200 kVA (160 kW) Diesel Generator

This page lists 42 diesel generator models with standby ratings of 175–225 kVA (140–180 kW). Ratings listed: 175, 185, 200, 220, and 225 kVA.

Get price and lead timeView models

Terex Diesel canopied diesel generator

Request a quote

Tell us your power requirement, duty (standby or prime) and delivery location, and we will prepare a quote for your project.

Contact us directly

Call +90 216 634 34 06WhatsApp +90 533 582 26 50

Your request has been received. We will contact you as soon as possible.

Could not send. Please try again or call us. You can also reach us directly: WhatsApp +90 533 582 26 50 · info@terexdiesel.com

Too many submissions in a short time. Please try again in a few minutes.

Phone or email (one is enough)

Terms for sales outside Türkiye

  • Dispatch

    Models in stock: 2–3 business days; Perkins, Cummins, Volvo, Kubota, Scania and FPT Iveco: 3–4 weeks after order.

  • Warranty outside Türkiye

    12 months or 1,000 operating hours for all engine brands.

  • Certificates

    ISO 9001 · CE · TSE-HYB

  • Export documents

    A commercial invoice and packing list are prepared; a certificate of origin and any other documents the buyer requires are issued on request.

Export Process and Payment

Key figures

Models
42
Standby power range
175–225 kVA
Engine brands
Perkins, Baudouin, Cummins, FPT Iveco, Kofo, Quartz, SDEC, Volvo Penta, Yuchai
Fuel consumption (75% load)
20.4–34.7 L/h
Weight with canopy
1,522–3,040 kg
Typical canopy dimensions (L × W × H)
3220 × 1100 × 1913 mm

Figures are calculated from the technical data of the models on this page; per-model values are on each product page.

Models rated 175–225 kVA standby

The table shows each model’s standby and prime ratings, engine and alternator; click a model name for full specifications. Use the compare button in the table to view models side by side.

Models rated 175–225 kVA standby
ModelStandby (kVA)Prime (kVA)EngineAlternatorFrequencyCompareView
TRX KF TA 0175175150Kofo 6RT80-132DTerex TA280-150N50 HzView: TRX KF TA 0175Request a Quote: TRX KF TA 0175
TRX QZ TA 0175175157.5Quartz Q6105IZLDTerex TA280-150N50 HzView: TRX QZ TA 0175Request a Quote: TRX QZ TA 0175
TRX SD TA 0175175159SDEC SC7H230D2Terex TA280-165N50 HzView: TRX SD TA 0175Request a Quote: TRX SD TA 0175
TRX IV LS 0185185165FPT Iveco NEF67TM3ALeroy-Somer TAL044 L50 HzView: TRX IV LS 0185Request a Quote: TRX IV LS 0185
TRX IV MC 0185185165FPT Iveco NEF67TM3AMecc Alte ECO38-2S/450 HzView: TRX IV MC 0185Request a Quote: TRX IV MC 0185
TRX IV ST 0185185165FPT Iveco NEF67TM3AStamford UCI274G50 HzView: TRX IV ST 0185Request a Quote: TRX IV ST 0185
TRX IV TA 0185185165FPT Iveco NEF67TM3ATerex TA280-165N50 HzView: TRX IV TA 0185Request a Quote: TRX IV TA 0185
TRX CU LS 0200200180Cummins QSB6.7-G14Leroy-Somer TAL044 L50 HzView: TRX CU LS 0200Request a Quote: TRX CU LS 0200
TRX CU MC 0200200180Cummins QSB6.7-G14Mecc Alte ECO38-2S/450 HzView: TRX CU MC 0200Request a Quote: TRX CU MC 0200
TRX CU ST 0200200180Cummins QSB6.7-G14Stamford UCI274H50 HzView: TRX CU ST 0200Request a Quote: TRX CU ST 0200
TRX CU TA 0200200180Cummins QSB6.7-G14Terex TA280-170N50 HzView: TRX CU TA 0200Request a Quote: TRX CU TA 0200
TRX IV LS 0200200180FPT Iveco NEF67TM4Leroy-Somer TAL044 L50 HzView: TRX IV LS 0200Request a Quote: TRX IV LS 0200
TRX IV MC 0200200180FPT Iveco NEF67TM4Mecc Alte ECO38-2S/450 HzView: TRX IV MC 0200Request a Quote: TRX IV MC 0200
TRX IV ST 0200200180FPT Iveco NEF67TM4Stamford UCI274G50 HzView: TRX IV ST 0200Request a Quote: TRX IV ST 0200
TRX IV TA 0200200180FPT Iveco NEF67TM4Terex TA280-165N50 HzView: TRX IV TA 0200Request a Quote: TRX IV TA 0200
TRX P LS 0200200180Perkins 1106A-70TAG3Leroy-Somer TAL044 L50 HzView: TRX P LS 0200Request a Quote: TRX P LS 0200
TRX P MC 0200200180Perkins 1106A-70TAG3Mecc Alte ECO38-2S/450 HzView: TRX P MC 0200Request a Quote: TRX P MC 0200
TRX P ST 0200200180Perkins 1106A-70TAG3Stamford UCI274G50 HzView: TRX P ST 0200Request a Quote: TRX P ST 0200
TRX P TA 0200200180Perkins 1106A-70TAG3Terex TA280-165N50 HzView: TRX P TA 0200Request a Quote: TRX P TA 0200
TRX QZ TA 0200200172Quartz Q6108IZLDTerex TA280-170N50 HzView: TRX QZ TA 0200Request a Quote: TRX QZ TA 0200
TRX SD TA 0200200182SDEC SC7H230D2Terex TA280-165N50 HzView: TRX SD TA 0200Request a Quote: TRX SD TA 0200
TRX YC TA 0200200187.5Yuchai YC6A245L-D21Terex TA280-165N50 HzView: TRX YC TA 0200Request a Quote: TRX YC TA 0200
TRX BD MC 0220220200Baudouin 6M16G2D0/SMecc Alte ECO38-2S/450 HzView: TRX BD MC 0220Request a Quote: TRX BD MC 0220
TRX BD ST 0220220200Baudouin 6M16G2D0/SStamford UCI274H50 HzView: TRX BD ST 0220Request a Quote: TRX BD ST 0220
TRX BD TA 0220220200Baudouin 6M16G2D0/STerex TA280-170N50 HzView: TRX BD TA 0220Request a Quote: TRX BD TA 0220
TRX CU LS 0220220200Cummins QSB6.7-G15Leroy-Somer TAL044 M50 HzView: TRX CU LS 0220Request a Quote: TRX CU LS 0220
TRX CU MC 0220220200Cummins QSB6.7-G15Mecc Alte ECO38-2S/450 HzView: TRX CU MC 0220Request a Quote: TRX CU MC 0220
TRX CU ST 0220220200Cummins QSB6.7-G15Stamford UCI274K50 HzView: TRX CU ST 0220Request a Quote: TRX CU ST 0220
TRX CU TA 0220220200Cummins QSB6.7-G15Terex TA280-170N50 HzView: TRX CU TA 0220Request a Quote: TRX CU TA 0220
TRX IV LS 0220220200FPT Iveco NEF67TM7Leroy-Somer TAL044 M50 HzView: TRX IV LS 0220Request a Quote: TRX IV LS 0220
TRX IV MC 0220220200FPT Iveco NEF67TM7Mecc Alte ECO38-2S/450 HzView: TRX IV MC 0220Request a Quote: TRX IV MC 0220
TRX IV ST 0220220200FPT Iveco NEF67TM7Stamford UCI274H50 HzView: TRX IV ST 0220Request a Quote: TRX IV ST 0220
TRX IV TA 0220220200FPT Iveco NEF67TM7Terex TA280-170N50 HzView: TRX IV TA 0220Request a Quote: TRX IV TA 0220
TRX P LS 0220220200Perkins 1106A-70TAG4Leroy-Somer TAL044 M50 HzView: TRX P LS 0220Request a Quote: TRX P LS 0220
TRX P MC 0220220200Perkins 1106A-70TAG4Mecc Alte ECO38-2S/450 HzView: TRX P MC 0220Request a Quote: TRX P MC 0220
TRX P ST 0220220200Perkins 1106A-70TAG4Stamford UCI274H50 HzView: TRX P ST 0220Request a Quote: TRX P ST 0220
TRX P TA 0220220200Perkins 1106A-70TAG4Terex TA280-170N50 HzView: TRX P TA 0220Request a Quote: TRX P TA 0220
TRX VL MC 0220220200Volvo Penta TAD840GEMecc Alte ECO38-2S/450 HzView: TRX VL MC 0220Request a Quote: TRX VL MC 0220
TRX VL ST 0220220200Volvo Penta TAD840GEStamford UCI274H50 HzView: TRX VL ST 0220Request a Quote: TRX VL ST 0220
TRX VL TA 0220220200Volvo Penta TAD840GETerex TA280-170N50 HzView: TRX VL TA 0220Request a Quote: TRX VL TA 0220
TRX KF TA 0225225203Kofo 6RT80-176DETerex TA280-170N50 HzView: TRX KF TA 0225Request a Quote: TRX KF TA 0225
TRX SD TA 0225225205SDEC SC7H250D2Terex TA280-170N50 HzView: TRX SD TA 0225Request a Quote: TRX SD TA 0225

Not sure how much power you need? Let’s calculate it together

Fuel consumption, tank, dimensions and weight

Values are taken from our product data. Dimension, weight and tank columns are for the Canopied (soundproof) version; fields without data are shown as "–".

ModelAt 50% load (L/h)At 75% load (L/h)At 100% load (L/h)Fuel tank (L)Dimensions (L × W × H) (mm)Weight (kg)
TRX KF TA 01751420.426.92653000 × 1100 × 18501,522
TRX QZ TA 017515.522.830.82653000 × 1100 × 18502,450
TRX SD TA 017517.826.8364153600 × 1200 × 22881,930
TRX IV LS 01851829362723220 × 1100 × 18451,755
TRX IV MC 01851829362723220 × 1100 × 18451,665
TRX IV ST 01851829362723220 × 1100 × 18451,755
TRX IV TA 01851829362723220 × 1100 × 18451,755
TRX CU LS 0200–34452653000 × 1100 × 18502,790
TRX CU MC 0200–34452653000 × 1100 × 18502,790
TRX CU ST 0200–34452653000 × 1100 × 18502,790
TRX CU TA 0200–34452653000 × 1100 × 18502,790
TRX IV LS 02001829.436.62653000 × 1100 × 18502,790
TRX IV MC 02001829.436.62653000 × 1100 × 18502,790
TRX IV ST 02001829.436.62653000 × 1100 × 18502,790
TRX IV TA 02001829.436.62653000 × 1100 × 18502,790
TRX P LS 020020.23241.42723220 × 1100 × 19171,936
TRX P MC 020020.23241.42723220 × 1100 × 19131,936
TRX P ST 020020.23241.42723220 × 1100 × 19431,936
TRX P TA 020020.23241.42723220 × 1100 × 19431,936
TRX QZ TA 0200––––––
TRX SD TA 020017.526.8364153600 × 1200 × 22881,930
TRX YC TA 020020.129.540.23603500 × 1100 × 22402,146
TRX BD MC 022022.432.443.14153600 × 1200 × 22882,392
TRX BD ST 022022.432.443.14153600 × 1200 × 22882,468
TRX BD TA 022022.432.443.14153600 × 1200 × 22882,468
TRX CU LS 0220–34452653000 × 1100 × 18503,040
TRX CU MC 0220–34452653000 × 1100 × 18503,040
TRX CU ST 0220–34452653000 × 1100 × 18503,040
TRX CU TA 0220–34452653000 × 1100 × 18503,040
TRX IV LS 0220–––2723220 × 1100 × 18451,780
TRX IV MC 0220–––2723220 × 1100 × 18451,775
TRX IV ST 0220–––2723220 × 1100 × 18451,780
TRX IV TA 0220–––2723220 × 1100 × 18451,780
TRX P LS 022023.134.745.82723220 × 1100 × 18451,937
TRX P MC 022023.134.745.82723220 × 1100 × 18451,933
TRX P ST 022023.134.745.82723220 × 1100 × 18452,009
TRX P TA 022023.134.745.82723220 × 1100 × 18452,009
TRX VL MC 0220––44.94153600 × 1200 × 22882,790
TRX VL ST 0220––44.94153600 × 1200 × 22882,790
TRX VL TA 0220––44.94153600 × 1200 × 22882,790
TRX KF TA 022519.628.637.62653000 × 1100 × 18501,670
TRX SD TA 022519.429.139.34153600 × 1200 × 22881,930

What can a 200 kVA generator supply?

At a power factor of 0.8, 200 kVA corresponds to about 160 kW of active power. On a 400 V three-phase supply, the full-load current is about 289 A.

Generators in this power range are typically used for:

  • Shared services of residential complexes
  • Hotels, schools and commercial buildings
  • Medium-sized workshops and production lines
  • Cranes, welding machines and equipment on construction sites
  • Agricultural irrigation and cold stores

These examples are general information; the same rating does not cover the same load at every site. Sizing must be based on the total power of the connected equipment, motor starting currents and how much runs at the same time.

To calculate the required rating from a list of equipment: Power Calculator

What determines the price of a 200 kVA generator

Two generators of the same rating can differ in price depending on the equipment chosen. The main factors are:

  • Engine brand and model
  • Alternator brand and model
  • Enclosure: soundproof canopy or open type
  • Control panel and automatic transfer switch (ATS)
  • Fuel tank capacity
  • Delivery location and transport

A written price quote is prepared once you send us your power requirement and preferred equipment.

Get price and lead timeCall +90 216 634 34 06

Frequently asked questions

How many kW is a 200 kVA generator?

At a power factor of 0.8, 200 kVA equals 160 kW of active power (kW = kVA × 0.8). The models on this page have standby ratings of 140–180 kW.

How much fuel does a 200 kVA generator use per hour?

According to manufacturer data, the models on this page use 20.4–34.7 litres per hour at 75% load. Consumption varies with load, engine and operating conditions; each model’s values are on its product page.

What does the price of a 200 kVA generator depend on?

The price depends on the engine and alternator brand, the enclosure (canopy or open type), the control panel and ATS, the fuel tank capacity and the delivery location. A written price quote is prepared once you send us your power requirement and preferred equipment.

Request a quote for a 200 kVA generator

Tell us your power requirement, duty (standby or prime) and delivery location, and we will prepare a quote for your project.

Get price and lead time

Chat on WhatsApp

Download