Albaniya – 25–110 kVA kabinali generator agregatlari
25–110 kVA kabinali generator agregatlari uchun so‘rov: talablarni tahlil qildik, TRX BD TA 0025 (Baudouin 4M06G4D0/S, 25 kVA zaxira / 23 kVA asosiy quvvat) modelini tanladik, muvofiqlik jadvalida 6 ta bandga javob berdik va quyida keltirilgan hujjatlarni tayyorladik.
- Davlat
- Albaniya
- Quvvat
- 25 kVA standby / 23 kVA prime · 50 Hz
- Soni
- Bir nechta dona
- Talablar manbai
- Talablar xabar yoki e-pochta orqali yuborilgan
Taklif va ma’lumot so‘rovi
Biz bilan bevosita bog‘laning
Qo‘ng‘iroq +90 216 634 34 06WhatsApp +90 533 582 26 50
O‘zbek tilida javob beramiz.
So‘rov
| Quvvat | 25 / 44 / 70 / 110 kVA |
|---|---|
| Korpus | Shovqin pasaytiruvchi kabina |
| Avtomatik o‘tkazish kaliti (ATS) | Ha |
| Dvigatel markasi | Baudouin |
| Boshqa talablar | Chiqish avtomatik o‘chirgichi |
Bajargan ishimiz
Talablar tahlili · Model tanlash va quvvatni hisoblash
- To‘rtta o‘lcham so‘raldi (25/44/70/110 kVA); 70 kVA uchun 72 kVA Baudouin modeli moslashtirildi
- Terex alternatorlari va Deep Sea DSE kontrolleri bilan Baudouin dvigatellari; kabina, chiqish avtomatik o‘chirgichi va ATS so‘raldi
Band-band muvofiqlik jadvali
| Band | Talab | Taklifimiz | Baholash |
|---|---|---|---|
| Dvigatel markasi | Baudouin | Baudouin 4M06G4D0/S | Mos keladi |
| Korpus | Shovqin pasaytiruvchi kabina | Kabina, 1950 × 900 × 1337 mm | Mos keladi |
| 70 kVA | – | 72 kVA zaxira quvvatli model taklif qilindi | Chetlanish / tasdiq talab etiladi |
| Kabina | – | Shovqin izolyatsiyali kabinali agregatlar | Mos keladi |
| Har bir agregat uchun ATS | – | ATS 100 A / 100 A / 250 A / 250 A | Mos keladi |
| Chiqish avtomatik o‘chirgichi | – | – | Mos keladi |
Aniqlangan va narxlangan opsiyalar
- Har bir agregat uchun ATS
Tayyorlangan hujjatlar · Taklif paketi
- Tijorat taklifi (bandlar tuzilmasi; narxlar bu yerda e’lon qilinmaydi)
- Katalog sahifalari
- Zavod yuklama sinovi hisoboti (namuna)
- Kafolat shartlari hujjati
- Birinchi ishga tushirish va topshirish shakli
- Texnik xizmat va servis shakllari
- Foydalanish va texnik xizmat qo‘llanmasi
- Alternator texnik varag‘i
- Kontroller texnik varag‘i
Zavod yuklama sinovi hisoboti (namuna)
Kafolat shartlari hujjati
Birinchi ishga tushirish va topshirish shakli
- Taklif paketi 72 sahifa, alban tilidagi taklif: taklif, 4 ta model bo‘yicha katalog bloklari, alternator texnik ma’lumotlar varaqlari, 4 ta namunaviy zavod sinov hisoboti, 4 ta model uchun 7 turdagi servis hujjati (28 sahifa)
Taklif etilgan yechim
TRX BD TA 0025
| Zaxira quvvati (Standby) | 25 kVA / 20 kW |
|---|---|
| Asosiy quvvat (Prime) | 23 kVA / 18,4 kW |
| Kuchlanish · Chastota · Aylanish tezligi | 230/400 V · 50 Hz · 1 500 ayl/daq |
| Dvigatel | Baudouin 4M06G4D0/S · 2,3 L |
| Alternator | Terex TA180-24N2 · AVR SX460 · IP23/H |
| Yoqilg‘i sarfi · 75% yuklamada | 4,5 L/soat |
| Yoqilg‘i sarfi · 100% yuklamada | 6,1 L/soat |
| Yoqilg‘i baki (Kabinali (shovqin izolyatsiyali)) | 82 L |
| O‘lchamlar (U × E × B) (Kabinali (shovqin izolyatsiyali)) | 1 950 × 900 × 1 337 mm · 689 kg |
| O‘lchamlar (U × E × B) (Ochiq turdagi) | 1 600 × 900 × 1 215 mm · 518 kg |
TRX BD TA 0044
| Zaxira quvvati (Standby) | 44 kVA / 35,2 kW |
|---|---|
| Asosiy quvvat (Prime) | 40 kVA / 32 kW |
| Kuchlanish · Chastota · Aylanish tezligi | 230/400 V · 50 Hz · 1 500 ayl/daq |
| Dvigatel | Baudouin 4M06G8D0/S · 2,3 L |
| Alternator | Terex TA180-34N2 · AVR SX460 · IP23/H |
| Yoqilg‘i sarfi · 75% yuklamada | 7 L/soat |
| Yoqilg‘i sarfi · 100% yuklamada | 9,5 L/soat |
| Yoqilg‘i baki (Kabinali (shovqin izolyatsiyali)) | 101 L |
| O‘lchamlar (U × E × B) (Kabinali (shovqin izolyatsiyali)) | 2 300 × 1 000 × 1 545 mm · 870 kg |
| O‘lchamlar (U × E × B) (Ochiq turdagi) | 1 900 × 1 000 × 1 215 mm · 600 kg |
TRX BD TA 0072
| Zaxira quvvati (Standby) | 72 kVA / 57,6 kW |
|---|---|
| Asosiy quvvat (Prime) | 65 kVA / 52 kW |
| Kuchlanish · Chastota · Aylanish tezligi | 230/400 V · 50 Hz · 1 500 ayl/daq |
| Dvigatel | Baudouin 4M10G2D0/S · 4,087 L |
| Alternator | Terex TA180-40N2 · AVR SX460 · IP23/H |
| Yoqilg‘i sarfi · 75% yuklamada | 11 L/soat |
| Yoqilg‘i sarfi · 100% yuklamada | 15 L/soat |
| Yoqilg‘i baki (Kabinali (shovqin izolyatsiyali)) | 139 L |
| O‘lchamlar (U × E × B) (Kabinali (shovqin izolyatsiyali)) | 2 600 × 1 000 × 1 570 mm · 1 119 kg |
| O‘lchamlar (U × E × B) (Ochiq turdagi) | 2 200 × 1 000 × 1 476 mm · 894 kg |
TRX BD TA 0110
| Zaxira quvvati (Standby) | 110 kVA / 88 kW |
|---|---|
| Asosiy quvvat (Prime) | 100 kVA / 80 kW |
| Kuchlanish · Chastota · Aylanish tezligi | 230/400 V · 50 Hz · 1 500 ayl/daq |
| Dvigatel | Baudouin 4M10G6D0/S · 4,087 L |
| Alternator | Terex TA225-80N · AVR SX460 · IP23/H |
| Yoqilg‘i sarfi · 75% yuklamada | 16 L/soat |
| Yoqilg‘i sarfi · 100% yuklamada | 21,3 L/soat |
| Yoqilg‘i baki (Kabinali (shovqin izolyatsiyali)) | 139 L |
| O‘lchamlar (U × E × B) (Kabinali (shovqin izolyatsiyali)) | 2 600 × 1 000 × 1 570 mm · 1 350 kg |
| O‘lchamlar (U × E × B) (Ochiq turdagi) | 2 200 × 1 000 × 1 476 mm · 1 130 kg |
Qiymatlar modelning texnik varag‘idan olingan; to‘liq varaq va katalog sahifasi model sahifasida.
Taklif etilgan konfiguratsiya
- Kontroller: Deep Sea DSE
Qadoqlash, jo‘natish va eksport hujjatlari
- Transport: Istanbulda zavoddan topshirish (ex works); tashish so‘rov bo‘yicha tashkil etiladi.
- Kabinali agregatlar chet himoyalari bilan strech-plyonkaga o‘raladi; alohida qismlar yashiklarda yoki palletlarda tashiladi.
- Eksport hujjatlari: tijorat hisob-fakturasi, qadoqlash varag‘i, kelib chiqish sertifikati, zavod sinov hisoboti.
Mijoz, tender va obyekt nomlari ko‘rsatilmaydi; faqat davlat yoziladi. Narxlar va tijorat shartlari e’lon qilinmaydi. Mijoz hujjatlari ulashilmaydi; talablar o‘z so‘zlarimiz bilan qisqacha bayon qilingan.
Texnik topshirig‘ingiz bilan qanday ishlaymiz
- Texnik topshiriq, texnik varaq shakli yoki ehtiyojlar ro‘yxatini yuboring (PDF, Excel, Word yoki xabar).
- Shu ish kunida javob beramiz va yetishmayotgan yoki noaniq bandlarni so‘raymiz.
- Quvvat (prime/standby), kuchlanish, chastota, muhit sharoitlari va avtonomiyani hisoblaymiz, modelni tanlaymiz va band-band muvofiqlik jadvalini tayyorlaymiz. Chetlanishlar va opsiyalar ochiq yoziladi.
- Paketni yuboramiz: taklif, texnik varaq, katalog sahifalari va so‘ralgan shakllar; standart konfiguratsiyalar uchun 24 soat ichida.