Serbia – 38–77 kVA canopy sets

A request for 38–77 kVA canopy sets: we analysed the requirements and selected TRX QZ TA 0038 (Quartz Q490ZD, 38 kVA standby / 34.2 kVA prime), answered 3 points in a compliance table and prepared the documents listed below.

Country
Serbia
Power
38 kVA standby / 34.2 kVA prime · 50 Hz
Quantity
Several sets
Source of requirements
Requirements sent by message or e-mail

Request a quote

Contact us directly

Call +90 216 634 34 06WhatsApp +90 533 582 26 50

We reply in English.

Your request has been received. We will contact you as soon as possible.

Could not send. Please try again or call us. You can also reach us directly: WhatsApp +90 533 582 26 50 · info@terexdiesel.com

Too many submissions in a short time. Please try again in a few minutes.

More details? Use the full request form

The request

Rating31 / 50 / 70 kVA
EnclosureSound-attenuated canopy

Our work

Requirement analysis · Model selection and sizing

  • Three Quartz models matched to 31/50/70 kVA

Point-by-point compliance table

ItemRequiredOur proposalAssessment
EnclosureSound-attenuated canopyCanopy, 2200 × 1000 × 1550 mmComplies
Installation protection (leakage protection, breaker, transfer system)–Customer installation responsibility per offerBuyer / local scope
Engine oil, antifreeze, anti-vibration mounts–IncludedComplies

Documents prepared · Offer package

  • Commercial offer (line-item structure; prices not published here)
  • Catalogue pages
  • Factory load-test report (sample)
  • Catalogue pagesCatalogue pages
  • Factory load-test report (sample)Factory load-test report (sample)

Proposed solution

TRX QZ TA 0038

Standby power38 kVA / 30.4 kW
Prime power34.2 kVA / 27.36 kW
Voltage · Frequency · Speed230/400 V · 50 Hz · 1,500 rpm
EngineQuartz Q490ZD · 2.545 L
AlternatorTerex TA180-24N2 · AVR SX460 · IP23/H
Fuel consumption · At 75% load6.6 L/h
Fuel consumption · At 100% load7.2 L/h
Fuel tank (Canopied (soundproof))125 L
Dimensions (L × W × H) (Canopied (soundproof))2,200 × 1,000 × 1,550 mm · 1,045 kg
Dimensions (L × W × H) (Open type)1,500 × 1,000 × 1,350 mm · 895 kg

TRX QZ TA 0058

Standby power58 kVA / 46.4 kW
Prime power52.2 kVA / 41.76 kW
Voltage · Frequency · Speed230/400 V · 50 Hz · 1,500 rpm
EngineQuartz Q4105D · 4.33 L
AlternatorTerex TA180-36N2 · AVR SX460 · IP23/H
Fuel consumption · At 75% load8 L/h
Fuel consumption · At 100% load10.9 L/h
Fuel tank (Canopied (soundproof))220 L
Dimensions (L × W × H) (Canopied (soundproof))2,440 × 1,000 × 1,860 mm · 1,310 kg
Dimensions (L × W × H) (Open type)1,900 × 900 × 1,610 mm · 1,160 kg

TRX QZ TA 0077

Standby power77 kVA / 61.6 kW
Prime power69.3 kVA / 55.44 kW
Voltage · Frequency · Speed230/400 V · 50 Hz · 1,500 rpm
EngineQuartz Q4105ZD · 4.33 L
AlternatorTerex TA180-40N2 · AVR SX460 · IP23/H
Fuel consumption · At 75% load10.9 L/h
Fuel consumption · At 100% load14.7 L/h
Fuel tank (Canopied (soundproof))125 L
Dimensions (L × W × H) (Canopied (soundproof))2,350 × 1,000 × 1,550 mm · 1,450 kg
Dimensions (L × W × H) (Open type)1,500 × 1,000 × 1,350 mm · 1,250 kg

Values are taken from the model’s datasheet; the full datasheet and catalogue page are on the model page.

Offered configuration

  • Controller: Deep Sea DSE
  • 38/34.2, 58/52.2, 77/69.3 kVA standby/prime
  • Engines Q490ZD / Q4105D / Q4105ZD

Packing, shipping and export documents

  • Transport: ex works Istanbul, with transport arranged on request.
  • Canopy sets are stretch-wrapped with edge protection; loose parts travel in crates or on pallets.
  • Export documents: commercial invoice, packing list, certificate of origin, factory test report.

Customer, tender and site names are withheld; only the country is shown. Prices and commercial terms are not published. Customer documents are not shared; requirements are summarised in our own words.

How we work with your specification

  1. Send the specification, datasheet form or list of needs (PDF, Excel, Word or a message).
  2. We reply on the same working day and ask about missing or unclear points.
  3. We size the power (prime/standby), voltage, frequency, ambient conditions and autonomy, select the model and prepare a point-by-point compliance table. Deviations and options are stated openly.
  4. We send the package — offer, datasheet, catalogue pages and any forms requested; for standard configurations within 24 hours.

Send your specification

No specification yet? Download our specification template for a hospital, school or data centre (Word, PDF)

Chat on WhatsApp

Download