250 kVA (200 kW) Diesel Generator

This page lists 44 diesel generator models with standby ratings of 235–300 kVA (188–240 kW). Ratings listed: 235, 236, 250, 260, 275, and 300 kVA.

Get price and lead timeView models

Terex Diesel canopied diesel generator

Request a quote

Tell us your power requirement, duty (standby or prime) and delivery location, and we will prepare a quote for your project.

Contact us directly

Call +90 216 634 34 06WhatsApp +90 533 582 26 50

Your request has been received. We will contact you as soon as possible.

Could not send. Please try again or call us. You can also reach us directly: WhatsApp +90 533 582 26 50 · info@terexdiesel.com

Too many submissions in a short time. Please try again in a few minutes.

Phone or email (one is enough)

Terms for sales outside Türkiye

  • Dispatch

    Models in stock: 2–3 business days; Perkins, Cummins, Volvo, Kubota, Scania and FPT Iveco: 3–4 weeks after order.

  • Warranty outside Türkiye

    12 months or 1,000 operating hours for all engine brands.

  • Certificates

    ISO 9001 · CE · TSE-HYB

  • Export documents

    A commercial invoice and packing list are prepared; a certificate of origin and any other documents the buyer requires are issued on request.

Export Process and Payment

Key figures

Models
44
Standby power range
235–300 kVA
Engine brands
Perkins, Baudouin, Cummins, FPT Iveco, Kofo, Quartz, Scania, SDEC, Volvo Penta, Yuchai
Fuel consumption (75% load)
30.5–45.8 L/h
Weight with canopy
1,695–3,500 kg
Typical canopy dimensions (L × W × H)
3600 × 1200 × 2288 mm

Figures are calculated from the technical data of the models on this page; per-model values are on each product page.

Models rated 235–300 kVA standby

The table shows each model’s standby and prime ratings, engine and alternator; click a model name for full specifications. Use the compare button in the table to view models side by side.

Models rated 235–300 kVA standby
ModelStandby (kVA)Prime (kVA)EngineAlternatorFrequencyCompareView
TRX QZ TA 0235235211.5Quartz Q6113AZLDTerex TA280-170N50 HzView: TRX QZ TA 0235Request a Quote: TRX QZ TA 0235
TRX SD TA 0236236215SDEC SC9D280D2Terex TA280-220N50 HzView: TRX SD TA 0236Request a Quote: TRX SD TA 0236
TRX BD MC 0250250230Baudouin 6M16G4D0/SMecc Alte ECO38-1M/450 HzView: TRX BD MC 0250Request a Quote: TRX BD MC 0250
TRX BD ST 0250250230Baudouin 6M16G4D0/SStamford UCDI274K50 HzView: TRX BD ST 0250Request a Quote: TRX BD ST 0250
TRX BD TA 0250250230Baudouin 6M16G4D0/STerex TA280-220N50 HzView: TRX BD TA 0250Request a Quote: TRX BD TA 0250
TRX KF TA 0250250225Kofo 6126-42DTerex TA280-220N50 HzView: TRX KF TA 0250Request a Quote: TRX KF TA 0250
TRX P LS 0250250230Perkins 1206A-E70TTAG2Leroy-Somer TAL046 C50 HzView: TRX P LS 0250Request a Quote: TRX P LS 0250
TRX P MC 0250250230Perkins 1206A-E70TTAG2Mecc Alte ECO38-1M/450 HzView: TRX P MC 0250Request a Quote: TRX P MC 0250
TRX P ST 0250250230Perkins 1206A-E70TTAG2Stamford UCDI274K50 HzView: TRX P ST 0250Request a Quote: TRX P ST 0250
TRX P TA 0250250230Perkins 1206A-E70TTAG2Terex TA280-220N50 HzView: TRX P TA 0250Request a Quote: TRX P TA 0250
TRX SC MC 0250250200Scania DC09072A 02-11Mecc Alte ECO38-1M/450 HzView: TRX SC MC 0250Request a Quote: TRX SC MC 0250
TRX SC ST 0250250200Scania DC09072A 02-11Stamford UCDI274K50 HzView: TRX SC ST 0250Request a Quote: TRX SC ST 0250
TRX SC TA 0250250200Scania DC09072A 02-11Terex TA280-220N50 HzView: TRX SC TA 0250Request a Quote: TRX SC TA 0250
TRX SD TA 0260260236SDEC SC9D310D2Terex TA280-220N50 HzView: TRX SD TA 0260Request a Quote: TRX SD TA 0260
TRX BD MC 0275275250Baudouin 6M16G6D0/SMecc Alte ECO38-2M/450 HzView: TRX BD MC 0275Request a Quote: TRX BD MC 0275
TRX BD ST 0275275250Baudouin 6M16G6D0/SStamford UCDI274K50 HzView: TRX BD ST 0275Request a Quote: TRX BD ST 0275
TRX BD TA 0275275250Baudouin 6M16G6D0/STerex TA280-220N50 HzView: TRX BD TA 0275Request a Quote: TRX BD TA 0275
TRX CU LS 0275275250Cummins 6L8.9TAA-G4Leroy-Somer TAL046 D50 HzView: TRX CU LS 0275Request a Quote: TRX CU LS 0275
TRX CU MC 0275275250Cummins 6L8.9TAA-G4Mecc Alte ECO38-2M/450 HzView: TRX CU MC 0275Request a Quote: TRX CU MC 0275
TRX CU ST 0275275250Cummins 6L8.9TAA-G4Stamford HCI444D50 HzView: TRX CU ST 0275Request a Quote: TRX CU ST 0275
TRX CU TA 0275275250Cummins 6L8.9TAA-G4Terex TA280-220N50 HzView: TRX CU TA 0275Request a Quote: TRX CU TA 0275
TRX IV LS 0275275250FPT Iveco NEF67TE8WLeroy-Somer TAL046 D50 HzView: TRX IV LS 0275Request a Quote: TRX IV LS 0275
TRX IV MC 0275275250FPT Iveco NEF67TE8WMecc Alte ECO38-2M/450 HzView: TRX IV MC 0275Request a Quote: TRX IV MC 0275
TRX IV ST 0275275250FPT Iveco NEF67TE8WStamford UCDI274K50 HzView: TRX IV ST 0275Request a Quote: TRX IV ST 0275
TRX IV TA 0275275250FPT Iveco NEF67TE8WTerex TA280-220N50 HzView: TRX IV TA 0275Request a Quote: TRX IV TA 0275
TRX KF TA 0275275250Kofo WT10B-231DTerex TA280-240N50 HzView: TRX KF TA 0275Request a Quote: TRX KF TA 0275
TRX P LS 0275275250Perkins 1206A-E70TTAG3Leroy-Somer TAL046 D50 HzView: TRX P LS 0275Request a Quote: TRX P LS 0275
TRX P MC 0275275250Perkins 1206A-E70TTAG3Mecc Alte ECO38-2M/450 HzView: TRX P MC 0275Request a Quote: TRX P MC 0275
TRX P ST 0275275250Perkins 1206A-E70TTAG3Stamford UCDI274K50 HzView: TRX P ST 0275Request a Quote: TRX P ST 0275
TRX P TA 0275275250Perkins 1206A-E70TTAG3Terex TA280-220N50 HzView: TRX P TA 0275Request a Quote: TRX P TA 0275
TRX SD TA 0275275250SDEC SC9D310D2Terex TA280-220N50 HzView: TRX SD TA 0275Request a Quote: TRX SD TA 0275
TRX VL MC 0275275250Volvo Penta TAD841GEMecc Alte ECO38-2M/450 HzView: TRX VL MC 0275Request a Quote: TRX VL MC 0275
TRX VL ST 0275275250Volvo Penta TAD841GEStamford UCDI274K50 HzView: TRX VL ST 0275Request a Quote: TRX VL ST 0275
TRX VL TA 0275275250Volvo Penta TAD841GETerex TA280-220N50 HzView: TRX VL TA 0275Request a Quote: TRX VL TA 0275
TRX YC TA 0275275250Yuchai YC6MK350L-D20Terex TA280-220N50 HzView: TRX YC TA 0275Request a Quote: TRX YC TA 0275
TRX BD MC 0300300275Baudouin 6M16G300/5Mecc Alte ECO38-1L/450 HzView: TRX BD MC 0300Request a Quote: TRX BD MC 0300
TRX BD ST 0300300275Baudouin 6M16G300/5Stamford S4L1D-D50 HzView: TRX BD ST 0300Request a Quote: TRX BD ST 0300
TRX BD TA 0300300275Baudouin 6M16G300/5Terex TA280-240N50 HzView: TRX BD TA 0300Request a Quote: TRX BD TA 0300
TRX CU ST 0300300270Cummins 6LTAA9.5-G3Stamford HCI444D50 HzView: TRX CU ST 0300Request a Quote: TRX CU ST 0300
TRX P ST 0300300275Perkins 1506A-E88TAG4Stamford S4L1D-D50 HzView: TRX P ST 0300Request a Quote: TRX P ST 0300
TRX SC MC 0300300240Scania DC09072A 02-13Mecc Alte ECO38-1L/450 HzView: TRX SC MC 0300Request a Quote: TRX SC MC 0300
TRX SC ST 0300300240Scania DC09072A 02-13Stamford S4L1D-D50 HzView: TRX SC ST 0300Request a Quote: TRX SC ST 0300
TRX SC TA 0300300240Scania DC09072A 02-13Terex TA280-240N50 HzView: TRX SC TA 0300Request a Quote: TRX SC TA 0300
TRX SD TA 0300300273SDEC SC9D340D2Terex TA280-240N50 HzView: TRX SD TA 0300Request a Quote: TRX SD TA 0300

Not sure how much power you need? Let’s calculate it together

Fuel consumption, tank, dimensions and weight

Values are taken from our product data. Dimension, weight and tank columns are for the Canopied (soundproof) version; fields without data are shown as "–".

ModelAt 50% load (L/h)At 75% load (L/h)At 100% load (L/h)Fuel tank (L)Dimensions (L × W × H) (mm)Weight (kg)
TRX QZ TA 023520.630.5412653000 × 1100 × 18502,650
TRX SD TA 023624.336.248.64153600 × 1200 × 22882,121
TRX BD MC 025025.83850.94153600 × 1200 × 22882,520
TRX BD ST 025025.83850.94153600 × 1200 × 22882,633
TRX BD TA 025025.83850.94153600 × 1200 × 22882,633
TRX KF TA 02502131412653000 × 1100 × 18501,695
TRX P LS 025025.538514153600 × 1200 × 22882,216
TRX P MC 025025.538514153600 × 1200 × 22882,142
TRX P ST 025025.538514153600 × 1200 × 22882,269
TRX P TA 025025.538514153600 × 1200 × 22882,269
TRX SC MC 025026.137.750.82653000 × 1100 × 18502,790
TRX SC ST 025026.137.750.82653000 × 1100 × 18502,790
TRX SC TA 025026.137.750.82653000 × 1100 × 18502,790
TRX SD TA 026026.338.250.64153600 × 1200 × 22882,271
TRX BD MC 027528.342.256.94153600 × 1200 × 22882,482
TRX BD ST 027528.342.256.94153600 × 1200 × 22882,554
TRX BD TA 027528.342.256.94153600 × 1200 × 22882,554
TRX CU LS 0275294256350–3,150
TRX CU MC 0275294256350–3,150
TRX CU ST 0275294256350–3,150
TRX CU TA 0275294256350–3,150
TRX IV LS 027526.241.251.5350–3,150
TRX IV MC 027526.241.251.5350–3,150
TRX IV ST 027526.241.251.5350–3,150
TRX IV TA 027526.241.251.5350–3,150
TRX KF TA 02752132453503400 × 1200 × 21002,090
TRX P LS 027528.141.556.94153600 × 1200 × 22882,599
TRX P MC 027528.141.556.94153600 × 1200 × 22882,570
TRX P ST 027528.141.556.94153600 × 1200 × 22882,644
TRX P TA 027528.141.556.94153600 × 1200 × 22882,644
TRX SD TA 0275263850.64153600 × 1200 × 22882,271
TRX VL MC 0275––604153600 × 1200 × 22883,150
TRX VL ST 0275––604153600 × 1200 × 22883,150
TRX VL TA 0275––604153600 × 1200 × 22883,150
TRX YC TA 027528.842.757.25503500 × 1250 × 22802,534
TRX BD MC 030032.645.258.84153600 × 1200 × 22882,523
TRX BD ST 030032.645.258.84153600 × 1200 × 22882,690
TRX BD TA 030032.645.258.84153600 × 1200 × 22882,690
TRX CU ST 03002942565503500 × 1250 × 22802,564
TRX P ST 030031.645.860.24153600 × 1200 × 22882,857
TRX SC MC 030030.144.361.6350–3,150
TRX SC ST 030030.144.361.6350–3,150
TRX SC TA 030030.144.361.6350–3,150
TRX SD TA 030027.340.854.1350–3,500

What can a 250 kVA generator supply?

At a power factor of 0.8, 250 kVA corresponds to about 200 kW of active power. On a 400 V three-phase supply, the full-load current is about 361 A.

Generators in this power range are typically used for:

  • Shared services of residential complexes
  • Hotels, schools and commercial buildings
  • Medium-sized workshops and production lines
  • Cranes, welding machines and equipment on construction sites
  • Agricultural irrigation and cold stores

These examples are general information; the same rating does not cover the same load at every site. Sizing must be based on the total power of the connected equipment, motor starting currents and how much runs at the same time.

To calculate the required rating from a list of equipment: Power Calculator

What determines the price of a 250 kVA generator

Two generators of the same rating can differ in price depending on the equipment chosen. The main factors are:

  • Engine brand and model
  • Alternator brand and model
  • Enclosure: soundproof canopy or open type
  • Control panel and automatic transfer switch (ATS)
  • Fuel tank capacity
  • Delivery location and transport

A written price quote is prepared once you send us your power requirement and preferred equipment.

Get price and lead timeCall +90 216 634 34 06

Frequently asked questions

How many kW is a 250 kVA generator?

At a power factor of 0.8, 250 kVA equals 200 kW of active power (kW = kVA × 0.8). The models on this page have standby ratings of 188–240 kW.

How much fuel does a 250 kVA generator use per hour?

According to manufacturer data, the models on this page use 30.5–45.8 litres per hour at 75% load. Consumption varies with load, engine and operating conditions; each model’s values are on its product page.