Türkiye – Construction: 1,500 kVA standby canopy set
A request (construction) for 1,500 kVA standby canopy set: we analysed the requirements and selected TRX P ST 1500 (Perkins 4012-46TWG3A, 1,500 kVA standby / 1,350 kVA prime) with 3 alternative configurations, answered 6 points in a compliance table and prepared the documents listed below.
- Country
- Türkiye
- Application
- Construction
- Power
- 1,500 kVA standby / 1,350 kVA prime · 50 Hz
- Quantity
- 1 set
- Source of requirements
- Requirements sent by message or e-mail
Request a quote
Contact us directly
Call +90 216 634 34 06WhatsApp +90 533 582 26 50
We reply in English.
The request
| Rating | 1,500 kVA standby |
|---|---|
| Electrical | 400 V, 50 Hz |
| Enclosure | Sound-attenuated canopy |
| Automatic transfer switch | Yes |
| Other requirements | ABB motorised 3-pole ATS; ABB output breaker |
Our work
Requirement analysis · Model selection and sizing
- Single 1500 kVA set compared with two synchronised sets
- Perkins and Baudouin variants offered
- Synchronised options include transfer function, no separate ATS
Point-by-point compliance table
| Item | Required | Our proposal | Assessment |
|---|---|---|---|
| Standby power | 1,500 kVA standby | 1,500 kVA standby / 1,350 kVA prime | Complies |
| Frequency and speed | 50 Hz | 50 Hz, 1500 rpm | Complies |
| Enclosure | Sound-attenuated canopy | Canopy, 6012 × 2300 × 3962 mm | Complies |
| ABB motorised ATS and output breaker | – | Separate lines | Complies |
| Foundation and cabling | – | Not included | Buyer / local scope |
| First start-up and first fill | – | Included | Complies |
Options identified and priced
- Two-set synchronisation system
- Delivery to site
Documents prepared · Offer package
- Commercial offer (line-item structure; prices not published here)
- Model datasheet
- Catalogue pages
- Revised formal quote form issued after engine selection
Proposed solution
TRX P ST 1500
| Standby power | 1,500 kVA / 1,200 kW |
|---|---|
| Prime power | 1,350 kVA / 1,080 kW |
| Voltage · Frequency · Speed | 230/400 V · 50 Hz · 1,500 rpm |
| Engine | Perkins 4012-46TWG3A · 45.8 L |
| Alternator | Stamford S6L1D-H4 · AVR MX341B · IP23/H |
| Fuel consumption · At 75% load | 212 L/h |
| Fuel consumption · At 100% load | 281 L/h |
| Dimensions (L × W × H) (Open type) | 5,150 × 2,300 × 2,733 mm · 9,241 kg |
Values are taken from the model’s datasheet; the full datasheet and catalogue page are on the model page.
Offered configuration
- Controller: Datakom D-500
- ABB output breaker
- Synchronised 2-set options (sync panels incl. transfer function)
Alternative configurations
- TRX BD ST 1500 – Baudouin 12M33G1500/5, 1,500 kVA standby / 1,375 kVA prime
- TRX P ST 0825 – Perkins 2806A-E18TTAG5, 825 kVA standby / 750 kVA prime
- TRX BD ST 0750 – Baudouin 6M33G750/5, 750 kVA standby / 680 kVA prime
Packing, shipping and export documents
- Transport: ex works Istanbul, with transport arranged on request.
- Canopy sets are stretch-wrapped with edge protection; loose parts travel in crates or on pallets.
Customer, tender and site names are withheld; only the country is shown. Prices and commercial terms are not published. Customer documents are not shared; requirements are summarised in our own words.
How we work with your specification
- Send the specification, datasheet form or list of needs (PDF, Excel, Word or a message).
- We reply on the same working day and ask about missing or unclear points.
- We size the power (prime/standby), voltage, frequency, ambient conditions and autonomy, select the model and prepare a point-by-point compliance table. Deviations and options are stated openly.
- We send the package — offer, datasheet, catalogue pages and any forms requested; for standard configurations within 24 hours.