This page lists 18 diesel generator models with standby ratings of 2500–2750 kVA (2000–2200 kW). Ratings listed: 2500 and 2750 kVA.

Get price and lead timeView models

Terex Diesel high-output canopied diesel generator

Request a quote

Tell us your power requirement, duty (standby or prime) and delivery location, and we will prepare a quote for your project.

Contact us directly

Call +90 216 634 34 06WhatsApp +90 533 582 26 50

Your request has been received. We will contact you as soon as possible.

Could not send. Please try again or call us. You can also reach us directly: WhatsApp +90 533 582 26 50 · info@terexdiesel.com

Too many submissions in a short time. Please try again in a few minutes.

Phone or email (one is enough)

Terms for sales outside Türkiye

  • Warranty outside Türkiye

    12 months or 1,000 operating hours for all engine brands.

  • Certificates

    ISO 9001 · CE · TSE-HYB

  • Export documents

    A commercial invoice and packing list are prepared; a certificate of origin and any other documents the buyer requires are issued on request.

Export Process and Payment

Key figures

Models
18
Standby power range
2,500–2,750 kVA
Engine brands
Perkins, Baudouin, Cummins
Fuel consumption (75% load)
331–381.3 L/h

Figures are calculated from the technical data of the models on this page; per-model values are on each product page.

Models rated 2500–2750 kVA standby

The table shows each model’s standby and prime ratings, engine and alternator; click a model name for full specifications. Use the compare button in the table to view models side by side.

Models rated 2500–2750 kVA standby
ModelStandby (kVA)Prime (kVA)EngineAlternatorFrequencyCompareView
TRX BD MC 25002,5002,250Baudouin 20M33G2500/5Mecc Alte ECO46-1.5L/450 HzView: TRX BD MC 2500Request a Quote: TRX BD MC 2500
TRX BD ST 25002,5002,250Baudouin 20M33G2500/5Stamford S7L1D-J50 HzView: TRX BD ST 2500Request a Quote: TRX BD ST 2500
TRX BD TA 25002,5002,250Baudouin 20M33G2500/5Terex TA500-1800N50 HzView: TRX BD TA 2500Request a Quote: TRX BD TA 2500
TRX CU LS 25002,5002,250Cummins QSK60G8Leroy-Somer LSA 52.3 S950 HzView: TRX CU LS 2500Request a Quote: TRX CU LS 2500
TRX CU MC 25002,5002,250Cummins QSK60G8Mecc Alte ECO46-1.5L/450 HzView: TRX CU MC 2500Request a Quote: TRX CU MC 2500
TRX CU ST 25002,5002,250Cummins QSK60G8Stamford S7L1D-H4-B50 HzView: TRX CU ST 2500Request a Quote: TRX CU ST 2500
TRX CU TA 25002,5002,250Cummins QSK60G8Terex TA500-1800N50 HzView: TRX CU TA 2500Request a Quote: TRX CU TA 2500
TRX P LS 25002,5002,250Perkins 4016-61TRG3Leroy-Somer LSA 52.3 S950 HzView: TRX P LS 2500Request a Quote: TRX P LS 2500
TRX P MC 25002,5002,250Perkins 4016-61TRG3Mecc Alte ECO46-1.5L/450 HzView: TRX P MC 2500Request a Quote: TRX P MC 2500
TRX P ST 25002,5002,250Perkins 4016-61TRG3Stamford S7L1D-J50 HzView: TRX P ST 2500Request a Quote: TRX P ST 2500
TRX P TA 25002,5002,250Perkins 4016-61TRG3Terex TA500-1800N50 HzView: TRX P TA 2500Request a Quote: TRX P TA 2500
TRX BD MC 27502,7502,500Baudouin 12M55G2750/5Mecc Alte ECO46-2L/450 HzView: TRX BD MC 2750Request a Quote: TRX BD MC 2750
TRX BD ST 27502,7502,500Baudouin 12M55G2750/5Stamford S7L1D-L50 HzView: TRX BD ST 2750Request a Quote: TRX BD ST 2750
TRX BD TA 27502,7502,500Baudouin 12M55G2750/5Terex TA550-2000N50 HzView: TRX BD TA 2750Request a Quote: TRX BD TA 2750
TRX CU LS 27502,7502,500Cummins QSK60G23Leroy-Somer LSA 54.3 S950 HzView: TRX CU LS 2750Request a Quote: TRX CU LS 2750
TRX CU MC 27502,7502,500Cummins QSK60G23Mecc Alte ECO46-2L/450 HzView: TRX CU MC 2750Request a Quote: TRX CU MC 2750
TRX CU ST 27502,7502,500Cummins QSK60G23Stamford PI73450 HzView: TRX CU ST 2750Request a Quote: TRX CU ST 2750
TRX CU TA 27502,7502,500Cummins QSK60G23Terex TA550-2000N50 HzView: TRX CU TA 2750Request a Quote: TRX CU TA 2750

Not sure how much power you need? Let’s calculate it together

Fuel consumption, tank, dimensions and weight

Values are taken from our product data. Dimension, weight and tank columns are for the Open type version; fields without data are shown as "–".

ModelAt 50% load (L/h)At 75% load (L/h)At 100% load (L/h)Fuel tank (L)Dimensions (L × W × H) (mm)Weight (kg)
TRX BD MC 2500240.5360.7466.42,3505150 × 2500 × 320014,900
TRX BD ST 2500240.5360.7466.42,3505150 × 2500 × 320014,900
TRX BD TA 2500240.5360.7466.42,3505150 × 2500 × 320014,900
TRX CU LS 2500–3314412,3505150 × 2500 × 320012,850
TRX CU MC 2500–3314412,3505150 × 2500 × 320012,850
TRX CU ST 2500–3314412,3505150 × 2500 × 320012,850
TRX CU TA 2500–3314412,3505150 × 2500 × 320012,850
TRX P LS 25002333555033,0006350 × 2400 × 302015,017
TRX P MC 25002333555033,0006350 × 2400 × 302015,017
TRX P ST 25002333555033,0006350 × 2400 × 302015,092
TRX P TA 25002333555033,0006350 × 2400 × 302015,092
TRX BD MC 2750263.3381.3513.6–––
TRX BD ST 2750263.3381.3513.6–––
TRX BD TA 2750263.3381.3513.6–––
TRX CU LS 2750–––2,3505150 × 2500 × 320013,850
TRX CU MC 2750–––2,3505150 × 2500 × 320013,850
TRX CU ST 2750–––2,3505150 × 2500 × 320013,850
TRX CU TA 2750–––2,3505150 × 2500 × 320013,850

What can a 2500 kVA generator supply?

At a power factor of 0.8, 2500 kVA corresponds to about 2,000 kW of active power. On a 400 V three-phase supply, the full-load current is about 3,608 A.

Generators in this power range are typically used for:

  • Large industrial plants
  • Hospital campuses and data centres
  • Mining and energy sites
  • Multi-generator systems running in parallel

These examples are general information; the same rating does not cover the same load at every site. Sizing must be based on the total power of the connected equipment, motor starting currents and how much runs at the same time.

To calculate the required rating from a list of equipment: Power Calculator

What determines the price of a 2500 kVA generator

Two generators of the same rating can differ in price depending on the equipment chosen. The main factors are:

  • Engine brand and model
  • Alternator brand and model
  • Enclosure: container or open type
  • Control panel and automatic transfer switch (ATS)
  • Fuel tank capacity
  • Delivery location and transport

A written price quote is prepared once you send us your power requirement and preferred equipment.

Get price and lead timeCall +90 216 634 34 06

One set or several sets in parallel?

In this power class the load can be supplied by one set or by several sets running in parallel through a synchronization panel. In a parallel system one set can be stopped for maintenance while the others carry the load, and at low load one set can be shut down. The choice depends on the load profile, the redundancy required and site conditions, and is made at the quotation stage.

Standby power is for backup during mains failures. Where there is no grid, or the set will run for long periods, size the set on its prime rating.

Canopy sets go up to 1,100 kVA; sets above 1,100 kVA are supplied in a container: Containerised Generators

Frequently asked questions

How many kW is a 2500 kVA generator?

At a power factor of 0.8, 2500 kVA equals 2000 kW of active power (kW = kVA × 0.8). The models on this page have standby ratings of 2000–2200 kW.

How much fuel does a 2500 kVA generator use per hour?

According to manufacturer data, the models on this page use 331–381.3 litres per hour at 75% load. Consumption varies with load, engine and operating conditions; each model’s values are on its product page.

What does the price of a 2500 kVA generator depend on?

The price depends on the engine and alternator brand, the enclosure (container or open type), the control panel and ATS, the fuel tank capacity and the delivery location. A written price quote is prepared once you send us your power requirement and preferred equipment.

Request a quote for a 2500 kVA generator

Tell us your power requirement, duty (standby or prime) and delivery location, and we will prepare a quote for your project.

Get price and lead time

Chat on WhatsApp

Download