Volvo Penta 60 Hz Diesel Generators (1,800 rpm)
21 Volvo Penta-engined models for 60 Hz / 1,800 rpm: 423–765 kVA standby at 480/277 V. 440/254 V, 380/220 V and 220/127 V on request.
60 Hz datasheets, dimensions and weights are sent with the quote.
Volvo Penta 60 Hz Generators
| Model | Standby power | Prime power | Engine | Alternator |
|---|---|---|---|---|
| TRX VL MC 0385-60 HZ | 423 kVA / 339 kW | 387 kVA / 310 kW | Volvo Penta TAD1342GE | Mecc Alte ECO40-1S/4 |
| TRX VL TA 0385-60 HZ | 423 kVA / 339 kW | 387 kVA / 310 kW | Volvo Penta TAD1342GE | Terex TA315-300N |
| TRX VL ST 0385-60 HZ | 435 kVA / 348 kW | 395 kVA / 316 kW | Volvo Penta TAD1342GE | Stamford S4L1D-E |
| TRX VL ST 0415-60 HZ | 436 kVA / 349 kW | 396 kVA / 317 kW | Volvo Penta TAD1343GE | Stamford S4L1D-E |
| TRX VL MC 0415-60 HZ | 436 kVA / 349 kW | 396 kVA / 317 kW | Volvo Penta TAD1343GE | Mecc Alte ECO40-1S/4 |
| TRX VL TA 0415-60 HZ | 436 kVA / 349 kW | 396 kVA / 317 kW | Volvo Penta TAD1343GE | Terex TA315-320N |
| TRX VL MC 0440-60 HZ | 480 kVA / 384 kW | 440 kVA / 352 kW | Volvo Penta TAD1344GE | Mecc Alte ECO40-1S/4 |
| TRX VL ST 0500-60 HZ | 483 kVA / 387 kW | 440 kVA / 352 kW | Volvo Penta TAD1345GE | Stamford S4L1D-G |
| TRX VL MC 0500-60 HZ | 483 kVA / 387 kW | 440 kVA / 352 kW | Volvo Penta TAD1345GE | Mecc Alte ECO40-2S/4 |
| TRX VL TA 0440-60 HZ | 483 kVA / 387 kW | 440 kVA / 352 kW | Volvo Penta TAD1344GE | Terex TA315-320N |
| TRX VL TA 0500-60 HZ | 483 kVA / 387 kW | 440 kVA / 352 kW | Volvo Penta TAD1345GE | Terex TA315-350N |
| TRX VL ST 0440-60 HZ | 500 kVA / 400 kW | 455 kVA / 364 kW | Volvo Penta TAD1344GE | Stamford S4L1D-F |
| TRX VL TA 0630-60 HZ | 657 kVA / 526 kW | 597 kVA / 478 kW | Volvo Penta TAD1642GE | Terex TA355-470N |
| TRX VL ST 0630-60 HZ | 685 kVA / 548 kW | 623 kVA / 498 kW | Volvo Penta TAD1642GE | Stamford S5L1D-E41 |
| TRX VL MC 0630-60 HZ | 685 kVA / 548 kW | 623 kVA / 498 kW | Volvo Penta TAD1642GE | Mecc Alte ECO40-2L/4 |
| TRX VL ST 0715-60 HZ | 720 kVA / 576 kW | 653 kVA / 523 kW | Volvo Penta TWD1644GE | Stamford S5L1D-F41 |
| TRX VL MC 0715-60 HZ | 720 kVA / 576 kW | 653 kVA / 523 kW | Volvo Penta TWD1644GE | Mecc Alte ECO40-3L/4 |
| TRX VL TA 0715-60 HZ | 720 kVA / 576 kW | 653 kVA / 523 kW | Volvo Penta TWD1644GE | Terex TA355-550N |
| TRX VL ST 0770-60 HZ | 765 kVA / 612 kW | 696 kVA / 557 kW | Volvo Penta TWD1645GE | Stamford S6L1D-C4 |
| TRX VL MC 0770-60 HZ | 765 kVA / 612 kW | 696 kVA / 557 kW | Volvo Penta TWD1645GE | Mecc Alte ECO40-VL/4 |
| TRX VL TA 0770-60 HZ | 765 kVA / 612 kW | 696 kVA / 557 kW | Volvo Penta TWD1645GE | Terex TA355-600N |
50 Hz or 60 Hz?
A four-pole alternator produces 50 Hz at 1,500 rpm and 60 Hz at 1,800 rpm. The engine gives more power at 1,800 rpm, but the set rating depends on the engine, the alternator and the voltage. That is why each 60 Hz model has its own rating rather than a fixed ratio to the 50 Hz value. 50 Hz vs 60 Hz Generators