kVA / 2,250 kW Baudouin 16M55G3000/5 428.3 L/h TRX BD TA 3125
3,313 kVA / 2,650 kW 3,000 kVA / 2,400 kW Baudouin 16M55G3300/5 472.5 L/h TRX BD TA 3313
3,750 kVA / 3,000 kW 3,250 kVA / 2,600 kW Baudouin 16M55G3750/5 494.7 L/h TRX BD TA 3750
4,125 kVA / 3,300 kW 3,750 kVA / 3,000 kW Baudouin 16M55G4000/5 557.2 L/h TRX BD TA 4125

All models are listed on the Baudouin, Cummins and Perkins generator pages and in the product range.

A container enclosure is designed around the site. These are the points to state in your request and to check in the quote:

Very large loads are often better served by several synchronized sets than by one. Two or more sets running in parallel let one set stop for maintenance while the others keep the load (N+1), and at low load one set can stop to save fuel and engine hours. For two sets on one base frame, see dual generator sets; for how paralleling works, see generator synchronization and parallel operation.

Containerised sets travel as a single unit. Shipping method, export documents and spare parts supply are agreed at the quotation stage. Installation and commissioning and scheduled maintenance are provided in the İstanbul and Ankara regions; for other locations, our team will contact you. Spare parts are supplied across Türkiye.

Send us the power and duty (standby or prime), voltage and frequency, ambient temperature range, altitude, noise limit, fuel autonomy and delivery point through the contact page. If you are not sure of the power, start with what size generator do I need?.

Frequently asked questions

What is a containerised generator?

A containerised generator is a diesel generator set installed inside a steel container that acts as its enclosure and transport frame, with air inlets, an exhaust outlet and service doors. It protects the set outdoors and lets a large generator be transported and installed as one unit.

When should I choose a container instead of a canopy?

The choice follows the power rating: sets up to 1,100 kVA are supplied with a canopy, and sets above 1,100 kVA are supplied in a container. Site conditions, transport and service access are confirmed in the quote.

Which models are listed with a container enclosure?

All sets whose model-code power is above 1,100 kVA. In our catalogue these are the Baudouin, Cummins and Perkins sets from 1,250 to 4,125 kVA standby (1,125 to 3,750 kVA prime). Sets up to 1,100 kVA are supplied with a canopy.

Can two containerised generators run in parallel?

Yes. Two or more sets can share a load through a synchronization panel, so one set can be stopped for maintenance while the others keep supplying power. This is how N+1 redundancy is usually built for critical sites.

What information is needed for a containerised generator quote?

The required power and duty (standby or prime), voltage and frequency, highest and lowest ambient temperature, altitude, noise limit at a stated distance, fuel autonomy and whether an ATS or synchronization panel is needed. Add the delivery point and access for the crane or truck.