Open Generator Sets

Open-type diesel generator sets: use in generator rooms and enclosures, room requirements, comparison with canopied and containerised sets, and models by power.

Terex Diesel open-type diesel generator

Request a quote

Contact us directly

Call +90 216 634 34 06WhatsApp +90 533 582 26 50

Your request has been received. We will contact you as soon as possible.

Could not send. Please try again or call us. You can also reach us directly: WhatsApp +90 533 582 26 50 · info@terexdiesel.com

Too many submissions in a short time. Please try again in a few minutes.

More details? Use the full request form

An open generator set is a generator set in which the diesel engine, alternator, control panel and fuel tank are mounted on a common steel base frame without a canopy. It is also known as an “open-type generator”. Sound insulation and weather protection are not part of the set itself but of the place where it is installed: a generator room, a roofed shelter or a project-specific enclosure.

Terex Diesel has been in the generator industry since 2006. We build our open sets at our production facility in Türkiye and test every set at full load before delivery. On this page you will find how an open set is built, where it is used, what a generator room needs and our open-type models by power.

What is an open generator set?

The open set is the most basic and most compact form of a generator. Without a canopy, all parts are visible and accessible. An open set consists of the following main parts:

  • Diesel engine and alternator: Mounted on a common base frame with anti-vibration mounts.
  • Radiator and fan: The engine cooling system, aligned with the air outlet of the room.
  • Control panel: As standard, sets below 500 kVA use the Datakom DKG-309 controller and sets of 500 kVA and above use the Datakom D-500 controller.
  • Base-frame fuel tank: The tank capacity depends on the model. In installations that need a long running time, the set can be connected to an external fuel tank.
  • Exhaust outlet: The silencer and exhaust line are designed for the place where the set will be installed.

Where is an open set used?

An open set is used where the set is already protected from the weather and unauthorised access:

  • Generator room: A technical room inside the building of a hospital, office building, hotel, data centre or industrial plant. This is the most common use.
  • Shelter or plant building: Roofed areas with protected sides and ventilation, common in agriculture, irrigation and industry.
  • Project-specific enclosure: Applications where the set is built into a special canopy, a container or a vehicle. The open set is the basis of these solutions.
  • Parallel systems: Installations where several sets run synchronised in the same room; see synchronization panels.

An open set should not be placed directly outdoors, as it is not protected against rain, dust or unauthorised access. For outdoor use, choose canopied generator sets.

Generator room requirements

Whether an open set runs correctly depends largely on how the room is prepared. The main points are:

  • Air inlet and outlet: There must be enough fresh air for the engine’s combustion air and the radiator’s cooling air. The air heated by the radiator should be ducted straight outside and must not return into the room.
  • Exhaust line: The exhaust gas must be led out of the building through a tight line and a silencer, away from areas where people are present and away from air inlets.
  • Base: The set should stand on a level concrete plinth that can carry its weight, with anti-vibration mounts so that vibration is not transferred to the building.
  • Fuel: Day tank and external tank connections, the fuel line and spill protection should be planned.
  • Maintenance space: Enough clearance should be left around the set for maintenance.
  • Noise: The noise of an open set is controlled by the insulation of the room. In buildings with a noise limit, attenuating louvres are added to the air inlets and outlets.

We cover these points in more detail in our article on generator rooms and installation. For room preparation and set selection you can use our site survey and power assessment service.

Open, canopied and containerised sets compared

Open set Canopied set Containerised set
Installation Generator room, shelter or project-specific enclosure Outdoors; no separate room needed Outdoors; high-power installations
Power range (Terex) 10–2,750 kVA From the smallest set up to 1,100 kVA Above 1,100 kVA
Sound insulation None; depends on the room insulation By the canopy; series figure ±75 dB(A) @7 m By the container insulation
Weather protection Building or enclosure protects Canopy protects Container protects
Footprint Smallest Larger because of the canopy Largest
Installation work Room ventilation, exhaust line, fuel line Base, cabling and exhaust direction Base, cabling, crane positioning
Maintenance access Open from all sides Through the canopy doors From inside the container

In short: if a generator room or a protected area is available, an open set is the most compact and usually the most economical solution. Without a room, a canopied set is used, and at very high ratings a containerised generator.

Power range and engine options

Our open sets cover ratings from 10 kVA to 2,750 kVA; models with higher ratings are supplied in a container. Engine options come from Perkins, Baudouin, Cummins, FPT Iveco, Kofo, Kubota, Quartz, Scania, SDEC, Volvo Penta, Yangdong and Yuchai. The table below shows the number of models in each power range, the engine brands and the open-set weight and tank values. Each row links to the power page that lists all models at that rating.

For high power needs, dual generator sets, with two sets running synchronised on one base frame, are another option.

Production and quality

Our sets are built in our 2,000 m² production area in Türkiye and every set is tested at full load before delivery. Our production complies with ISO 9001, CE and TSE-HYB. For export shipments we provide the certificate of origin.

If your existing open set needs a canopy, see the generator canopies page. If you are not sure which rating you need, use the power calculator or fill in the form at the top of this page.

Open models by power

The table is generated from our product data. Weight and fuel tank values refer to this enclosure type. Detailed technical data for each model is on the power page and the model page. 625 models in total

Power pageStandby powerModelsEngine brandsWeightFuel tankExample model
10–15 kVA10–15 kVA12Perkins, Kubota, Yangdong329–530 kg70–82 LTRX P ST 0010
20 kVA Diesel Generator16–22 kVA23Perkins, Baudouin, Cummins, FPT Iveco, Kubota, Yangdong456–725 kg70–135 LTRX BD TA 0020
30 kVA Diesel Generator25–38 kVA32Perkins, Baudouin, Cummins, FPT Iveco, Kofo, Kubota, Quartz, Yangdong, Yuchai490–965 kg82–135 LTRX YD TA 0030
50 kVA Diesel Generator40–58 kVA43Perkins, Baudouin, Cummins, FPT Iveco, Kofo, Kubota, Quartz, Yangdong591–1,230 kg100–220 LTRX BD TA 0050
75 kVA Diesel Generator66–88 kVA42Perkins, Baudouin, Cummins, FPT Iveco, Kofo, Quartz, SDEC, Yangdong, Yuchai763–1,400 kg101–300 LTRX YD TA 0075
100 kVA Diesel Generator90–110 kVA33Perkins, Baudouin, Cummins, FPT Iveco, Kofo, Quartz, SDEC, Yangdong, Yuchai983–1,600 kg125–310 LTRX SD TA 0100
150 kVA Diesel Generator125–170 kVA46Perkins, Baudouin, Cummins, FPT Iveco, Kofo, Quartz, SDEC, Yuchai1,160–2,310 kg265–320 LTRX BD TA 0150
200 kVA Diesel Generator175–225 kVA42Perkins, Baudouin, Cummins, FPT Iveco, Kofo, Quartz, SDEC, Volvo Penta, Yuchai1,322–2,700 kg265–415 LTRX CU ST 0200
250 kVA Diesel Generator235–300 kVA44Perkins, Baudouin, Cummins, FPT Iveco, Kofo, Quartz, Scania, SDEC, Volvo Penta, Yuchai1,495–3,200 kg265–550 LTRX BD TA 0250
400 kVA Diesel Generator305–415 kVA63Perkins, Baudouin, Cummins, FPT Iveco, Kofo, Quartz, Scania, SDEC, Volvo Penta, Yuchai2,020–4,575 kg350–1,370 LTRX BD TA 0400
500 kVA Diesel Generator440–550 kVA67Perkins, Baudouin, Cummins, FPT Iveco, Kofo, Scania, SDEC, Volvo Penta, Yuchai2,570–5,450 kg810–1,370 LTRX BD TA 0500
650 kVA Diesel Generator600–700 kVA29Perkins, Baudouin, Cummins, FPT Iveco, Scania, SDEC, Volvo Penta, Yuchai3,644–7,482 kg846–1,860 LTRX BD TA 0660
800 kVA Diesel Generator715–825 kVA40Perkins, Baudouin, Cummins, Scania, SDEC, Volvo Penta, Yuchai4,149–8,100 kg840–1,860 LTRX SD TA 0800
1000 kVA Diesel Generator900–1,120 kVA31Perkins, Baudouin, Cummins, SDEC, Yuchai6,211–9,750 kg990–2,175 LTRX BD TA 1000
1250 kVA Diesel Generator1,250–1,400 kVA20Perkins, Baudouin, Cummins, Yuchai8,215–10,895 kg990–2,395 LTRX BD TA 1250
1500 kVA Diesel Generator1,500–1,650 kVA18Perkins, Baudouin, Cummins9,241–11,500 kg2,338–2,395 LTRX BD TA 1500
2000 kVA Diesel Generator1,875–2,250 kVA25Perkins, Baudouin, Cummins11,858–14,576 kg2,350–3,000 LTRX BD TA 2000
2500 kVA Diesel Generator2,500–2,750 kVA15Perkins, Baudouin, Cummins12,850–15,092 kg2,350–3,000 LTRX BD TA 2500

Frequently asked questions

What is an open generator set?

An open (open-type) generator set is a set in which the diesel engine, alternator, control panel and fuel tank are mounted on a common base frame without a canopy. Sound insulation and weather protection are provided by the generator room or enclosure in which the set is installed.

Can an open generator set be used outdoors?

An open set is not protected against rain, dust or unauthorised access, so placing it directly outdoors is not recommended. It is installed in a generator room, a roofed and ventilated shelter or a project-specific enclosure. For outdoor use, a canopied or containerised set is the right choice.

What should a generator room provide?

The room needs enough air inlet for cooling and combustion air and an outlet for the hot radiator air, the exhaust line must be led safely out of the building, the set must be mounted so that vibration is not transferred to the floor, and the fuel line and maintenance space must be planned. Details are in our article on generator rooms and installation.

What is the advantage of an open set over a canopied set?

If a generator room already exists, an open set takes up less space, gives maintenance access from all sides and, without the cost of a canopy, is usually more economical. Sound insulation is provided by the insulation of the room.

In which ratings are open sets available?

Our open sets cover ratings from 10 kVA to 2,750 kVA. Models with higher ratings are supplied in a container. The table below shows the number of models by power and the open-set weight and tank values.

Can a canopy be added to an open set later?

Yes. After checking the dimensions of the set and the position of the radiator and exhaust, a suitable canopy can be designed and built for an existing open set. See our generator canopies page or contact us for details.