Egypt – 110–150 kVA canopy sets

A request for 110–150 kVA canopy sets: we analysed the requirements and selected TRX P ST 0150 (Perkins 1106A-70TG1, 150 kVA standby / 135 kVA prime), answered 4 points in a compliance table and prepared the documents listed below.

Country
Egypt
Power
150 kVA standby / 135 kVA prime · 50 Hz
Quantity
Series supply (many sets)
Source of requirements
Requirements sent by message or e-mail

Request a quote

Contact us directly

Call +90 216 634 34 06WhatsApp +90 533 582 26 50

We reply in English.

Your request has been received. We will contact you as soon as possible.

Could not send. Please try again or call us. You can also reach us directly: WhatsApp +90 533 582 26 50 · info@terexdiesel.com

Too many submissions in a short time. Please try again in a few minutes.

More details? Use the full request form

The request

Rating100 / 150 kVA
EnclosureSound-attenuated canopy
Automatic transfer switchYes
Engine brandPerkins
Other requirementsOperation and maintenance guide requested

Our work

Requirement analysis · Model selection and sizing

  • No Perkins model at 100 kVA standby: next model with 110 kVA standby / 100 kVA prime offered for the 100 kVA line
  • 6 x 150 kVA and 1 x 110 kVA Perkins, Stamford, Deep Sea DSE, canopy, ATS 250 A per set
  • Load plan: 6 x 150 kVA fit one 40 ft HC; the 110 kVA set needs a separate 20 ft

Point-by-point compliance table

ItemRequiredOur proposalAssessment
Engine brandPerkinsPerkins 1106A-70TG1Complies
EnclosureSound-attenuated canopyCanopy, 3220 × 1100 × 1845 mmComplies
100 kVA–110 kVA standby / 100 kVA prime model offeredDeviation / to be confirmed
Operation and maintenance guide–Included in the document packageComplies

Documents prepared · Offer package

  • Commercial offer (line-item structure; prices not published here)
  • Catalogue pages
  • Factory load-test report (sample)
  • Warranty terms document
  • Start-up and handover form
  • Maintenance and service forms
  • Operating and maintenance manual
  • Controller datasheet
  • Factory load-test report (sample)Factory load-test report (sample)
  • Warranty terms documentWarranty terms document
  • Start-up and handover formStart-up and handover form

Proposed solution

TRX P ST 0150

Standby power150 kVA / 120 kW
Prime power135 kVA / 108 kW
Voltage · Frequency · Speed230/400 V · 50 Hz · 1,500 rpm
EnginePerkins 1106A-70TG1 · 7.01 L
AlternatorStamford UCI274E · AVR SX460 · IP23/H
Fuel consumption · At 75% load22.7 L/h
Fuel consumption · At 100% load30.3 L/h
Fuel tank (Canopied (soundproof))272 L
Dimensions (L × W × H) (Canopied (soundproof))3,220 × 1,100 × 1,845 mm · 1,822 kg
Dimensions (L × W × H) (Open type)2,600 × 1,100 × 1,680 mm · 1,516 kg

TRX P ST 0110

Standby power110 kVA / 88 kW
Prime power100 kVA / 80 kW
Voltage · Frequency · Speed230/400 V · 50 Hz · 1,500 rpm
EnginePerkins 1104C-44TAG2 · 4.4 L
AlternatorStamford UCI274C · AVR SX460 · IP23/H
Fuel consumption · At 75% load20.2 L/h
Fuel consumption · At 100% load26.9 L/h
Fuel tank (Canopied (soundproof))139 L
Dimensions (L × W × H) (Canopied (soundproof))2,600 × 1,000 × 1,570 mm · 1,352 kg
Dimensions (L × W × H) (Open type)2,200 × 1,000 × 1,385 mm · 1,127 kg

Values are taken from the model’s datasheet; the full datasheet and catalogue page are on the model page.

Offered configuration

  • Controller: Deep Sea DSE
  • 110 kVA standby / 100 kVA prime offered for the 100 kVA request

Packing, shipping and export documents

  • Loading: 1 x 40' HC + 1 x 20' (6 sets in the 40' HC, 1 set in the 20')
  • Transport: sea freight in containers.
  • Canopy sets are stretch-wrapped with edge protection; loose parts travel in crates or on pallets.
  • Export documents: commercial invoice, packing list, certificate of origin, factory test report.

Customer, tender and site names are withheld; only the country is shown. Prices and commercial terms are not published. Customer documents are not shared; requirements are summarised in our own words.

How we work with your specification

  1. Send the specification, datasheet form or list of needs (PDF, Excel, Word or a message).
  2. We reply on the same working day and ask about missing or unclear points.
  3. We size the power (prime/standby), voltage, frequency, ambient conditions and autonomy, select the model and prepare a point-by-point compliance table. Deviations and options are stated openly.
  4. We send the package — offer, datasheet, catalogue pages and any forms requested; for standard configurations within 24 hours.

Send your specification

No specification yet? Download our specification template for a hospital, school or data centre (Word, PDF)

Chat on WhatsApp

Download