Uzbekistan – Telecom network sites: 20 kVA prime / 22 kVA standby canopy sets

A written technical specification (telecom network sites) for 20 kVA prime / 22 kVA standby canopy sets: we analysed the requirements and selected TRX QZ TA 0025 (Quartz Q490, 25 kVA standby / 22.5 kVA prime), answered 11 points in a compliance table and prepared the documents listed below.

Country
Uzbekistan
Application
Telecom network sites
Power
25 kVA standby / 22.5 kVA prime · 50 Hz
Quantity
Series supply (many sets)
Source of requirements
Written technical specification

Request a quote

Contact us directly

Call +90 216 634 34 06WhatsApp +90 533 582 26 50

We reply in English.

Your request has been received. We will contact you as soon as possible.

Could not send. Please try again or call us. You can also reach us directly: WhatsApp +90 533 582 26 50 · info@terexdiesel.com

Too many submissions in a short time. Please try again in a few minutes.

More details? Use the full request form

The request

Rating20 kVA prime / 22 kVA standby
Electrical400/230 V, 50 Hz, 1500 rpm
Site conditionsMax 50 °C, min -25 °C
Noise63 dB(A)
EnclosureSound-attenuated canopy
Fuel tank and autonomy250 L tank
Automatic transfer switchYes
Engine4 cylinders in-line; 4-stroke; Liquid cooled; Coolant heater; 3 start attempts
AlternatorSynchronous brushless with AVR; IP23; Class H; 1 or 3 phases
Controller and communicationsMains and generator V/A measurement; 3 configurable analog inputs; 7/7 binary inputs/outputs; Event log 400; Engine hour meter; Built-in web server; GSM/GPRS internet connection; SMS control
Other requirementsStandby min 17.6 kW / 22 kVA; Fuel tank heater; Built-in 12 V fuel transfer pump; Fuel filter with water separator; Check valve; 220 V mains battery charger, 12 V system; Low-noise silencers; Spare parts availability min 5 years

Our work

Requirement analysis · Model selection and sizing

  • ≥16 kW / ≥20 kVA prime and ≥22 kVA standby checked → 22 kVA prime / 25 kVA standby model
  • 47 technical lines and 11 spare-part lines answered one by one with document references
  • Controller datasheet used to close analog/digital I/O, 400 event log, web server, GSM, SMS, scheduler, fuel theft lines
  • GSM identified as separate plug-in modem module for the controller
  • -25 °C requirement checked against controller rating (-20 °C) → display heater added
  • Glow plugs checked: direct-injection engine has none

Point-by-point compliance table

ItemRequiredOur proposalAssessment
Prime power20 kVA prime25 kVA standby / 22.5 kVA primeComplies
Frequency and speed50 Hz50 Hz, 1500 rpmComplies
EnclosureSound-attenuated canopyCanopy, 2200 × 1000 × 1550 mmComplies
Fuel tank250 L125 L base tankDeviation / to be confirmed
4 cylinders in-line–Manufacturer declarationComplies
3 start attempts–Controller parameter set to 3Complies
Noise ≤63 dB(A)–Manufacturer declaration, critical silencerComplies
-25…+50 °C–With controller display heaterComplies
250 L tank, heaters, pump, separator, check valve–Included in offered configurationComplies
Spare parts availability 5 years–Manufacturer declarationComplies
Glow plugs in spare kit–Not applicable to direct-injection engineDeviation / to be confirmed

Options identified and priced

  • ATS with mains priority
  • 250 L base-frame tank
  • Fuel tank heater
  • Coolant heater
  • 12 V fuel transfer pump
  • Fuel water separator + check valve
  • Controller upgrade with GSM modem
  • Controller display heater
  • SPTA maintenance kits

Documents prepared · Offer package

  • Commercial offer (line-item structure; prices not published here)
  • Catalogue pages
  • Compliance table
  • Manufacturer’s declaration
  • Manufacturer’s authorisation letter
  • Controller datasheet
  • Catalogue pagesCatalogue pages
  • Spare parts list with type per item sent

Proposed solution

TRX QZ TA 0025

Standby power25 kVA / 20 kW
Prime power22.5 kVA / 18 kW
Voltage · Frequency · Speed230/400 V · 50 Hz · 1,500 rpm
EngineQuartz Q490 · 2.545 L
AlternatorTerex TA160-16N2 · AVR SX460 · IP23/H
Fuel consumption · At 75% load5 L/h
Fuel consumption · At 100% load6.6 L/h
Fuel tank (Canopied (soundproof))125 L
Dimensions (L × W × H) (Canopied (soundproof))2,200 × 1,000 × 1,550 mm · 945 kg
Dimensions (L × W × H) (Open type)1,500 × 1,000 × 1,350 mm · 795 kg

Values are taken from the model’s datasheet; the full datasheet and catalogue page are on the model page.

Offered configuration

  • 250 L base-frame tank with tank heater
  • Coolant heater, 12 V fuel transfer pump, fuel water separator, check valve
  • Mains battery charger 220 V
  • Critical (hospital) type silencer, ≤63 dB(A) (manufacturer declaration)
  • −25…+50 °C with controller display heater (manufacturer declaration)
  • Electronic speed governor

Packing, shipping and export documents

  • Canopy sets are stretch-wrapped with edge protection; loose parts travel in crates or on pallets.
  • Export documents: commercial invoice, packing list, certificate of origin, factory test report.

Customer, tender and site names are withheld; only the country is shown. Prices and commercial terms are not published. Customer documents are not shared; requirements are summarised in our own words.

How we work with your specification

  1. Send the specification, datasheet form or list of needs (PDF, Excel, Word or a message).
  2. We reply on the same working day and ask about missing or unclear points.
  3. We size the power (prime/standby), voltage, frequency, ambient conditions and autonomy, select the model and prepare a point-by-point compliance table. Deviations and options are stated openly.
  4. We send the package — offer, datasheet, catalogue pages and any forms requested; for standard configurations within 24 hours.

Send your specification

No specification yet? Download our specification template for a hospital, school or data centre (Word, PDF)

Chat on WhatsApp

Download