1000 kVA (800 kW) Diesel Generator

This page lists 31 diesel generator models with standby ratings of 900–1120 kVA (720–896 kW). Ratings listed: 900, 1000, 1010, 1100, and 1120 kVA.

Get price and lead timeView models

Terex Diesel high-output canopied diesel generator

Request a quote

Tell us your power requirement, duty (standby or prime) and delivery location, and we will prepare a quote for your project.

Contact us directly

Call +90 216 634 34 06WhatsApp +90 533 582 26 50

Your request has been received. We will contact you as soon as possible.

Could not send. Please try again or call us. You can also reach us directly: WhatsApp +90 533 582 26 50 · info@terexdiesel.com

Too many submissions in a short time. Please try again in a few minutes.

Phone or email (one is enough)

Terms for sales outside Türkiye

  • Warranty outside Türkiye

    12 months or 1,000 operating hours for all engine brands.

  • Certificates

    ISO 9001 · CE · TSE-HYB

  • Export documents

    A commercial invoice and packing list are prepared; a certificate of origin and any other documents the buyer requires are issued on request.

Export Process and Payment

Key figures

Models
31
Standby power range
900–1,120 kVA
Engine brands
Perkins, Baudouin, Cummins, SDEC, Yuchai
Fuel consumption (75% load)
121–162 L/h
Weight with canopy
7,771–10,600 kg
Typical canopy dimensions (L × W × H)
5100 × 2085 × 3434 mm

Figures are calculated from the technical data of the models on this page; per-model values are on each product page.

Models rated 900–1120 kVA standby

The table shows each model’s standby and prime ratings, engine and alternator; click a model name for full specifications. Use the compare button in the table to view models side by side.

Models rated 900–1120 kVA standby
ModelStandby (kVA)Prime (kVA)EngineAlternatorFrequencyCompareView
TRX BD MC 0900900815Baudouin 8M33G900/5Mecc Alte ECO43-1S/450 HzView: TRX BD MC 0900Request a Quote: TRX BD MC 0900
TRX BD ST 0900900815Baudouin 8M33G900/5Stamford S6L1D-D450 HzView: TRX BD ST 0900Request a Quote: TRX BD ST 0900
TRX BD TA 0900900815Baudouin 8M33G900/5Terex TA400-640N50 HzView: TRX BD TA 0900Request a Quote: TRX BD TA 0900
TRX CU ST 0900900815Cummins QSK23-G3Stamford HCI634W50 HzView: TRX CU ST 0900Request a Quote: TRX CU ST 0900
TRX P LS 0900900800Perkins 4006-23TAG3ALeroy-Somer TAL049 C50 HzView: TRX P LS 0900Request a Quote: TRX P LS 0900
TRX P MC 0900900800Perkins 4006-23TAG3AMecc Alte ECO43-1S/450 HzView: TRX P MC 0900Request a Quote: TRX P MC 0900
TRX P ST 0900900800Perkins 4006-23TAG3AStamford S6L1D-D450 HzView: TRX P ST 0900Request a Quote: TRX P ST 0900
TRX P TA 0900900800Perkins 4006-23TAG3ATerex TA400-640N50 HzView: TRX P TA 0900Request a Quote: TRX P TA 0900
TRX SD TA 0900900818SDEC 6KTAA25Terex TA400-640N50 HzView: TRX SD TA 0900Request a Quote: TRX SD TA 0900
TRX BD MC 10001,000900Baudouin 8M33G1000/5Mecc Alte ECO43-1M/450 HzView: TRX BD MC 1000Request a Quote: TRX BD MC 1000
TRX BD ST 10001,000900Baudouin 8M33G1000/5Stamford S6L1D-D450 HzView: TRX BD ST 1000Request a Quote: TRX BD ST 1000
TRX BD TA 10001,000900Baudouin 8M33G1000/5Terex TA400-700N50 HzView: TRX BD TA 1000Request a Quote: TRX BD TA 1000
TRX CU ST 10001,000910Cummins KTA38-G3Stamford HCI634Y50 HzView: TRX CU ST 1000Request a Quote: TRX CU ST 1000
TRX P LS 10001,000900Perkins 4008TAG1ALeroy-Somer TAL049 D50 HzView: TRX P LS 1000Request a Quote: TRX P LS 1000
TRX P MC 10001,000900Perkins 4008TAG1AMecc Alte ECO43-1M/450 HzView: TRX P MC 1000Request a Quote: TRX P MC 1000
TRX P ST 10001,000900Perkins 4008TAG1AStamford S6L1D-D450 HzView: TRX P ST 1000Request a Quote: TRX P ST 1000
TRX P TA 10001,000900Perkins 4008TAG1ATerex TA400-700N50 HzView: TRX P TA 1000Request a Quote: TRX P TA 1000
TRX YC TA 10001,000900Yuchai YC6TH1220-D31Terex TA400-700N50 HzView: TRX YC TA 1000Request a Quote: TRX YC TA 1000
TRX SD TA 10101,010918SDEC SC33W1150D2Terex TA400-700N50 HzView: TRX SD TA 1010Request a Quote: TRX SD TA 1010
TRX CU LS 11001,1001,010Cummins KTA38G5Leroy-Somer TAL049 E50 HzView: TRX CU LS 1100Request a Quote: TRX CU LS 1100
TRX CU MC 11001,1001,010Cummins KTA38G5Mecc Alte ECO43-1M/450 HzView: TRX CU MC 1100Request a Quote: TRX CU MC 1100
TRX CU ST 11001,1001,010Cummins KTA38G5Stamford HCI634Y50 HzView: TRX CU ST 1100Request a Quote: TRX CU ST 1100
TRX CU TA 11001,1001,010Cummins KTA38G5Terex TA400-800N50 HzView: TRX CU TA 1100Request a Quote: TRX CU TA 1100
TRX P LS 11001,1001,000Perkins 4008TAG2ALeroy-Somer TAL049 E50 HzView: TRX P LS 1100Request a Quote: TRX P LS 1100
TRX P MC 11001,1001,000Perkins 4008TAG2AMecc Alte ECO43-1M/450 HzView: TRX P MC 1100Request a Quote: TRX P MC 1100
TRX P ST 11001,1001,000Perkins 4008TAG2AStamford S6L1D-E450 HzView: TRX P ST 1100Request a Quote: TRX P ST 1100
TRX P TA 11001,1001,000Perkins 4008TAG2ATerex TA400-800N50 HzView: TRX P TA 1100Request a Quote: TRX P TA 1100
TRX SD TA 11001,1001,000SDEC 6WTAA35-G31Terex TA400-800N50 HzView: TRX SD TA 1100Request a Quote: TRX SD TA 1100
TRX BD MC 11001,1201,020Baudouin 12M26G1100/5Mecc Alte ECO43-1M/450 HzView: TRX BD MC 1100Request a Quote: TRX BD MC 1100
TRX BD ST 11001,1201,020Baudouin 12M26G1100/5Stamford S5L1D-D4150 HzView: TRX BD ST 1100Request a Quote: TRX BD ST 1100
TRX BD TA 11001,1201,020Baudouin 12M26G1100/5Terex TA400-800N50 HzView: TRX BD TA 1100Request a Quote: TRX BD TA 1100

Not sure how much power you need? Let’s calculate it together

Fuel consumption, tank, dimensions and weight

Values are taken from our product data. Dimension, weight and tank columns are for the Canopied (soundproof) version; fields without data are shown as "–".

ModelAt 50% load (L/h)At 75% load (L/h)At 100% load (L/h)Fuel tank (L)Dimensions (L × W × H) (mm)Weight (kg)
TRX BD MC 090090.8133.1173.71,8604500 × 2200 × 32008,200
TRX BD ST 090090.8133.1173.71,8604500 × 2200 × 32008,200
TRX BD TA 090090.8133.1173.71,8604500 × 2200 × 32008,200
TRX CU ST 0900851211611,3505276 × 2100 × 33507,905
TRX P LS 0900901301721,5745100 × 2085 × 34347,771
TRX P MC 0900901301721,5745100 × 2085 × 34347,771
TRX P ST 0900901301721,5745100 × 2085 × 34347,968
TRX P TA 0900901301721,5745100 × 2085 × 34347,968
TRX SD TA 0900841241631,8604500 × 2200 × 32008,500
TRX BD MC 1000100.8146.5195.52,1004900 × 2500 × 350010,350
TRX BD ST 1000100.8146.5195.52,1004900 × 2500 × 350010,350
TRX BD TA 1000100.8146.5195.52,1004900 × 2500 × 350010,350
TRX CU ST 10001041511981,3505276 × 2100 × 33509,650
TRX P LS 1000971421942,1755550 × 2200 × 34348,831
TRX P MC 1000971421942,1755550 × 2200 × 34349,318
TRX P ST 1000971421942,1755550 × 2200 × 34349,160
TRX P TA 1000971421942,1755550 × 2200 × 34349,160
TRX YC TA 1000101.6149200.32,0605800 × 2250 × 3480–
TRX SD TA 1010100.7144.9189.52,1004900 × 2500 × 350010,350
TRX CU LS 11001131612092,1004900 × 2500 × 350010,600
TRX CU MC 11001131612092,1004900 × 2500 × 350010,600
TRX CU ST 11001131612092,1004900 × 2500 × 350010,600
TRX CU TA 11001131612092,1004900 × 2500 × 350010,600
TRX P LS 11001111622152,1755550 × 2200 × 34349,318
TRX P MC 11001111622152,1755550 × 2200 × 34349,318
TRX P ST 11001111622152,1755550 × 2200 × 34349,323
TRX P TA 11001111622152,1755550 × 2200 × 34349,323
TRX SD TA 110092.9136.6188.11,7545276 × 2100 × 34009,023
TRX BD MC 1100106.6155.3207.11,4504800 × 1800 × 29808,102
TRX BD ST 1100106.6155.3207.11,4504800 × 1800 × 29808,107
TRX BD TA 1100106.6155.3207.11,4504800 × 1800 × 29808,107

What can a 1000 kVA generator supply?

At a power factor of 0.8, 1000 kVA corresponds to about 800 kW of active power. On a 400 V three-phase supply, the full-load current is about 1,443 A.

Generators in this power range are typically used for:

  • Factories and production plants
  • Hospitals, shopping centres and large commercial buildings
  • Server rooms and telecom centres
  • Large construction sites and infrastructure projects

These examples are general information; the same rating does not cover the same load at every site. Sizing must be based on the total power of the connected equipment, motor starting currents and how much runs at the same time.

To calculate the required rating from a list of equipment: Power Calculator

What determines the price of a 1000 kVA generator

Two generators of the same rating can differ in price depending on the equipment chosen. The main factors are:

  • Engine brand and model
  • Alternator brand and model
  • Enclosure: soundproof canopy or open type
  • Control panel and automatic transfer switch (ATS)
  • Fuel tank capacity
  • Delivery location and transport

A written price quote is prepared once you send us your power requirement and preferred equipment.

Get price and lead timeCall +90 216 634 34 06

Frequently asked questions

How many kW is a 1000 kVA generator?

At a power factor of 0.8, 1000 kVA equals 800 kW of active power (kW = kVA × 0.8). The models on this page have standby ratings of 720–896 kW.

How much fuel does a 1000 kVA generator use per hour?

According to manufacturer data, the models on this page use 121–162 litres per hour at 75% load. Consumption varies with load, engine and operating conditions; each model’s values are on its product page.

What does the price of a 1000 kVA generator depend on?

The price depends on the engine and alternator brand, the enclosure (canopy or open type), the control panel and ATS, the fuel tank capacity and the delivery location. A written price quote is prepared once you send us your power requirement and preferred equipment.

Request a quote for a 1000 kVA generator