Türkiye – 1,100 kVA canopy sets
A request for 1,100 kVA canopy sets: we analysed the requirements and selected TRX SD TA 1100 (SDEC 6WTAA35-G31, 1,100 kVA standby / 1,000 kVA prime) with 1 alternative configuration, answered 4 points in a compliance table and prepared the documents listed below.
- Country
- Türkiye
- Power
- 1,100 kVA standby / 1,000 kVA prime · 50 Hz
- Quantity
- Several sets
- Source of requirements
- Requirements sent by message or e-mail
Request a quote
Contact us directly
Call +90 216 634 34 06WhatsApp +90 533 582 26 50
We reply in English.
The request
| Enclosure | Sound-attenuated canopy |
|---|---|
| Other requirements | About 700-850 kW per set; Synchronized operation; Synchronization and transfer panels |
Our work
Requirement analysis · Model selection and sizing
- Two synchronized canopy sets of about 700-850 kW each: 1100 kVA SDEC and 1120 kVA Baudouin options
- Two sets in parallel give 1600-1630 kW prime
- Synchronization panels and breakers for 2 sets, panels also cover the transfer function
Point-by-point compliance table
| Item | Required | Our proposal | Assessment |
|---|---|---|---|
| Enclosure | Sound-attenuated canopy | Canopy, 5276 × 2100 × 3400 mm | Complies |
| About 700-850 kW per set | – | About 800-816 kW prime per set | Complies |
| Synchronization and transfer panels | – | One panel system covers both functions | Complies |
| Installation | – | Not included | Buyer / local scope |
Options identified and priced
- SDEC engine option
- Baudouin engine option
Documents prepared · Offer package
- Commercial offer (line-item structure; prices not published here)
- Model datasheet
- Offer text plus two catalogue PDFs (SD TA 1100 and BD TA 1100)
- Initial oil fill and antifreeze included
Proposed solution
TRX SD TA 1100
| Standby power | 1,100 kVA / 880 kW |
|---|---|
| Prime power | 1,000 kVA / 800 kW |
| Voltage · Frequency · Speed | 230/400 V · 50 Hz · 1,500 rpm |
| Engine | SDEC 6WTAA35-G31 · 35.1 L |
| Alternator | Terex TA400-800N · AVR MX341B · IP23/H |
| Fuel consumption · At 75% load | 136.6 L/h |
| Fuel consumption · At 100% load | 188.1 L/h |
| Fuel tank (Canopied (soundproof)) | 1,754 L |
| Dimensions (L × W × H) (Canopied (soundproof)) | 5,276 × 2,100 × 3,400 mm · 9,023 kg |
| Dimensions (L × W × H) (Open type) | 4,470 × 2,100 × 2,706 mm · 7,625 kg |
Values are taken from the model’s datasheet; the full datasheet and catalogue page are on the model page.
Offered configuration
- Controller: Automatic control
- Synchronization panels and breakers for 2 sets
- Sync panels also cover transfer function
- 1600-1630 kW prime with 2 sets in parallel
Alternative configurations
- TRX BD TA 1100 – Baudouin 12M26G1100/5, 1,120 kVA standby / 1,020 kVA prime
Packing, shipping and export documents
- Lead time as stated in the offer: 2 weeks from order date.
- Transport: ex works Istanbul, with transport arranged on request.
- Canopy sets are stretch-wrapped with edge protection; loose parts travel in crates or on pallets.
Customer, tender and site names are withheld; only the country is shown. Prices and commercial terms are not published. Customer documents are not shared; requirements are summarised in our own words.
How we work with your specification
- Send the specification, datasheet form or list of needs (PDF, Excel, Word or a message).
- We reply on the same working day and ask about missing or unclear points.
- We size the power (prime/standby), voltage, frequency, ambient conditions and autonomy, select the model and prepare a point-by-point compliance table. Deviations and options are stated openly.
- We send the package — offer, datasheet, catalogue pages and any forms requested; for standard configurations within 24 hours.