Georgia – Dealer stock: 22–400 kVA canopy sets

A written technical specification (dealer stock) for 22–400 kVA canopy sets: we analysed the requirements and selected TRX P ST 0022 (Perkins 404A-22G1, 22 kVA standby / 20 kVA prime) with 5 alternative configurations, answered 10 points in a compliance table and prepared the documents listed below.

Country
Georgia
Application
Dealer stock
Power
22 kVA standby / 20 kVA prime · 50 Hz
Source of requirements
Written technical specification

Request a quote

Contact us directly

Call +90 216 634 34 06WhatsApp +90 533 582 26 50

We reply in English.

Your request has been received. We will contact you as soon as possible.

Could not send. Please try again or call us. You can also reach us directly: WhatsApp +90 533 582 26 50 · info@terexdiesel.com

Too many submissions in a short time. Please try again in a few minutes.

More details? Use the full request form

The request

Rating20 / 45 / 110 / 250 / 400 kVA standby
EnclosureSound-attenuated canopy
Fuel tank and autonomy8 h autonomy at 75 % load
Engine brandPerkins/Baudouin/Cummins (premium) plus SDEC/Yangdong option
Controller and communicationsAMF
StandardsISO 9001; CE; EN ISO 8528 test report
Other requirementsDatasheets; Certificate of origin; Manufacturer authorization letter

Our work

Requirement analysis · Model selection and sizing

  • Five sizes 20/45/110/250/400 kVA standby, canopy, AMF controller, 8 hours autonomy at 75 percent load
  • Perkins premium table plus economy option with SDEC (from 130 kVA) and Quartz below that
  • Standards and documents requested: ISO 9001, CE, EN ISO 8528 test report, datasheets, origin certificate, manufacturer authorization

Point-by-point compliance table

ItemRequiredOur proposalAssessment
Engine brandPerkins/Baudouin/Cummins (premium) plus SDEC/Yangdong optionPerkins 404A-22G1Complies
EnclosureSound-attenuated canopyCanopy, 1950 × 900 × 1337 mmComplies
20 kVA–22 kVA standby modelDeviation / to be confirmed
45 kVA–50 kVA standby modelDeviation / to be confirmed
AMF–Datakom AMF controllerComplies
CE certificate–AttachedComplies
ISO 9001 and EN ISO 8528 test reports––Deviation / to be confirmed
Datasheets, certificate of origin, manufacturer authorization letter–Datasheets attached; origin certificate and authorization letter per tender within 48 hoursWith option
ATS–Available on requestWith option
Georgian import duties and taxes–Not includedBuyer / local scope

Options identified and priced

  • SDEC / Quartz economy option
  • Cummins and Baudouin on request
  • ATS on request

Documents prepared · Offer package

  • Commercial offer (line-item structure; prices not published here)
  • Model datasheet
  • CE certificate

Proposed solution

TRX P ST 0022

Standby power22 kVA / 17.6 kW
Prime power20 kVA / 16 kW
Voltage · Frequency · Speed230/400 V · 50 Hz · 1,500 rpm
EnginePerkins 404A-22G1 · 2.216 L
AlternatorStamford S0L2-G1 · AVR SX460 · IP23/H
Fuel consumption · At 75% load4 L/h
Fuel consumption · At 100% load5.3 L/h
Fuel tank (Canopied (soundproof))82 L
Dimensions (L × W × H) (Canopied (soundproof))1,950 × 900 × 1,337 mm · 627 kg
Dimensions (L × W × H) (Open type)1,600 × 900 × 1,145 mm · 456 kg

TRX P ST 0050

Standby power50 kVA / 40 kW
Prime power45 kVA / 36 kW
Voltage · Frequency · Speed230/400 V · 50 Hz · 1,500 rpm
EnginePerkins 1103A-33TG1 · 3.3 L
AlternatorStamford S1L2-N · AVR SX460 · IP23/H
Fuel consumption · At 75% load8.2 L/h
Fuel consumption · At 100% load10.7 L/h
Fuel tank (Canopied (soundproof))101 L
Dimensions (L × W × H) (Canopied (soundproof))2,300 × 1,000 × 1,545 mm · 998 kg
Dimensions (L × W × H) (Open type)1,900 × 1,000 × 1,396 mm · 788 kg

TRX P ST 0110

Standby power110 kVA / 88 kW
Prime power100 kVA / 80 kW
Voltage · Frequency · Speed230/400 V · 50 Hz · 1,500 rpm
EnginePerkins 1104C-44TAG2 · 4.4 L
AlternatorStamford UCI274C · AVR SX460 · IP23/H
Fuel consumption · At 75% load20.2 L/h
Fuel consumption · At 100% load26.9 L/h
Fuel tank (Canopied (soundproof))139 L
Dimensions (L × W × H) (Canopied (soundproof))2,600 × 1,000 × 1,570 mm · 1,352 kg
Dimensions (L × W × H) (Open type)2,200 × 1,000 × 1,385 mm · 1,127 kg

TRX P ST 0250

Standby power250 kVA / 200 kW
Prime power230 kVA / 184 kW
Voltage · Frequency · Speed230/400 V · 50 Hz · 1,500 rpm
EnginePerkins 1206A-E70TTAG2 · 7.01 L
AlternatorStamford UCDI274K · AVR SX460 · IP23/H
Fuel consumption · At 75% load38 L/h
Fuel consumption · At 100% load51 L/h
Fuel tank (Canopied (soundproof))415 L
Dimensions (L × W × H) (Canopied (soundproof))3,600 × 1,200 × 2,288 mm · 2,269 kg
Dimensions (L × W × H) (Open type)2,850 × 1,200 × 1,920 mm · 1,877 kg

TRX P ST 0400

Standby power400 kVA / 320 kW
Prime power350 kVA / 280 kW
Voltage · Frequency · Speed230/400 V · 50 Hz · 1,500 rpm
EnginePerkins 2206A-E13TAG2 · 12.5 L
AlternatorStamford S4L1D-E · AVR AS440 · IP23/H
Fuel consumption · At 75% load54 L/h
Fuel consumption · At 100% load71 L/h
Fuel tank (Canopied (soundproof))819 L
Dimensions (L × W × H) (Canopied (soundproof))4,050 × 1,600 × 2,615 mm · 3,986 kg
Dimensions (L × W × H) (Open type)3,600 × 1,500 × 2,116 mm · 3,332 kg

Values are taken from the model’s datasheet; the full datasheet and catalogue page are on the model page.

Offered configuration

  • Controller: Datakom (AMF)
  • 400/230 V 50 Hz 3-phase 1500 rpm
  • Base fuel tank

Alternative configurations

Packing, shipping and export documents

  • Transport: road transport by truck.
  • Canopy sets are stretch-wrapped with edge protection; loose parts travel in crates or on pallets.
  • Export documents: commercial invoice, packing list, certificate of origin, factory test report.

Customer, tender and site names are withheld; only the country is shown. Prices and commercial terms are not published. Customer documents are not shared; requirements are summarised in our own words.

How we work with your specification

  1. Send the specification, datasheet form or list of needs (PDF, Excel, Word or a message).
  2. We reply on the same working day and ask about missing or unclear points.
  3. We size the power (prime/standby), voltage, frequency, ambient conditions and autonomy, select the model and prepare a point-by-point compliance table. Deviations and options are stated openly.
  4. We send the package — offer, datasheet, catalogue pages and any forms requested; for standard configurations within 24 hours.

Send your specification

No specification yet? Download our specification template for a hospital, school or data centre (Word, PDF)

Chat on WhatsApp

Download