Poland – 105–660 kVA canopy sets

A written technical specification for 105–660 kVA canopy sets: we analysed the requirements and selected TRX QZ TA 0105 (Quartz Q4105AZLD, 105 kVA standby / 94.5 kVA prime) with 1 alternative configuration, answered 3 points in a compliance table and prepared the documents listed below.

Country
Poland
Power
105 kVA standby / 94.5 kVA prime · 50 Hz
Quantity
Series supply (many sets)
Source of requirements
Written technical specification

Request a quote

Contact us directly

Call +90 216 634 34 06WhatsApp +90 533 582 26 50

We reply in English.

Your request has been received. We will contact you as soon as possible.

Could not send. Please try again or call us. You can also reach us directly: WhatsApp +90 533 582 26 50 · info@terexdiesel.com

Too many submissions in a short time. Please try again in a few minutes.

More details? Use the full request form

The request

Rating65–640 (5 PRP ranges: 65–99 ×90, 100–199 ×60, 200–350 ×60, 351–599 ×60, 600–640 ×10) kVA prime
Site conditionsMin -30 °C
Fuel tank and autonomyAutonomy at 75 % load by power range: 20 / 10 / 9 / 8 / 7 h
Other requirementsMax weight per range (1.8 t / 3.5 t / 6 t / 12 t / 25 t); Overall dimensions within 6.1 × 2.5 × 2.99 m; Engine block heater for –30 °C; Base tank sized for required runtime; EU funding labels; Test run and fluid drain before delivery; Partial deliveries accepted
EmissionEU Stage II

Our work

Requirement analysis · Model selection and sizing

  • Each PRP range mapped to one model by prime rating
  • Required runtime at 75% load checked against base-tank capacity
  • Canopy dimensions checked against overall size limit
  • Stage II engines selected

Point-by-point compliance table

ItemRequiredOur proposalAssessment
Operation down to –30 °C–Engine block heaterWith option
Runtime at 75% load–Enlarged spill-contained base tankWith option
EU funding labels, test run with fluid drain–Quoted on configuration confirmationWith option

Options identified and priced

  • Engine block heater
  • Enlarged base-frame fuel tank
  • EU funding labels
  • Test run with fluid drain
  • Truck transport per batch

Documents prepared · Offer package

  • Commercial offer (line-item structure; prices not published here)
  • Model datasheet
  • CE certificate
  • Company profile
  • Factory load-test report (sample)
  • Start-up and handover form
  • Maintenance and service forms
  • Operating and maintenance manual
  • Model datasheetModel datasheet
  • Factory load-test report (sample)Factory load-test report (sample)
  • Start-up and handover formStart-up and handover form

Proposed solution

TRX QZ TA 0105

Standby power105 kVA / 84 kW
Prime power94.5 kVA / 75.6 kW
Voltage · Frequency · Speed230/400 V · 50 Hz · 1,500 rpm
EngineQuartz Q4105AZLD
AlternatorTerex TA225-80N · AVR SX460 · IP23/H
Fuel tank (Canopied (soundproof))125 L
Dimensions (L × W × H) (Canopied (soundproof))2,350 × 1,000 × 1,550 mm · 1,800 kg
Dimensions (L × W × H) (Open type)1,500 × 1,000 × 1,350 mm · 1,600 kg

TRX QZ TA 0155

Standby power155 kVA / 124 kW
Prime power139.5 kVA / 111.6 kW
Voltage · Frequency · Speed230/400 V · 50 Hz · 1,500 rpm
EngineQuartz Q6105AZLD · 6.75 L
AlternatorTerex TA225-120N · AVR SX460 · IP23/H
Fuel tank (Canopied (soundproof))265 L
Dimensions (L × W × H) (Canopied (soundproof))3,000 × 1,100 × 1,850 mm · 2,135 kg
Dimensions (L × W × H) (Open type)2,100 × 1,100 × 1,650 mm · 1,835 kg

TRX SD TA 0260

Standby power260 kVA / 208 kW
Prime power236 kVA / 188.8 kW
Voltage · Frequency · Speed230/400 V · 50 Hz · 1,500 rpm
EngineSDEC SC9D310D2
AlternatorTerex TA280-220N · AVR SX460 · IP23/H
Fuel consumption · At 75% load38.2 L/h
Fuel consumption · At 100% load50.6 L/h
Fuel tank (Canopied (soundproof))415 L
Dimensions (L × W × H) (Canopied (soundproof))3,600 × 1,200 × 2,288 mm · 2,271 kg
Dimensions (L × W × H) (Open type)2,850 × 1,200 × 1,895 mm · 1,889 kg

TRX SD TA 0440

Standby power440 kVA / 352 kW
Prime power400 kVA / 320 kW
Voltage · Frequency · Speed230/400 V · 50 Hz · 1,500 rpm
EngineSDEC SC15G500D2 · 14.16 L
AlternatorTerex TA315-320N · AVR AS440 · IP23/H
Fuel consumption · At 75% load59.8 L/h
Fuel consumption · At 100% load81.2 L/h
Fuel tank (Canopied (soundproof))846 L
Dimensions (L × W × H) (Canopied (soundproof))3,750 × 1,400 × 2,646 mm · 3,593 kg
Dimensions (L × W × H) (Open type)3,150 × 1,400 × 2,400 mm · 3,093 kg

TRX SD TA 0660

Standby power660 kVA / 528 kW
Prime power600 kVA / 480 kW
Voltage · Frequency · Speed230/400 V · 50 Hz · 1,500 rpm
EngineSDEC SC27G755D2 · 26.6 L
AlternatorTerex TA355-470N · AVR AS440 · IP23/H
Fuel consumption · At 75% load95.3 L/h
Fuel consumption · At 100% load126 L/h
Fuel tank (Canopied (soundproof))1,263 L
Dimensions (L × W × H) (Canopied (soundproof))4,200 × 1,816 × 2,806 mm · 5,341 kg
Dimensions (L × W × H) (Open type)3,750 × 1,700 × 2,350 mm · 4,513 kg

Values are taken from the model’s datasheet; the full datasheet and catalogue page are on the model page.

Offered configuration

  • Controller: Deep Sea DSE
  • 105/94.5, 155/139.5, 260/236, 440/400, 660/600 kVA standby/PRP
  • 50 Hz 400/230 V 1500 rpm
  • Electronic governor
  • Stage II liquid-cooled engines
  • Base-frame fuel tank
  • 4-pole main circuit breaker

Alternative configurations

Packing, shipping and export documents

  • Transport: road transport by truck.
  • Canopy sets are stretch-wrapped with edge protection; loose parts travel in crates or on pallets.
  • Export documents: commercial invoice, packing list, certificate of origin, A.TR movement certificate for EU customs clearance, factory test report.

Customer, tender and site names are withheld; only the country is shown. Prices and commercial terms are not published. Customer documents are not shared; requirements are summarised in our own words.

How we work with your specification

  1. Send the specification, datasheet form or list of needs (PDF, Excel, Word or a message).
  2. We reply on the same working day and ask about missing or unclear points.
  3. We size the power (prime/standby), voltage, frequency, ambient conditions and autonomy, select the model and prepare a point-by-point compliance table. Deviations and options are stated openly.
  4. We send the package — offer, datasheet, catalogue pages and any forms requested; for standard configurations within 24 hours.

Send your specification

No specification yet? Download our specification template for a hospital, school or data centre (Word, PDF)

Chat on WhatsApp

Download