Polsha – 25–44 kVA generator agregatlari
25–44 kVA generator agregatlari uchun so‘rov: talablarni tahlil qildik, TRX YD TA 0025 (Yangdong YSD490D, 25 kVA zaxira / 22 kVA asosiy quvvat) modelini tanladik, muvofiqlik jadvalida 3 ta bandga javob berdik va quyida keltirilgan hujjatlarni tayyorladik.
- Davlat
- Polsha
- Quvvat
- 25 kVA standby / 22 kVA prime · 50 Hz
- Soni
- Bir nechta dona
- Talablar manbai
- Talablar xabar yoki e-pochta orqali yuborilgan
Taklif va ma’lumot so‘rovi
Biz bilan bevosita bog‘laning
Qo‘ng‘iroq +90 216 634 34 06WhatsApp +90 533 582 26 50
O‘zbek tilida javob beramiz.
So‘rov
| Quvvat | 25 / 30 / 45 kVA |
|---|---|
| Dvigatel markasi | Yangdong |
Bajargan ishimiz
Talablar tahlili · Model tanlash va quvvatni hisoblash
- 25/30/45 kVA ga moslashtirilgan uchta Yangdong modeli
Band-band muvofiqlik jadvali
| Band | Talab | Taklifimiz | Baholash |
|---|---|---|---|
| Dvigatel markasi | Yangdong | Yangdong YSD490D | Mos keladi |
| O‘rnatish himoyasi (oqish tokidan himoya, avtomatik o‘chirgich, o‘tkazish tizimi) | – | Taklifga ko‘ra o‘rnatish mijoz zimmasida | Xaridor / mahalliy tomon |
| Dvigatel moyi, antifriz, tebranishga qarshi tayanchlar | – | Kiritilgan | Mos keladi |
Tayyorlangan hujjatlar · Taklif paketi
- Tijorat taklifi (bandlar tuzilmasi; narxlar bu yerda e’lon qilinmaydi)
- Katalog sahifalari
- Zavod yuklama sinovi hisoboti (namuna)
- Alternator texnik varag‘i
Zavod yuklama sinovi hisoboti (namuna)
- Yetkazib berishdan oldin zavod sinovi; sinov hisoboti agregat bilan birga taqdim etiladi
Taklif etilgan yechim
TRX YD TA 0025
| Zaxira quvvati (Standby) | 25 kVA / 20 kW |
|---|---|
| Asosiy quvvat (Prime) | 22 kVA / 17,6 kW |
| Kuchlanish · Chastota · Aylanish tezligi | 230/400 V · 50 Hz · 1 500 ayl/daq |
| Dvigatel | Yangdong YSD490D · 2,54 L |
| Alternator | Terex TA160-16N2 · AVR SX460 · IP23/H |
| Yoqilg‘i sarfi · 75% yuklamada | 5,64 L/soat |
| Yoqilg‘i sarfi · 100% yuklamada | 6,36 L/soat |
| Yoqilg‘i baki (Kabinali (shovqin izolyatsiyali)) | 100 L |
| O‘lchamlar (U × E × B) (Kabinali (shovqin izolyatsiyali)) | 1 800 × 1 000 × 1 250 mm · 798 kg |
| O‘lchamlar (U × E × B) (Ochiq turdagi) | 1 200 × 1 000 × 1 050 mm · 698 kg |
TRX YD TA 0033
| Zaxira quvvati (Standby) | 33 kVA / 26,4 kW |
|---|---|
| Asosiy quvvat (Prime) | 30 kVA / 24 kW |
| Kuchlanish · Chastota · Aylanish tezligi | 230/400 V · 50 Hz · 1 500 ayl/daq |
| Dvigatel | Yangdong Y4100D · 3,707 L |
| Alternator | Terex TA180-24N2 · AVR SX460 · IP23/H |
| Yoqilg‘i sarfi · 75% yuklamada | 5,69 L/soat |
| Yoqilg‘i sarfi · 100% yuklamada | 7,29 L/soat |
| Yoqilg‘i baki (Kabinali (shovqin izolyatsiyali)) | 100 L |
| O‘lchamlar (U × E × B) (Kabinali (shovqin izolyatsiyali)) | 1 800 × 1 000 × 1 250 mm · 1 065 kg |
| O‘lchamlar (U × E × B) (Ochiq turdagi) | 1 200 × 1 000 × 1 050 mm · 965 kg |
TRX YD TA 0044
| Zaxira quvvati (Standby) | 44 kVA / 35,2 kW |
|---|---|
| Asosiy quvvat (Prime) | 40 kVA / 32 kW |
| Kuchlanish · Chastota · Aylanish tezligi | 230/400 V · 50 Hz · 1 500 ayl/daq |
| Dvigatel | Yangdong Y4105D |
| Alternator | Terex TA180-34N2 · AVR SX460 · IP23/H |
| Yoqilg‘i sarfi · 75% yuklamada | 6,75 L/soat |
| Yoqilg‘i sarfi · 100% yuklamada | 8,8 L/soat |
| Yoqilg‘i baki (Kabinali (shovqin izolyatsiyali)) | 101 L |
| O‘lchamlar (U × E × B) (Kabinali (shovqin izolyatsiyali)) | 2 300 × 1 000 × 1 545 mm · 851 kg |
| O‘lchamlar (U × E × B) (Ochiq turdagi) | 1 900 × 1 000 × 1 326 mm · 641 kg |
Qiymatlar modelning texnik varag‘idan olingan; to‘liq varaq va katalog sahifasi model sahifasida.
Taklif etilgan konfiguratsiya
- Kontroller: Deep Sea DSE
- 25/22, 33/30, 44/40 kVA zaxira/asosiy
- Dvigatellar YSD490D / Y4100D / Y4105D
Qadoqlash, jo‘natish va eksport hujjatlari
- Transport: Istanbulda zavoddan topshirish (ex works); tashish so‘rov bo‘yicha tashkil etiladi.
- Kabinali agregatlar chet himoyalari bilan strech-plyonkaga o‘raladi; alohida qismlar yashiklarda yoki palletlarda tashiladi.
- Eksport hujjatlari: tijorat hisob-fakturasi, qadoqlash varag‘i, kelib chiqish sertifikati, YeI bojxona rasmiylashtiruvi uchun A.TR harakat sertifikati, zavod sinov hisoboti.
Mijoz, tender va obyekt nomlari ko‘rsatilmaydi; faqat davlat yoziladi. Narxlar va tijorat shartlari e’lon qilinmaydi. Mijoz hujjatlari ulashilmaydi; talablar o‘z so‘zlarimiz bilan qisqacha bayon qilingan.
Texnik topshirig‘ingiz bilan qanday ishlaymiz
- Texnik topshiriq, texnik varaq shakli yoki ehtiyojlar ro‘yxatini yuboring (PDF, Excel, Word yoki xabar).
- Shu ish kunida javob beramiz va yetishmayotgan yoki noaniq bandlarni so‘raymiz.
- Quvvat (prime/standby), kuchlanish, chastota, muhit sharoitlari va avtonomiyani hisoblaymiz, modelni tanlaymiz va band-band muvofiqlik jadvalini tayyorlaymiz. Chetlanishlar va opsiyalar ochiq yoziladi.
- Paketni yuboramiz: taklif, texnik varaq, katalog sahifalari va so‘ralgan shakllar; standart konfiguratsiyalar uchun 24 soat ichida.