Albania – 25–110 kVA canopy sets

A request for 25–110 kVA canopy sets: we analysed the requirements and selected TRX BD TA 0025 (Baudouin 4M06G4D0/S, 25 kVA standby / 23 kVA prime), answered 6 points in a compliance table and prepared the documents listed below.

Country
Albania
Power
25 kVA standby / 23 kVA prime · 50 Hz
Quantity
Several sets
Source of requirements
Requirements sent by message or e-mail

Request a quote

Contact us directly

Call +90 216 634 34 06WhatsApp +90 533 582 26 50

We reply in English.

Your request has been received. We will contact you as soon as possible.

Could not send. Please try again or call us. You can also reach us directly: WhatsApp +90 533 582 26 50 · info@terexdiesel.com

Too many submissions in a short time. Please try again in a few minutes.

More details? Use the full request form

The request

Rating25 / 44 / 70 / 110 kVA
EnclosureSound-attenuated canopy
Automatic transfer switchYes
Engine brandBaudouin
Other requirementsOutput circuit breaker

Our work

Requirement analysis · Model selection and sizing

  • Four sizes requested (25/44/70/110 kVA); 70 kVA matched to the 72 kVA Baudouin model
  • Baudouin engines with Terex alternators and Deep Sea DSE controller; canopy, output breaker and ATS requested

Point-by-point compliance table

ItemRequiredOur proposalAssessment
Engine brandBaudouinBaudouin 4M06G4D0/SComplies
EnclosureSound-attenuated canopyCanopy, 1950 × 900 × 1337 mmComplies
70 kVA–72 kVA standby model offeredDeviation / to be confirmed
Canopy–Sound-insulated canopy setsComplies
ATS per set–ATS 100 A / 100 A / 250 A / 250 AComplies
Output circuit breaker––Complies

Options identified and priced

  • ATS per set

Documents prepared · Offer package

  • Commercial offer (line-item structure; prices not published here)
  • Catalogue pages
  • Factory load-test report (sample)
  • Warranty terms document
  • Start-up and handover form
  • Maintenance and service forms
  • Operating and maintenance manual
  • Alternator datasheet
  • Controller datasheet
  • Factory load-test report (sample)Factory load-test report (sample)
  • Warranty terms documentWarranty terms document
  • Start-up and handover formStart-up and handover form
  • Offer package 72 pages, Albanian offer: offer, 4 model catalogue blocks, alternator datasheets, 4 sample factory test reports, 7 service document types x 4 models (28 pages)

Proposed solution

TRX BD TA 0025

Standby power25 kVA / 20 kW
Prime power23 kVA / 18.4 kW
Voltage · Frequency · Speed230/400 V · 50 Hz · 1,500 rpm
EngineBaudouin 4M06G4D0/S · 2.3 L
AlternatorTerex TA180-24N2 · AVR SX460 · IP23/H
Fuel consumption · At 75% load4.5 L/h
Fuel consumption · At 100% load6.1 L/h
Fuel tank (Canopied (soundproof))82 L
Dimensions (L × W × H) (Canopied (soundproof))1,950 × 900 × 1,337 mm · 689 kg
Dimensions (L × W × H) (Open type)1,600 × 900 × 1,215 mm · 518 kg

TRX BD TA 0044

Standby power44 kVA / 35.2 kW
Prime power40 kVA / 32 kW
Voltage · Frequency · Speed230/400 V · 50 Hz · 1,500 rpm
EngineBaudouin 4M06G8D0/S · 2.3 L
AlternatorTerex TA180-34N2 · AVR SX460 · IP23/H
Fuel consumption · At 75% load7 L/h
Fuel consumption · At 100% load9.5 L/h
Fuel tank (Canopied (soundproof))101 L
Dimensions (L × W × H) (Canopied (soundproof))2,300 × 1,000 × 1,545 mm · 870 kg
Dimensions (L × W × H) (Open type)1,900 × 1,000 × 1,215 mm · 600 kg

TRX BD TA 0072

Standby power72 kVA / 57.6 kW
Prime power65 kVA / 52 kW
Voltage · Frequency · Speed230/400 V · 50 Hz · 1,500 rpm
EngineBaudouin 4M10G2D0/S · 4.087 L
AlternatorTerex TA180-40N2 · AVR SX460 · IP23/H
Fuel consumption · At 75% load11 L/h
Fuel consumption · At 100% load15 L/h
Fuel tank (Canopied (soundproof))139 L
Dimensions (L × W × H) (Canopied (soundproof))2,600 × 1,000 × 1,570 mm · 1,119 kg
Dimensions (L × W × H) (Open type)2,200 × 1,000 × 1,476 mm · 894 kg

TRX BD TA 0110

Standby power110 kVA / 88 kW
Prime power100 kVA / 80 kW
Voltage · Frequency · Speed230/400 V · 50 Hz · 1,500 rpm
EngineBaudouin 4M10G6D0/S · 4.087 L
AlternatorTerex TA225-80N · AVR SX460 · IP23/H
Fuel consumption · At 75% load16 L/h
Fuel consumption · At 100% load21.3 L/h
Fuel tank (Canopied (soundproof))139 L
Dimensions (L × W × H) (Canopied (soundproof))2,600 × 1,000 × 1,570 mm · 1,350 kg
Dimensions (L × W × H) (Open type)2,200 × 1,000 × 1,476 mm · 1,130 kg

Values are taken from the model’s datasheet; the full datasheet and catalogue page are on the model page.

Offered configuration

  • Controller: Deep Sea DSE

Packing, shipping and export documents

  • Transport: ex works Istanbul, with transport arranged on request.
  • Canopy sets are stretch-wrapped with edge protection; loose parts travel in crates or on pallets.
  • Export documents: commercial invoice, packing list, certificate of origin, factory test report.

Customer, tender and site names are withheld; only the country is shown. Prices and commercial terms are not published. Customer documents are not shared; requirements are summarised in our own words.

How we work with your specification

  1. Send the specification, datasheet form or list of needs (PDF, Excel, Word or a message).
  2. We reply on the same working day and ask about missing or unclear points.
  3. We size the power (prime/standby), voltage, frequency, ambient conditions and autonomy, select the model and prepare a point-by-point compliance table. Deviations and options are stated openly.
  4. We send the package — offer, datasheet, catalogue pages and any forms requested; for standard configurations within 24 hours.

Send your specification

No specification yet? Download our specification template for a hospital, school or data centre (Word, PDF)

Chat on WhatsApp

Download