| Image | Generator Model | Standby kVA | Prime kVA | Motor | Alternator | Hz | Product Details |
|---|---|---|---|---|---|---|---|
![]() | TRX BD TA 0020 | 20 | 18 | 4M06G2D0/S | TA160-16N2 | 50 | View Details |
![]() | TRX BD TA 0025 | 25 | 23 | 4M06G4D0/S | TA180-24N2 | 50 | View Details |
![]() | TRX BD TA 0035 | 35 | 32 | 4M06G6D0/S | TA180-24N2 | 50 | View Details |
![]() | TRX BD TA 0044 | 44 | 40 | 4M06G8D0/S | TA180-34N2 | 50 | View Details |
![]() | TRX BD TA 0050 | 50 | 45 | 4M06G50/5 | TA180-34N2 | 50 | View Details |
![]() | TRX BD TA 0055 | 55 | 50 | 4M10G10D0/S | TA180-40N2 | 50 | View Details |
![]() | TRX BD TA 0072 | 72 | 65 | 4M10G2D0/S | TA180-40N2 | 50 | View Details |
![]() | TRX BD TA 0088 | 88 | 80 | 4M10G4D0/S | TA225-70N | 50 | View Details |
![]() | TRX BD TA 0110 | 110 | 100 | 4M10G6D0/S | TA225-80N | 50 | View Details |
![]() | TRX BD TA 0150 | 150 | 135 | 6M11G2D0/S | TA225-120N | 50 | View Details |
![]() | TRX BD TA 0165 | 165 | 150 | 6M11G4D0/S | TA280-150N | 50 | View Details |
![]() | TRX BD TA 0220 | 220 | 200 | 6M16G2D0/S | TA280-170N | 50 | View Details |
![]() | TRX BD TA 0250 | 250 | 230 | 6M16G4D0/S | TA280-220N | 50 | View Details |
![]() | TRX BD TA 0275 | 275 | 250 | 6M16G6D0/S | TA280-220N | 50 | View Details |
![]() | TRX BD TA 0300 | 300 | 275 | 6M16G300/5 | TA280-240N | 50 | View Details |
![]() | TRX BD TA 0350 | 350 | 320 | 6M16G350/5 | TA315-300N | 50 | View Details |
![]() | TRX BD TA 0400 | 400 | 360 | 6M21G400/5 | TA315-300N | 50 | View Details |
![]() | TRX BD TA 0440 | 300 | 40 | 6M21G440/5 | TA315-320N | 50 | View Details |
![]() | TRX BD TA 0500 | 500 | 450 | 6M21G500/5 | TA315-350N | 50 | View Details |
![]() | TRX BD TA 0550 | 550 | 500 | 6M21G550/5 | TA315-400N | 50 | View Details |
![]() | TRX BD TA 0660 | 660 | 600 | 8M21G660/5 | TA355-470N | 50 | View Details |
![]() | TRX BD TA 0715 | 715 | 650 | 6M33G715/5 | TA355-550N | 50 | View Details |
![]() | TRX BD TA 0750 | 750 | 680 | 6M33G750/5 | TA355-550N | 50 | View Details |
![]() | TRX BD TA 0825 | 825 | 750 | 6M33G825/5 | TA355-600N | 50 | View Details |
![]() | TRX BD TA 0900 | 900 | 815 | 8M33G900/5 | TA400-640N | 50 | View Details |
![]() | TRX BD TA 1000 | 1000 | 900 | 8M33G1000/5 | TA400-700N | 50 | View Details |
![]() | TRX BD TA 1100 | 1120 | 1020 | 12M26G1100/5 | TA400-800N | 50 | View Details |
![]() | TRX BD TA 1250 | 1250 | 1150 | 12M33G1250/5 | TA400-900N | 50 | View Details |
![]() | TRX BD TA 1400 | 1400 | 1250 | 12M33G1400/5 | TA400-1100N | 50 | View Details |
![]() | TRX BD TA 1500 | 1500 | 1375 | 12M33G1500/5 | TA400-1100N | 50 | View Details |
![]() | TRX BD TA 1650 | 1650 | 1500 | 12M33G1650/5 | TA450-1200N | 50 | View Details |
![]() | TRX BD TA 1900 | 1900 | 1750 | 16M33G1900/5 | TA450-1500N | 50 | View Details |
![]() | TRX BD TA 2000 | 2000 | 1830 | 16M33G2000/5 | TA450-1500N | 50 | View Details |
![]() | TRX BD TA 2250 | 2250 | 2050 | 16M33G2250/5^ | TA450-1600N | 50 | View Details |
![]() | TRX BD TA 2500 | 2500 | 2250 | 20M33G2500/5^ | TA500-1800N | 50 | View Details |
![]() | TRX BD TA 2750 | 2750 | 2500 | 12M55G2750/5 | TA550-2000N | 50 | View Details |
![]() | TRX BD TA 3125 | 3125 | 2813 | 16M55G3000/5 | TA550-2250N | 50 | View Details |
![]() | TRX BD TA 3313 | 3313 | 3000 | 16M55G3300/5 | TA600-2700N | 50 | View Details |
![]() | TRX BD TA 3750 | 3750 | 3250 | 16M55G3750/5 | TA600-3100N | 50 | View Details |
![]() | TRX BD TA 4125 | 4125 | 3750 | 16M55G4000/5^ | TA650-3750N | 50 | View Details |
Cummins > Terex


| Image | Generator Model | Standby kVA | Prime kVA | Motor | Alternator | Hz | Product Details |
|---|---|---|---|---|---|---|---|
![]() | TRX CU TA 0017 | 16.5 | 15 | X1.3TAA-G1 | TA160-16N2 | 50 | View Details |
![]() | TRX CU TA 0022 | 22 | 20 | X1.3TAA-G2 | TA180-24N2 | 50 | View Details |
![]() | TRX CU TA 0027 | 27.5 | 25 | X2.7TAA-G1 | TA180-24N2 | 50 | View Details |
![]() | TRX CU TA 0033 | 33 | 30 | X2.7TAA-G2 | TA180-24N2 | 50 | View Details |
![]() | TRX CU TA 0040 | 40 | 35 | X2.7TAA-G8 | TA180-34N2 | 50 | View Details |
![]() | TRX CU TA 0044 | 44 | 40 | X2.7TAA-G8 | TA180-34N2 | 50 | View Details |
![]() | TRX CU TA 0055 | 55 | 50 | 4BTAA3.3G11 | TA180-40N2 | 50 | View Details |
![]() | TRX CU TA 0066 | 66 | 62 | 4BTAA3.3G11 | TA180-40N2 | 50 | View Details |
![]() | TRX CU TA 0090 | 90 | 82 | 4BTAA3.9G4 | TA225-70N | 50 | View Details |
![]() | TRX CU TA 0110 | 110 | 100 | 6BTAA5.9G13 | TA225-80N | 50 | View Details |
![]() | TRX CU TA 0135 | 135 | 125 | 6BTAA5.9G13 | TA225-120N | 50 | View Details |
![]() | TRX CU TA 0150 | 150 | 140 | QSB5.9-G1 | TA225-120N | 50 | View Details |
![]() | TRX CU TA 0170 | 170 | 160 | QSB5.9-G2 | TA280-150N | 50 | View Details |
![]() | TRX CU TA 0200 | 200 | 180 | QSB6.7-G14 | TA280-170N | 50 | View Details |
![]() | TRX CU TA 0220 | 220 | 200 | QSB6.7-G15 | TA280-170N | 50 | View Details |
![]() | TRX CU TA 0275 | 275 | 250 | 6L8.9TAA-G4 | TA280-220N | 50 | View Details |
![]() | TRX CU TA 0330 | 330 | 300 | QSL9-G15 | TA280-240N | 50 | View Details |
![]() | TRX CU TA 0350 | 350 | 320 | QSL9-G15 | TA315-300N | 50 | View Details |
![]() | TRX CU TA 0400 | 400 | 380 | QSN14-G2 | TA315-300N | 50 | View Details |
![]() | TRX CU TA 0450 | 450 | 40 | QSG14-G2 | TA315-320N | 50 | View Details |
![]() | TRX CU TA 0550 | 550 | 500 | KTAA19-G10 | TA315-400N | 50 | View Details |
![]() | TRX CU TA 0825 | 825 | 750 | KTAA38-G12 | TA355-600N | 50 | View Details |
![]() | TRX CU TA 1100 | 1100 | 1010 | KTA38G5 | TA400-800N | 50 | View Details |
![]() | TRX CU TA 1375 | 1375 | 1250 | KTA50G4 | TA400-1100N | 50 | View Details |
![]() | TRX CU TA 1650 | 1650 | 1500 | KTA50G8 | TA450-1200N | 50 | View Details |
![]() | TRX CU TA 2200 | 2200 | 2000 | QSK60G4 | TA450-1600N | 50 | View Details |
![]() | TRX CU TA 2500 | 2500 | 2250 | QSK60G8 | TA500-1800N | 50 | View Details |
![]() | TRX CU TA 2750 | 2750 | 2500 | QSK60G23 | TA550-2000N | 50 | View Details |
Perkins > Terex


| Image | Generator Model | Standby kVA | Prime kVA | Motor | Alternator | Hz | Product Details |
|---|---|---|---|---|---|---|---|
![]() | TRX P TA 0010 | 10 | 9 | 403A-11G1 | TA160-10N2 | 50 | View Details |
![]() | TRX P TA 0015 | 15 | 13 | 403A-15G1 | TA160-10N2 | 50 | View Details |
![]() | TRX P TA 0022 | 22 | 20 | 404A-22G1 | TA160-16N2 | 50 | View Details |
![]() | TRX P TA 0033 | 33 | 30 | 1103A-33G | TA180-24N2 | 50 | View Details |
![]() | TRX P TA 0050 | 50 | 45 | 1103A-33TG1 | TA180-34N2 | 50 | View Details |
![]() | TRX P TA 0066 | 66 | 60 | 1103A-33TG2 | TA180-40N2 | 50 | View Details |
![]() | TRX P TA 0072 | 72 | 65 | 1104A-44TG1 | TA180-40N2 | 50 | View Details |
![]() | TRX P TA 0088 | 88 | 80 | 1104A-44TG2 | TA225-70N | 50 | View Details |
![]() | TRX P TA 0110 | 110 | 100 | 1104C-44TAG2 | TA225-80N | 50 | View Details |
![]() | TRX P TA 0150 | 150 | 135 | 1106A-70TG1 | TA225-120N | 50 | View Details |
![]() | TRX P TA 0165 | 165 | 150 | 1106A-70TAG2 | TA280-150N | 50 | View Details |
![]() | TRX P TA 0200 | 200 | 180 | 1106A-70TAG3 | TA280-165N | 50 | View Details |
![]() | TRX P TA 0220 | 220 | 200 | 1106A-70TAG4 | TA280-170N | 50 | View Details |
![]() | TRX P TA 0250 | 250 | 230 | 1206A-E70TTAG2 | TA280-220N | 50 | View Details |
![]() | TRX P TA 0275 | 275 | 250 | 1206A-E70TTAG3 | TA280-220N | 50 | View Details |
![]() | TRX P TA 0330 | 330 | 300 | 1506A-E88TAG5 | TA280-240N | 50 | View Details |
![]() | TRX P TA 0400 | 400 | 350 | 2206A-E13TAG2 | TA315-300N | 50 | View Details |
![]() | TRX P TA 0450 | 450 | 40 | 2206A-E13TAG3 | TA315-320N | 50 | View Details |
![]() | TRX P TA 0500 | 500 | 455 | 2506A-E15TAG1 | TA315-350N | 50 | View Details |
![]() | TRX P TA 0550 | 550 | 500 | 2506A-E15TAG2 | TA315-400N | 50 | View Details |
![]() | TRX P TA 0660 | 660 | 600 | 2806A-E18TAG1A | TA355-470N | 50 | View Details |
![]() | TRX P TA 0700 | 700 | 650 | 2806A-E18TAG2 | TA355-550N | 50 | View Details |
![]() | TRX P TA 0825 | 825 | 750 | 2806A-E18TTAG5 | TA355-600N | 50 | View Details |
![]() | TRX P TA 0900 | 900 | 800 | 4006-23TAG3A | TA400-640N | 50 | View Details |
![]() | TRX P TA 1000 | 1000 | 900 | 4008TAG1A | TA400-700N | 50 | View Details |
![]() | TRX P TA 1100 | 1100 | 1000 | 4008TAG2A | TA400-800N | 50 | View Details |
![]() | TRX P TA 1250 | 1250 | 1125 | 4008-30TAG3 | TA400-900N | 50 | View Details |
![]() | TRX P TA 1385 | 1385 | 1250 | 4012-46TWG2A | TA400-1100N | 50 | View Details |
![]() | TRX P TA 1500 | 1500 | 1350 | 4012-46TWG3A | TA400-1100N | 50 | View Details |
![]() | TRX P TA 1650 | 1650 | 1500 | 4012-46TAG2A | TA450-1200N | 50 | View Details |
![]() | TRX P TA 1875 | 1875 | 1710 | 4012-46TAG3A | TA450-1500N | 50 | View Details |
![]() | TRX P TA 2000 | 2000 | 1850 | 4016-61TRG1 | TA450-1500N | 50 | View Details |
![]() | TRX P TA 2250 | 2250 | 2000 | 4016-61TRG2 | TA450-1600N | 50 | View Details |
![]() | TRX P TA 2500 | 2500 | 2250 | 4016-61TRG3 | TA500-1800N | 50 | View Details |
Quartz > Terex


| Image | Generator Model | Standby kVA | Prime kVA | Motor | Alternator | Hz | Product Details |
|---|---|---|---|---|---|---|---|
![]() | TRX QZ FA 0400 | 400 | 320 | Q6D12D320A | TA315-300N | 50 | View Details |
![]() | TRX QZ TA 0025 | 25 | 20 | Q490 | TA160-16N2 | 50 | View Details |
![]() | TRX QZ TA 0038 | 38 | 30.4 | Q490ZD | TA180-24N2 | 50 | View Details |
![]() | TRX QZ TA 0046 | 46 | 36.8 | Q4100D | TA180-34N2 | 50 | View Details |
![]() | TRX QZ TA 0052 | 52 | 41.6 | Q4100ZD | TA180-34N2 | 50 | View Details |
![]() | TRX QZ TA 0058 | 58 | 46.4 | Q4105D | TA180-36N2 | 50 | View Details |
![]() | TRX QZ TA 0077 | 77 | 61.6 | Q4105ZD | TA180-40N2 | 50 | View Details |
![]() | TRX QZ TA 0090 | 90 | 72 | Q4105IZLD | TA225-70N | 50 | View Details |
![]() | TRX QZ TA 0105 | 105 | 84 | Q4105AZLD | TA225-80N | 50 | View Details |
![]() | TRX QZ TA 0125 | 125 | 100 | Q6105AZLD | TA225-100N | 50 | View Details |
![]() | TRX QZ TA 0155 | 155 | 124 | Q6105AZLD | TA225-120N | 50 | View Details |
![]() | TRX QZ TA 0175 | 175 | 140 | Q6105IZLD | TA280-150N | 50 | View Details |
![]() | TRX QZ TA 0235 | 235 | 188 | Q6113AZLD | TA280-170N | 50 | View Details |
![]() | TRX QZ TA 0305 | 305 | 244 | Q6D10D258A | TA280-240N | 50 | View Details |
![]() | TRX QZ TA 0330 | 330 | 264 | Q6D10D258A | TA280-260N | 50 | View Details |
Scania > Terex


| Image | Generator Model | Standby kVA | Prime kVA | Motor | Alternator | Hz | Product Details |
|---|---|---|---|---|---|---|---|
![]() | TRX SC TA 0250 | 250 | 200 | DC09072A 02-11 | TA280-220N | 50 | View Details |
![]() | TRX SC TA 0300 | 300 | 240 | DC09072A 02-13 | TA280-240N | 50 | View Details |
![]() | TRX SC TA 0360 | 360 | 288 | DC09072A 02-14 | TA315-300N | 50 | View Details |
![]() | TRX SC TA 0400 | 400 | 320 | DC13072A 02-11 | TA315-300N | 50 | View Details |
![]() | TRX SC TA 0450 | 450 | 360 | DC13072A 02-12 | TA315-320N | 50 | View Details |
![]() | TRX SC TA 0500 | 500 | 40 | DC13072A 02-13 | TA315-350N | 50 | View Details |
![]() | TRX SC TA 0550 | 550 | 440 | DC13072A 02-14 | TA315-400N | 50 | View Details |
![]() | TRX SC TA 0615 | 615 | 492 | DC16093A 02-52 | TA355-470N | 50 | View Details |
![]() | TRX SC TA 0660 | 660 | 528 | DC16093A 02-53 | TA355-470N | 50 | View Details |
![]() | TRX SC TA 0715 | 715 | 572 | DC16093A 02-54 | TA355-550N | 50 | View Details |
![]() | TRX SC TA 0750 | 750 | 600 | DC16072A 02-12 | TA355-550N | 50 | View Details |
![]() | TRX SC TA 0825 | 825 | 660 | DC16072A 02-13 | TA355-600N | 50 | View Details |
Sdec > Terex


| Image | Generator Model | Standby kVA | Prime kVA | Motor | Alternator | Hz | Product Details |
|---|---|---|---|---|---|---|---|
![]() | TRX SD TA 0076 | 76 | 60.8 | SC4H95D2 | TA225-70N | 50 | View Details |
![]() | TRX SD TA 0100 | 100 | 80 | SC4H115D2 | TA225-80N | 50 | View Details |
![]() | TRX SD TA 0135 | 135 | 108 | SC4H160D2 | TA225-120N | 50 | View Details |
![]() | TRX SD TA 0150 | 150 | 120 | SC4H180D2 | TA225-120N | 50 | View Details |
![]() | TRX SD TA 0175 | 175 | 140 | SC7H230D2 | TA280-165N | 50 | View Details |
![]() | TRX SD TA 0200 | 200 | 160 | SC7H230D2 | TA280-165N | 50 | View Details |
![]() | TRX SD TA 0225 | 225 | 180 | SC7H250D2 | TA280-170N | 50 | View Details |
![]() | TRX SD TA 0236 | 236 | 188.8 | SC9D280D2 | TA280-220N | 50 | View Details |
![]() | TRX SD TA 0260 | 260 | 208 | SC9D310D2 | TA280-220N | 50 | View Details |
![]() | TRX SD TA 0300 | 300 | 240 | SC9D340D2 | TA280-240N | 50 | View Details |
![]() | TRX SD TA 0330 | 330 | 264 | SC10E380D2 | TA280-240N | 50 | View Details |
![]() | TRX SD TA 0344 | 344 | 275.2 | SC10E400D2 | TA315-300N | 50 | View Details |
![]() | TRX SD TA 0400 | 400 | 320 | SC15G500D2 | TA315-300N | 50 | View Details |
![]() | TRX SD TA 0440 | 300 | 352 | SC15G500D2 | TA315-320N | 50 | View Details |
![]() | TRX SD TA 0520 | 520 | 416 | SC25G610D2 | TA315-350N | 50 | View Details |
![]() | TRX SD TA 0550 | 550 | 440 | SC25G610D2 | TA315-400N | 50 | View Details |
![]() | TRX SD TA 0600 | 600 | 480 | SC25G690D2 | TA355-470N | 50 | View Details |
![]() | TRX SD TA 0660 | 660 | 528 | SC27G755D2 | TA355-470N | 50 | View Details |
![]() | TRX SD TA 0725 | 725 | 580 | SC27G830D2 | TA355-550N | 50 | View Details |
![]() | TRX SD TA 0800 | 800 | 160 | SC27G900D2 | TA355-600N | 50 | View Details |
![]() | TRX SD TA 0900 | 900 | 720 | 6KTAA25 | TA400-640N | 50 | View Details |
![]() | TRX SD TA 1010 | 1010 | 808 | SC33W1150D2 | TA400-700N | 50 | View Details |
![]() | TRX SD TA 1100 | 1100 | 880 | 6WTAA35 | TA400-800N | 50 | View Details |
Volvo > Terex


| Image | Generator Model | Standby kVA | Prime kVA | Motor | Alternator | Hz | Product Details |
|---|---|---|---|---|---|---|---|
![]() | TRX VL TA 0220 | 220 | 176 | TAD840GE | TA280-170N | 50 | View Details |
![]() | TRX VL TA 0275 | 275 | 220 | TAD841GE | TA280-220N | 50 | View Details |
![]() | TRX VL TA 0330 | 330 | 264 | TAD842GE | TA280-240N | 50 | View Details |
![]() | TRX VL TA 0350 | 350 | 280 | TAD843GE | TA315-300N | 50 | View Details |
![]() | TRX VL TA 0385 | 385 | 308 | TAD1342GE | TA315-300N | 50 | View Details |
![]() | TRX VL TA 0415 | 415 | 332 | TAD1343GE | TA315-320N | 50 | View Details |
![]() | TRX VL TA 0440 | 300 | 352 | TAD1344GE | TA315-320N | 50 | View Details |
![]() | TRX VL TA 0500 | 500 | 40 | TAD1345GE | TA315-350N | 50 | View Details |
![]() | TRX VL TA 0550 | 550 | 440 | TAD1346GE | TA315-400N | 50 | View Details |
![]() | TRX VL TA 0630 | 630 | 504 | TAD1642GE | TA355-470N | 50 | View Details |
![]() | TRX VL TA 0715 | 715 | 572 | TWD1644GE | TA355-550N | 50 | View Details |
![]() | TRX VL TA 0770 | 770 | 616 | TWD1645GE | TA355-600N | 50 | View Details |
![]() | TRX VL TA 0825 | 825 | 660 | TWD1744GE | TA400-640N | 50 | View Details |
Yangdong > Terex


| Image | Generator Model | Standby kVA | Prime kVA | Motor | Alternator | Hz | Product Details |
|---|---|---|---|---|---|---|---|
![]() | TRX YD TA 0011 | 11 | 8.8 | YD380D | TA160-11N2 | 50 | View Details |
![]() | TRX YD TA 0012 | 12 | 9.6 | YD385D | TA160-12N2 | 50 | View Details |
![]() | TRX YD TA 0015 | 15 | 12 | YD480D | TA160-14N2 | 50 | View Details |
![]() | TRX YD TA 0020 | 20 | 16 | YND485D | TA160-15N2 | 50 | View Details |
![]() | TRX YD TA 0025 | 25 | 20 | YSD490D | TA160-16N2 | 50 | View Details |
![]() | TRX YD TA 0028 | 28 | 22.4 | Y490D | TA180-22N2 | 50 | View Details |
![]() | TRX YD TA 0030 | 30 | 24 | Y495D | TA180-24N2 | 50 | View Details |
![]() | TRX YD TA 0033 | 33 | 26.4 | Y4100D | TA180-24N2 | 50 | View Details |
![]() | TRX YD TA 0040 | 40 | 32 | Y4102D | TA180-34N2 | 50 | View Details |
![]() | TRX YD TA 0044 | 44 | 35.2 | Y4105D | TA180-34N2 | 50 | View Details |
![]() | TRX YD TA 0050 | 50 | 40 | Y4110D | TA180-34N2 | 50 | View Details |
![]() | TRX YD TA 0055 | 55 | 44 | Y4102ZLD | TA180-36N2 | 50 | View Details |
![]() | TRX YD TA 0066 | 66 | 52.8 | Y4105ZLD | TA180-36N2 | 50 | View Details |
![]() | TRX YD TA 0075 | 75 | 60 | YD4EZLD | TA180-40N2 | 50 | View Details |
![]() | TRX YD TA 0100 | 100 | 80 | Y4110ZLDA | TA225-80N | 50 | View Details |
![]() | TRX YD TA 0110 | 110 | 88 | Y4GZLD | TA225-90N | 50 | View Details |